Mr. Heater Grand Teton PS20WTS Скачать руководство пользователя страница 14

14

Operating Instructions and Owner’s Manual

Grand Teton Wood Pellet Fire Stove

OPERATING PRECAUTIONS

 WARNING: HOT WHILE IN OPERATION. DO 

NOT TOUCH THE STOVE. KEEP CHILDREN, 
CLOTHING AND FURNITURE AWAY. 
CONTACT MAY CAUSE SKIN BURNS.

 CAUTION: ENSURE THAT THE FIREPOT AND 

THE PAN UNDERNEATH ARE CLEAN AND IN 
THE PROPER OPERATING POSITION BEFORE 
USING THE STOVE.

 WARNING: NEVER USE GASOLINE, 

GASOLINE-TYPE LANTERN FUEL, KEROSENE, 
CHARCOAL LIGHTER FLUID, OR SIMILAR 

LIQUIDS TO START OR ‘FRESHEN UP’ A FIRE 

IN THIS HEATER. KEEP ALL SUCH LIQUIDS 
WELL AWAY FROM THE HEATER WHILE IT IS 
IN USE. 

PAINT CURING

To allow the paint to bond durably to the stove, start 
by running the stove on P1 Maximum Power for at 
least 30 minutes. Provide cross ventilation to eliminate 
odors or smoke cause by this curing process.

OPERATING PROCEDURE: TURN ON STOVE

NOTE: 

If the display screen indicates that the 

stove is “Switching Off” the stove can not 

be interrupted. The Display Message will 
highlight to indicate that the state will not be 

changed. Only once the “Switching Off” cycle 

has finished and the exchanger has cooled 
can the stove be turned back on again.

1. Make sure that seals on the ash drawer and door 

are in good condition. If the stove has never been 
run before, add a handful of pellets directly to the 
firepot. Close the ash drawer and doors securely, 
and check that all side panels are all properly 
installed.

NOTE: 

DO NOT USE GRATES, IRONS, OR ANY 
OTHER METHODS OF SUPPORTING WOOD 
PELLET FUEL. ONLY THE FIREPOT SPECIFIC 
TO YOUR MODEL OF STOVE MAY BE USED.

2. Open the hopper. Ensure that there are a 

sufficient number of pellets to satisfy your heating 
requirements. Close the hopper.

3. Press the power button. The stove will begin to 

automatically progress through the following stages:

• 

Cleaning Cycle: The firepot draws dust, ash, & 
remenants out.

• 

Feeding Cycle: Pellets will be transported from the 
Pellet Hopper into the fire pot by the auger. This 
can take 5 to 15 minutes depending on the model 
of stove.

• 

Lighting Cycle: The electrically powered hot surface 
igniter will power on for 8 minutes and begin 
combustion of the pellets in the firepot. The heater 
will remain in the Lighting Cycle until the exhaust 
smoke reaches a designated temperature.

• 

Stabilization Cycle: The heater adjusts to fine tune 
the stove output to the desired temperature. This 
can take a few minutes

4. The stove has been successfully turned on.

OPERATING PROCEDURE: TURN OFF STOVE

NOTE: 

THE STOVE MAY BE TURNED OFF, 
REGARDLESS OF WHAT CYCLE THE DISPLAY 
SCREEN INDICATES THAT THE STOVE IS IN, 
BY DEPRESSING AND HOLDING THE POWER 
BUTTON FOR TWO SECONDS. ONCE THE 
DISPLAY SCREEN INDICATES THAT THE 
STOVE IS IN THE STABILIZATION CYCLE 
PRESS THE POWER BUTTON AGAIN. THE 
STOVE WILL ENTER THE COOLING CYCLE, 
STATED ON THE DISPLAY SCREEN.

 CAUTION: AFTER THE COOLING CYCLE THE 

STOVE AUTOMATICALLY BEGINS 
THE PROCESS OF CYCLING ON.

1. Press the power button. The stove will begin to 

automatically progress through the following stages:

• 

Switching Off: Any remaining fuel in the firepot 
will continue to burn and produce heat and 
flame. After 5 to 8 minutes the firepot ought to 
be devoid of fuel. The heat exchanger may then 
begin to cool off.

• 

Goodbye: The final message from the display 
screen to designate that the stove has cooled.

