Emissivity:
Refer to Appendix
Emissivity of raw materials
.
Set Reference:
Set current spot as reference point. If selected,
all measure result will be relative value to this spot temperature.
Line Measure
There are 2 line measure options: vertical and horizontal.
Horizontal Line Measure
Horizontal Line Measure
Horizontal line is temperature sampling line, and upper-right LCD
corner displays temperature measurement reading on vertical
cursor line intersection. After using Hotkey button select line
measure, press
▲
and
▼
button to adjust sampling line position,
and press
▲
and
▼
button to adjust cursor line position. Press
OK button to enter Attribute Menu. After 2 seconds with no
operation, system will exit to real time Infrared view screen.