background image

SPEED TABLE CV67-CV94 FOR 28 SPEED STEPS

When CV29’s bit 4 is set to “1” it will use the speed table formed by CV67-CV94 to
control speed (motor voltage). It allows you to setup each speed for all 28 speed
steps. First, program CV29 to 18 for short addresses (1-127) or program CV29 to 50
for long addresses (128-9999) to enable speed table control. Then select throttle to
28 speed steps and run your loco at speed step 1. Use program CV on the main to
change CV67’s value (1-255) to adjust step 1’s speed. The kick voltage, CV65 is
only applied when the speed step changes from 0 to 1. You should switch between
0 to 1 many times to check step 1’s speed. When done with CV67, select speed
step 2 and program CV68. CV68’s value must be greater then CV67’s. When done
with CV67-CV94, use read back CV to make sure their values are in increasing
order.
Note: When using MRC Prodigy DCC to program addresses it will automatically
disable the speed table (set CV29’s bit 4 to “0”). Programming CV125 to 1 will
also disable the speed table and re-program CV67-CV94 to a default linear
speed setting.

TROUBLE SHOOTING
Whenever the decoder doesn’t work please use the program track to program
CV# 125 with value 1 to restore some cv’s to factory settings. This should bring
the decoder to life with address #3. You should also clean the track to improve
electrical pickup. Read your DCC system manual to learn how to program and
operate the decoder. For more information about registers/CVs and their
functions, please refer to the NMRA DCC Standard & Recommended Practices,
RP-9.2.2.  This is available directly from the NMRA or their website at
www.nmra.org.

FCC COMPLIANCE

This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions. (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including interfer-

ence that may cause undesired operation.

RETURN PROCEDURE

This decoder carries a 6 month warranty against factory defects. This warranty
does not include abuse, misuse, neglect, improper installation, or any
modifications made to this decoder, including but not limited to the removal of the
NMRA plug if applicable. If it should become necessary to return the decoder for
warranty repair/replacement, please include a copy of the original sales
receipt
. Please include a letter (printed clearly) with your name, address,
daytime phone number, and a detailed description of the problem you are
experiencing. Please also include a check or a money order for $10.50 to cover
return shipping and handling. If the decoder is no longer considered under warranty,
then please include a check or a money order for $50.00 to cover the cost of repair
or replacement and return shipping and handling. Be certain to return the
decoder only.  Any questions regarding Warranty Policy can be directed to
our Customer Service Department by calling 732-225-6360 between the hours

of 8:30am and 6:00pm EST, or by emailing: [email protected]
Send the decoder to:

Model Rectifier Corporation
Attn: Parts & Service
80 Newfield Avenue

Edison, NJ 08837-3817 U.S.A

CV

Description

Range

Default

CV1

Short address

1-127

3

CV2

Start voltage

0-32

0

CV3

Acceleration

0-32

0

CV4

Deceleration

0-32

0

CV5

Top voltage

0-32

32

CV6

Speed curve select (0=linear, 1=slow increase at slow 

speed, 2=fast increase at slow speed)

0-2

0

CV29

Basic configuration

---

2

CV7

Manufacturer version number

---

2

CV8

Manufacturer ID

---

143

CV17

Long address upper byte

192-231

192

CV18

Long address lower byte

0-255

3

CV19

Advanced consist address

0-127

0

CV49

Master volum e control

1-16

16

CV50

Horn type

0-22

13

CV51

Horn volume

0-15

12

CV52

Bell type

0-8

3

CV53

Bell volume

0-15

12

CV54

Bell ring rate

0-50

3

CV55

Diesel rumble volume

0-15

12

CV56

Brake squeal volum e

0-15

7

CV58

Air release volume

0-15

12

CV59

Air pum p volume

0-15

12

CV60

Safety pop valve volume

0-15

12

CV61

Engine cooling fan volum e

0-15

12

CV62

Coupling volume

0-15

12

CV64

Rail wheel clack volume

0-15

12

CV65

kick start voltage

0-63

63

CV67-94

28 speed steps table while CV29.4=1

1-255

linear

CV105

User identification number

0-255

0

CV106

User identification number

0-255

0

CV112

Sand dropping volume

0-15

12

CV113

Back EMF Load control proportinal gain Kp

0-31

20

CV114

Back EMF Load control integral gain Ki

0-31

10

CV115

Auto brake squeal enable/disable

0-1

1(enable)

CV116

Flange squeal volume

0-15

12

CV122

Diesel notch mode, 0=auto-notch3=manual notch

0-3

3

CV123

prime mover type ( 2 types )

3 or 4

3

CV124

Back EMF Load control intensity (0=off)

0-255

160

CV125

Program it to1 will restore some  CV to factory default setting

0-1

0

CV21

When CV21=0, all accessory functions will follow its own 

address. When CV21=1, all functions will follow the consist 

address

---

0

 2011 MODEL RECTIFIER CORPORATION

80 NEWFIELD AVENUE

EDISON, NJ 08837-3817

Printed in USA

HO DC/DCC Synchronized Diesel

Sound Decoder with 28 Accessory

Functions for Atlas S2/S4 Locomotive

Item #0001907

Thank you for purchasing our most advanced DC/DCC 

ALCo

sound decoder. Combined with any DCC System or MRC
Tech 6 Sound Controller, our true live capture digital 

ALCo

sound decoder will

 bring your Atlas S2/S4 loco to life.

  Synchronized diesel prime mover with random

associated locomotive sounds

   Adjustable back EMF load control with ultra slow

speed control

  1.5 amp capacity

  Programmable for either 2-digit (1-127) or 4-digit (1-

9999) addresses

  Programmable start voltage and top voltage

  Programmable acceleration and deceleration rate

  Programmable 14, 28/ 128 speed steps

  Directional lighting, (FO). Sunny White LED’s

included

  Programmable user selectable horns and bells

•  

Read back address and CV value

  28 accessory functions (F1-F28)

  Supports advanced consisting (CV19)

  Supports programming on the main (OPS mode)

  Compatible with NMRA DCC standards

  Complies with part 15 of FCC regulations

  Programmable individual sound volumes

  18mm speaker included

PROGRAMMING
This decoder supports all program mode and read back feature. With MRC Prodigy
Advance DCC you can read its address and CV value.

Отзывы: