DCA-800SSK (STD) — OPERATION AND PARTS MANUAL — REV. #4 (06/03/10) — PAGE 17
Outdoor Installation
Install the generator in a area that is free of
debris
,
bystanders
, and
overhead obstructions
. Make sure the
generator is on secure level ground so that it cannot slide or
shift around. Also install the generator in a manner so that
the exhaust will not be discharged in the direction of nearby
homes.
The installation site must be relatively free from moisture
and dust. All electrical equipment should be protected from
excessive moisture. Failure to do will result in deterioration
of the insulation and will result in short circuits and grounding.
Foreign materials such as dust, sand, lint and abrasive
materials have a tendency to cause excessive wear to engine
and alternator parts.
Indoor Installation
Exhaust gases from diesel engines are extremely poisonous.
Whenever an engine is installed indoors the exhaust fumes
must be vented to the outside. The engine should be installed
at least two feet from any outside wall. Using an exhaust
pipe which is too long or too small can cause excessive
back pressure which will cause the engine to heat excessively
and possibly burn the valves.
Mounting
The generator must be mounted on a solid foundation (such
as concrete) and set firmly on the foundation to isolate
vibration of the generator when it is running. The generator
must set at least 6 inches above the floor or grade level (in
accordance to NFPA 110, Chapter 5-4.1).
DO NOT
remove
the metal skids on the bottom of the generator. They are to
resist damage to the bottom of the generator and to maintain
alignment.
Generator Grounding
To guard against electrical shock and possible damage to
the equipment, it is important to provide a good
EARTH
ground.
Article 250 (Grounding) of the National Electrical Code (NEC)
provides guide lines for proper grounding and specifies that
the cable ground shall be connected to the grounding system
of the building as close to the point of cable entry as
practical.
NEC articles 250-64(b) and 250-66 set the following
grounding requirements:
1. Use one of the following wire types to connect the
generator to earth ground.
a. Copper - 10 AWG (5.3 mm
2
) or larger.
b. Aluminum - 8 AWG (8.4 mm
2
) or larger.
2. When grounding the generator (Figure 3) connect the
ground cable between the lock washer and the nut on
the generator and tighten the nut fully. Connect the other
end of the ground cable to earth ground.
3. NEC article 250-52(c) specifies that the earth ground
rod should be buried aminimum of 8 ft. into the ground.
When connecting the generator to
any buildings electrical system
ALWAYS
consult with a licensed
electrician.
DCA-800SSK — INSTALLATION
NOTE
Pay close attention to ventilation when operating the
generator inside tunnels and caves. The engine exhaust
contains noxious elements. Engine exhaust must be routed
to a ventilated area.
CAUTION - EXHAUST HAZARD
Содержание WhisperWatt DCA800SSK
Страница 2: ...PAGE 2 DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 Diesel engine exhaust and some of ...
Страница 3: ...DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 PAGE 3 ...
Страница 7: ...DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 PAGE 7 NOTE PAGE ...
Страница 23: ...DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 PAGE 23 DCA 800SSK OPERATION AND SAFETY DECALS ...
Страница 24: ...PAGE 24 DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 DCA 800SSK OPERATION AND SAFETY DECALS ...
Страница 25: ...DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 PAGE 25 DCA 800SSK OPERATION AND SAFETY DECALS ...
Страница 72: ...PAGE 72 DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 GENERATOR ASSY DCA 800SSK GENERATOR ASSY ...
Страница 74: ...PAGE 74 DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 DCA 800SSK GENERATOR ASSY GENERATOR ASSY ...
Страница 78: ...PAGE 78 DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 DCA 800SSK CONTROL BOX ASSY CONTROL BOX ASSY ...
Страница 80: ...PAGE 80 DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 DCA 800SSK CONTROL BOX ASSY CONTROL BOX ASSY ...
Страница 86: ...PAGE 86 DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 DCA 800SSK OIL DRAIN ASSY OIL DRAIN ASSY ...
Страница 94: ...PAGE 94 DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 DCA 800SSK BATTERY ASSY BATTERY ASSY ...
Страница 96: ...PAGE 96 DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 MUFFLER ASSY DCA 800SSK MUFFLER ASSY ...
Страница 98: ...PAGE 98 DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 FUEL TANK ASSY DCA 800SSK FUELTANK ASSY ...
Страница 112: ...PAGE 112 DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 DCA 800SSK RUBBER SEALS ASSY RUBBER SEALS ASSY ...
Страница 119: ...DCA 800SSK STD OPERATION AND PARTS MANUAL REV 4 06 03 10 PAGE 119 NOTE PAGE ...