2. The stove has been successfully turned off.

OPERATION WITH AN ELECTRICAL GENERATOR

This stove is designed to have the option of being 
powered by an electrical generator, though not 

all electrical generator’s may be compatible with 

this stove. Consult the information regarding your 

generator’s electrical regulator and make sure that 

it meets the electrical requirements of this stove, as 
stated on page 3. 

Содержание Grand Teton PS20WTS

Страница 1: ...LLATION TO DETERMINE ANY NEED TO OBTAIN A PERMIT OBSERVE ALL LOCAL BUILDING CODES OPERATING INSTRUCTIONS AND OWNER S MANUAL Model PS20WTS READ INSTRUCTIONS CAREFULLY Please read this entire manual bef...

Страница 2: ...H AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE STOVE AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE STOVE IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLE...

Страница 3: ...00 Pellet Consumption Rate High LBS HR kg HR 3 75 1 70 Pellet Consumption Rate Medium LBS HR kg HR 1 72 0 78 Pellet Consumption Rate Low LBS HR kg HR 1 70 0 77 Stove Efficiency 76 Heat Output Rate BTU...

Страница 4: ...OORING MATERIAL on page 6 Manufactured venting of 3 80mm in diameter of type L or PL which is listed to UL 641 ULC S609 Standard for 650 C Factory Built Chimneys or ULC ORD C441 Install per chimney ma...

Страница 5: ...E FLU WITH HEADACHE DIZZINESS AND OR NAUSEA IF YOU HAVE THESE SIGNS STOVE MAY NOT BE WORKING PROPERLY GET FRESH AIR AT ONCE HAVE STOVE SERVICED SOME PEOPLE PREGNANT WOMEN PERSONS WITH HEART OR LUNG DI...

Страница 6: ...of clearance from the rear to the nearest body Vertical runs of vent pipe must be at least 3 77 mm from any wall Finally the area which the wood pellet fire stove is installed shall have a floor to ce...

Страница 7: ...e stove Once any necessary assembly of the display panel screen is complete you may briefly plug your stove in to make sure that it functions properly before proceeding with installation Unplug the st...

Страница 8: ...it will not come into contact with the stove s surface FRESH AIR AND VENTILATION REQUIREMENTS When deciding the location of the stove ensure that the space will always have a source of fresh air avai...

Страница 9: ...actory Built Residential Type and Building Heating Appliance UL 103 A International Conference of Building Officials ICBO standards for solid fuel Stoves code approved masonry chimney VENT TERMINATION...

Страница 10: ...annels separated from combustibles by a minimum of 6 inches 152 mm of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 24 gauge in thickness Fig...

Страница 11: ...red and can not be moved tipped or have ventilation seals compromised The stove must be provided a permanently ducted source of outside air to support combustion which meets the following requirements...

Страница 12: ...ites of chimney manufacturers will be able to provide stove pipe that is rated to these standards This listing indicates that the Chimney is rated for high temperatures up to 2100 F 1 149 C Only use c...

Страница 13: ...he pellet sediment debris at the bottom of the pellet container Store pellets in sacks made of environmentally neutral or biologically degradable plastic or from paper 2 3 layers similar to cement pac...

Страница 14: ...hrough the following stages Cleaning Cycle The firepot draws dust ash remenants out Feeding Cycle Pellets will be transported from the Pellet Hopper into the fire pot by the auger This can take 5 to 1...

Страница 15: ...1 Download the Smart Stove app by NHHATC Step 2 Open the Smart Stove app The app opens by default to the Register screen Click on the Register button Step 3 Enter your email address in the Email field...

Страница 16: ...wo ECO settings which can be selected which will conserve wood pellets while maintaining the desired temperature Pressing the ECO button will allow you to toggle whether a specific eco setting is enab...

Страница 17: ...the exhaust pipe temp the hopper protection temp and number of run hours etc Settings Press to enter User Settings Menu Figure 17b On this menu you may select F or C ECO Mode see Wi Fi controls for e...

Страница 18: ...y day Whichever is more frequent Ash Drawer After 50 bags of wood pellets Passageways After 100 bags of wood pellets Blower After 100 bags of wood pellets CLEANING FIRE POT PAN CAUTION IF STOVE IS INT...

Страница 19: ...ormance and failure to remove creosote may result in a dangerous chimney fire CLEANING PIPE CLEANERS This model features pipe cleaners attached which can be pumped in order to scrape within the passag...

