background image

Installation instructions and Owner’s Manual

1

UNVENTED NATURAL GAS FIRED ROOM HEATER

Blue Flame Heaters

Plaque Heaters

Model #

Burn Rate

Model #

Burn Rate

MHBF10NG/TSBF10NG

10,000 Btu/hr

MHIR10NG/TSIR10NG

10,000 Btu/hr

MHBF20/NGT/TSBF20NGT

20,000 Btu/hr

MHIR20NGT/TSIR20NGT

20,000 Btu/hr

MHBF30

N

GT/TSBF30NGT

30,000 Btu/hr

MHIR30NGT/TSIR30NGT

30,000 Btu/hr

INSTALLATION INSTRUCTIONS
AND OWNER’S MANUAL

READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a
safe place for future reference. Do not allow anyone who has not read these instructions to
assemble, light, adjust or operate the heater.

MHIR10NG/
TSIR10NG

ENERCO GROUP, INC., 4560 W. 160

TH

 ST., CLEVELAND, OHIO 44135 · 216-916-3000

WARNING:  If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.

- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance

Do not touch an electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

- Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING:  This is an unvented gas-fired heater.  It uses air (oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for Combustion and
Ventilation section on page 3 of this manual.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage.  Refer to this manual for correct installation and operational procedures.  For assistance or additional
information consult a qualified installer, service agency, or gas supplier.

MHIR20NGT/
TSIR20NGT

MHBF30NGT/
TSBF30NGT

MHBF10NG/
TSBF10NG

MHIR30NGT/
TSIR30NGT

MHBF20NGT/
TSBF20NGT

70574     Rev. C    08/05

Содержание HeatStar TSBF20NGT

Страница 1: ...d liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch an electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a ...

Страница 2: ... heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Natural Gas Raw natural gas is odorless An odor making agent is added to natural gas which helps you detect a natural gas leak However the odor added to natural gas can fade So natural gas may be present even though no odor is detected Make certain you read and under stand all warnings Keep this manua...

Страница 3: ...ion 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space 3 Confined Space This heater must not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air The information on pages 3 through 5 will he...

Страница 4: ... Btu hr Total 60 000 Btu hr 4 Compare the maximum Btu hr the space can support with the actual amount of Btu hr used Example 51 800 Btu hr maximum Btu hr the space can support 60 000 Btu hr Actual amount of Btu hr used The space in the above example is a confined space because the actual Btu hr used is more than the maximum Btu hr the space can support You must provide additional fresh air Your op...

Страница 5: ...shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase a CSA AGA certified equipment shutoff valve from your dealer See Accessories page 17 LOCATING HEATER This heater is designed to be mounted on the wall The heater can also be located on a non combustible floor away from a wall by using the floor mounting stands included with the heater If installed on comb...

Страница 6: ...e mounting bracket over a wall stud WARNING Maintain minimum clearances shown in figure 8 If you can provide greater clearances from the floor and joining wall 2 Mark screw locations on wall see figure 7 3 Remove tape and mount bracket from wall Figure 7 Attaching to Wall Stud For attaching mounting bracket to wall studs 1 Drill holes at marked locations using 9 64 drill bit 2 Place mounting brack...

Страница 7: ...d locations using 9 64 drill bit 5 Re place heater onto mounting bracket 6 Place spacers between bottom mounting holes and wall anchor or drilled hole 7 Hold spacer in place with one hand With the other hand insert mounting screw through bottom mounting hole and spacer Place tip of screw in opening of wall anchor or drilled hole 8 Tighten both screws until heater is firmly secured to wall Do not o...

Страница 8: ... heater If sediment trap is not installed or is installed improperly heater may not run correctly IMPORTANT Hold pressure regulator with wrench when connecting it to gas piping and or fittings CHECKING GAS CONNECTIONS WARNING Test all gas piping and connections for leaks after installing or servicing Correct all leaks at once WARNING Never use an open flame to check for a gas leak Apply a mixture ...

Страница 9: ...h type AWG 105o C wire or its equivalent except as indicated WARNING Electrical Grounding Instructions This heater is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a properly grounded three prong receptacle OPERATING YOUR HEATER NON THERMOSTAT MODELS MHIR10NG MHBF10NG TSIR10NG TSBF10NG FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If ...

Страница 10: ... wise to PILOT IGN position This will light pilot If needed gently keep rotating control knob back and forth while depressed until pilot lights 7 Keep control knob depressed in for ten 10 seconds after lighting pilot If pilot goes out repeat steps 4 5 6 and 7 If pilot does not stay lit refer to Troubleshooting pages 14 15 Also contact a qualified service person or gas supplier for repairs If contr...

Страница 11: ...r it call a qualified service technician or gas supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been underwater Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been underwater LIGHTING INSTRUCTIONS 1 STOP Read the all safety information included with and...

Страница 12: ...t levels TO TURN OFF GAS TO APPLIANCE SHUTTING OFF HEATER 1 Turn control knob clockwise to the OFF posi tion 2 Turn off all electrical power to the appliance if servicing is to be preformed 3 Turn off equipment shutoff valve SHUTTING OFF BURNER ONLY PILOT STAYS LIT 1 Turn control knob clockwise to the PILOT IGN position INSPECTING BURNER Check pilot flame pattern and burner flame pattern often PIL...

