www.mqcon.com
- 7 -
Basic setting interface
Item
Description
wheel
Motor tire diameter, fixed in inches, independent of other "system"
settings
battery
Select according to the battery voltage currently used
start password
This menu can't be entered or the button is invalid.
advance
Advanced settings, submenu entry
factory
Restore factory settings parameters
Advance setting interface
Item
Description
assist level
PAS mode speed split: There are 3, 5 and 9 modes; please select 5 mode
speed limit
the controller use the computer or app settings instead of the LCD settings.
current limit
power limit
poles in motor
Enter the number of magnetic steel sheets. For example, 23 poles motor,
enter 46 here.
magnet disk
PAS Speed magnets, the controller ignores the LCD settings
start mode
zero start: the throttle can drive the motor at the zero speed of the motor;
non-zero start: Only when the motor speed is not 0, the throttle can drive
the motor
drive mode
0: only PAS is valid 1: only the throttle is valid; 2: pas and throttle are valid
start sensor
after a few laps (set value), the PAS begins to function.
start strength
controller currently ignore meter settings
throttle level
controller currently ignore meter settings
clockwise
controller currently ignore meter settings
throttle 6km
controller currently ignore meter settings
key antijam
controller currently ignore meter settings
assist forward
controller currently ignore meter settings
Содержание H6