Страница 20: ...of the gasket gutter 4 Press the beginning of the replacement gasket into the most up and most left position of the prepared gasket gutter 5 Continue pressing the replacement gasket clockwise along th...

Страница 21: ...perature limiter is installed on the bottom of the hopper If this sensor is exposed to temperatures higher than 158 degrees then the stove is shut off 3 Vent Pipe High Temperature Thermostat A high te...

Страница 22: ...using low quality fuel in fire pot 2 Check that the firepot is sitting in the holder correctly and that the igniter is not obstructed 3 Check that the exhaust gas temperature sensor switch beside the...

Страница 23: ...itch Power Cord disconnected 1 Press power cord tightly into the heater 2 Ensure that the wall socket is delivering 120 Volts Fuse is blown Replace the fuse The blower does not turn on during Cleaning...

Страница 24: ...eding speed After the fire has started the stove turns off 15 minutes later The pellet hopper is low on fuel Check that the pellet hopper has a sufficient amount of fuel The auger is not operating 1 U...

Страница 25: ...Replace the 30 o C temperature switch The fire extinguishes and the power shuts off continued Requested temperature has been reached This is normal ECO mode behavior The stove will automatically swit...

Страница 26: ...sensor NO NC NO NC C Wifi Pellet Test Vaccum switch Display panel Blower Combustion Fan Auger motor Igniter GND FUSE Power GND N L Shorting Switch NOTE IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE...

Страница 27: ...16 66674 Door Hinge NO PART NUM DESCRIPTION 17 66608 Igniter 18 66607 Combustion Blower 19 66675 Circulation Blower 20 66676 Rear cover 21 66677 Side Seal Cover 22 66678 Side Seal Gasket 23 66679 Clea...

Страница 28: ...im Also supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no o...

Страница 29: ...RESPECTEZ TOUS LES CODES DE LA CONSTRUCTIONS LOCAUX GUIDE DU PROPRI TAIRE ET INSTRUCTIONS D UTILISATION No de mod le PS20WTS LIRE LES INSTRUCTIONS ATTENTIVEMENT Veuillez lire le pr sent manuel au com...

Страница 30: ...DE CONSTRUCTION LE CARTON OU LE PAPIER UNE DISTANCE S CURITAIRE DU PO LE SELON LES RECOMMANDATIONS DU MANUEL NE JAMAIS UTILISER LE PO LE DANS UN LIEU AYANT OU QUI A POSSIBILIT D AVOIR DES MATI RES VOL...

Страница 31: ...onsommation de grenailles sur r glage haute kg h lb h 3 75 1 70 Taux de consommation de grenailles sur r glage moyen kg h lb h 1 72 0 78 Taux de consommation de grenailles sur faible kg h lb h 1 70 0...

Страница 32: ...Tournevis Phillips manuel ou lectrique Localisateur de montants Fil plomb Scie sauteuse Silicone haute temp rature ou scellant haute temp rature ou ruban de conduit de fum e haute temp rature Protecti...

Страница 33: ...ES TOURDISSEMENTS ET OU NAUS ES SI VOUS SOUFFREZ DE CES SYMPT MES LE PO LE POURRAIT EN TRE LA CAUSE EN RAISON DE MAUVAIS FONCTIONNEMENT OBTENEZ DE L AIR FRAIS RESPIRER SUR LE CHAMP FAITES UN ENTRETIE...

Страница 34: ...gagement minimum de 229 mm 9 po de chaque cot de l appareil Qu il y ait un d gagement minimum de 239 mm 9 4 po l arri re de l appareil Que le tuyau d chappement vertical soit d gag d au moins 77 mm 3...

Страница 35: ...tout assemblage requis du panneau d affichage vous pouvez brancher votre po le temporairement pour vous assurer du fonctionnement de l afficheur avant de continuer l installation Apr s avoir confirmer...

Страница 36: ...le EXIGENCES D AIR FRAIS ET D A RATION Lorsque vous d cidez de la localisation du po le assurez vous que l aire sera toujours approvisionn e d air frais Un manque d air pourrait appauvrir tous les ap...

Страница 37: ...de ma onnerie certifi e ICBO International Conference of Building Officials pour les po les combustible solide CAPUCHON D VENT Installer l vent d chappement en respectant les distances de d gagement s...

Страница 38: ...e et la section de chemin e support e et fix e deux montants d acier de calibre minimum no 24 La quincaillerie de fixation de la section de chemin e ne doit pas perforer sa paroi interne TECHNIQUES DE...