Страница 13: ... tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This can be done by using a vacuum cleaner in the blow position using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the burner or pilot assem bly In addition the directions that follow sh...

Страница 14: ...ged 1 Burner orifice is clogged 2 Burner orifice diameter to small 3 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Burner orifice is clogged When ignitor button is pressed in there is no spark at pilot ODS pilot lights but flame goes out when control knob is released When ignitor button is pressed in there is a spark at the ODS pilot but no ignition Burner does not light after ODS...

Страница 15: ...e 8 1 This is common with most heaters If noise is excessive contact qualified service person 1 Refer to Fresh Air of Combustion and Ventilation page 3 through 5 Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion Heater produces a cliking ticking noise just after butner is lit or shut off Moisture conden...

Страница 16: ...p 36 915 36 915 36 915 Sides 6 152 10 5 267 10 5 267 Floor min to top of carpet 2 51 2 51 2 51 Fabric flammable objects 36 915 36 915 36 915 BF10NG BF20NGT BF30NGT BTU Available 10 000 20 000 30 000 Type of Gas Natural Gas Only Natural Gas Only Natural Gas Only Ignition Piezo Battery ignitor 1 AA Battery ignitor 1 AA Pressure Regulator Setting 4 5 Inches of Water 4 5 Inches of Water 4 5 Inches of ...

Страница 17: ...y we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealer of this product If they can t supply original replacement part s call Enerco Group Inc s 800 on the back of this manual TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting if so contact Enerco Group Inc s 800 on the back of this manual ACCESS...

Страница 18: ... 39 38 35 16 21 20 1 16 1 16 2 33 2 6 8 26 30 29 17 34 24 3 5 22 3 31 1 31 1 19 13 23 18 10 32 12 3 3 3 1 3 2 3 4 11 1 2 1 4 31 3 31 2 22 2 33 1 22 1 25 9 5 1 3 1 1 27 1 28 1 IR20NGT IR30NGT 4 5 6 15 17 13 14 30 12 2 8 9 7 24 26 23 25 22 1 33 2 22 3 22 1 33 1 20 1 20 2 1 2 1 3 29 1 4 3 1 3 5 1 1 34 3 2 3 6 3 3 11 31 1 31 1 31 2 32 16 1 16 2 16 31 3 27 2 28 2 BF20NGT BF30NGT ...

Страница 19: ...0637 70637 70637 Thermostat Valve Mounting bracket 1 7 70638 70638 70639 70639 Bezel Reflector Front 1 8 70640 70640 70640 70640 Thermostat Valve assembly 1 9 70641 70641 70641 70641 Ignitor Module Mounting Bracket 1 10 70642 70643 Back Plate 1 11 70644 70644 70644 70644 Ignitor Module Battery powered 1 12 70681 70681 70681 70681 Heat Switch Bracket 1 13 70338 70338 70356 70338 Pressure regulator ...

Страница 20: ...677 Burner Plaques 20 3 40 70678 70678 Plaque Gasket 30 4 41 70678 70678 Plaque Gasket 20 3 70680 70680 70680 70680 Power cord 1 70679 70679 70679 70679 Strain relief Grommet 1 70689 70692 Right Burner gas tube 1 70690 70693 Middle burner gas tube 1 70691 70694 Left burner gas tube 1 70695 70695 70696 70696 ODS Gas Tube Assembly 1 70697 70697 70697 70697 Regulator to Thermostat Valve tube Ass y 1 ...

Страница 21: ...BF10NG TSIR10NG TSBF10NG 16 2 16 1 16 21 20 2 40 38 36 20 1 22 2 35 29 1 4 33 1 22 1 1 4 1 2 1 1 1 3 23 2 24 5 10 13 42 3 1 3 3 3 2 3 4 3 5 26 7 8 22 3 IR10NG 33 1 22 1 1 1 3 1 3 3 3 2 3 6 3 5 26 7 8 23 24 13 1 4 1 2 1 3 6 15 14 42 5 22 3 22 2 20 2 16 2 16 1 16 2 20 1 BF10NG 27 2 6 ...

Страница 22: ...Reflector Right Panel 3 6 70317 Reflector Blue Flame Spacer Panel 1 4 70318 70319 Burner Assembly 1 5 70320 70320 Wall Mounting Bracket 1 6 70321 70321 Valve Mounting bracket 1 7 70322 70322 Bezel Reflector Front 1 8 70323 70324 Valve Piezo Assembly 1 10 70325 Back Plate 1 13 70338 70338 Pressure regulator 1 14 70326 Glass 1 15 70327 Glass Mounting Bracket 1 16 70365 70365 ODS Pilot Assembly 1 16 ...

Страница 23: ... Valve Knob 1 70352 Right Burner gas tube 1 70353 Left burner gas tube 1 70354 70354 ODS Gas Tube Assembly 1 70355 70355 Regulator to Thermostat Valve tube Ass y 1 70342 70342 Hardware kit 1 70347 70348 CSA AGA label 1 70349 70349 Gas Instruction decal 1 70350 70350 Inside warning label 1 Item Not Shown Must purchase assembly ITEM PART NO DESCRIPTION QTY IR10NG BF10NG ...

Страница 24: ... warranty does not apply to parts that are not in original condition because of normal wear and tear of parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such costs related to repairing a defective heater will be the responsibility of the owner TO THE FU...