Страница 39: ...e fa on compromettant une a ration ad quate Une canalisation permanente d admission d air frais pour entretenir la combustion devra tre install e en r pondant aux exigences suivantes La canalisation d...

Страница 40: ...on domiciliaires les quincailleries et les magasins de fournitures CVCA ainsi que les sites Web de fabricants de chemin es pourront vous fournir des tuyaux de po le isol s r pondant ces normes Cet enr...

Страница 41: ...sacs deux ou trois couches de papier comme ceux des sacs de ciment ou faits de produits synth tiques biologiquement d gradables et neutres au point de vue environnemental L utilisation de grenailles...

Страница 42: ...DE COMBUSTION SEUL LE POT LUI M ME PARTICULIER VOTRE MOD LE DE PO LE DOIT TRE UTILIS 2 Ouvrez la tr mie Assurez vous qu elle est suffisamment remplie Refermez la tr mie 3 Appuyez sur le bouton d alime...

Страница 43: ...o le peut tre surveill contr l et programm en utilisant l application Smart Stove par NHHATC qui est disponible votre magasin d applications pour les plateformes iOS ou Android tape 1 T l chargez l ap...

Страница 44: ...de bois tout en maintenant la temp rature d sir e L actionnement du bouton ECO permettra de basculer entre ces modes ou de les ignorer ECO 1 Le po le s teint lorsque la temp rature d sir e est atteint...

Страница 45: ...p rature de protection de la tr mie et le nombre d heures de fonctionnement etc Param tres Appuyez sur pour acc der au menu des param tres utilisateur Figure 17b Dans ce menu vous pouvez s lectionner...

Страница 46: ...Selon la premi re ventualit Tiroir de cendre Apr s 50 sacs de grenailles de bois Canalisations internes Apr s 100 sacs de grenailles de bois Ventilateur Apr s 100 sacs de grenailles de bois NETTOYAGE...

Страница 47: ...uvent restreindre le d bit de gaz qui affectera la performance du po le et ne pas retirer la cr osote pourrait r sulter en un dangereux feu de chemin e NETTOYAGE ESSUIES PIPE Certains mod les ont des...

Страница 48: ...t teintes et que le po le est froid 2 Retirer le joint us et nettoyer le sillon d insertion 3 Appliquer un mince film de ciment joint d tanch it r sistant aux temp ratures lev es l int rieur du sillon...

Страница 49: ...lac e sous le fond de la tr mie Si ce capteur est expos une temp rature d passant 70 C 158 F le po le sera teint 3 Thermostat de temp rature lev e dans le tuyau d chappement Une protection de temp rat...

Страница 50: ...upport et qu il n y a pas d obstruction devant l allumeur 3 S assurer que le capteur de temp rature de gaz d chappement adjacent au ventilateur de combustion est en bon tat et n a pas subi de dommage...

Страница 51: ...ns rer fond le cordon d alimentation dans le po le 2 S assurer que la prise murale fournit une tension de 120 V Le fusible est grill Remplacer le fusible Le ventilateur ne tourne pas durant les cycles...

Страница 52: ...le coincement 3 S assurer que la vis de fixation de la tari re au moteur est bien serr e Le thermostat de temp rature de 30 C s est d clench 1 S assurer que les fils du thermostat sont bien connect s...

Страница 53: ...esse de grenailles Le thermostat de temp rature de 30 C s est d clench 1 S assurer que les fils du thermostat sont bien connect s 2 Remplacer le thermostat de 30 C La combustion s arr te et le po le i...

Страница 54: ...ent NO NC NO NC C Wifi Test de granul s Pressostat Panneau d affichage Ventilateur Ventilateur de combustion Moteur de tari re Allumeur GND FUSIBLE Alimmentation GND N L Court circuit Changer REMARQUE...

Страница 55: ...aule droite 12 66671 Nettoyage des tuyaux 13 66664 Carte m re 14 66673 Pot de feu 15 66628 Commutateur de vide 16 66674 Charni re de porte No No de pi ce DESCRIPTION 17 66608 Allumeur 18 66607 Souffle...

Страница 56: ...ls concernant la demande de compensation Veuillez galement nous indiquer la date d achat ainsi que les nom et adresse du d positaire o vous avez achet votre produit Ce qui suit est la description comp...

Отзывы: