PAGE 32 — DCA-300SSK SERIES — PARTS AND OPERATION MANUAL (STD) — REV. #4 (03/27/06)
Lubrication Oil
Fill the engine crankcase with lubricating oil through the filler
hole, but
DO NOT
overfill. Make sure the generator is level.
Also verify that the oil level is maintained between the two
notches (Figure 29) on the dipstick. See Table 11 for proper
selection of engine oil.
DCA-300SSK SERIES — PRE-SETUP
Figure 29. Engine Oil Dipstick
When checking the engine oil, be sure to check if the oil is
clean. If the oil is not clean, drain the oil by removing the oil
drain plug, and refill with the specified amount of oil as outlined
in the
Komatsu Engine Owner's Manual.
Oil should be
warm before draining.
Circuit Breakers
To protect the generator from an overload, a 3-pole, 800 amp,
main
circuit breaker is provided to protect the UVWO output
terminals from overload. In addition two single-pole, 20 amp
GFCI
circuit breakers are provided to protect the GFCI
receptacles from overload. Three 50 amp
load
circuit breakers
have also been provided to protect the auxiliary receptacles
from overload. Make sure to switch
ALL
circuit breakers to
the "
OFF
" position prior to starting the engine.
z
API Service Classification CH-4
z
API Service Classification CG-4
z
API Service Classification CF-4
z
ACEA Specification E3
z
ACEA Specification E2
Other types of motor oils may be substituted if they meet
the following requirements:
Figure 30. Double Fuel Tank System
REFILLING THE FUEL SYSTEM
The DCA300SSK series generators may (if equipped with a
trailer or skid) have a
double fuel tank system
(Figure 30),
which consists of an
internal
generator fuel tank, and a
trailer mounted
fuel tank. It is also possible the generator
can be equipped with a
skid mounted
fuel tank (Figure 31).
The skid type fuel system does not use the internal generator
fuel tank.
Use the instructions in this section that applies to your type
of fuel tank system.
ALWAYS
fill the fuel tank with clean and fresh
#2 diesel
fuel.
DO
NOT
fill the fuel tanks beyond their capacities.
Pay attention to the fuel tank capacity when replenishing
fuel. The fuel tank cap must be closed tightly after filling.
Handle fuel in a safety container. If the container does not
have a spout, use a funnel. Wipe up any spilled fuel
immediately.
li
O
r
o
t
o
M
d
e
d
n
e
m
m
o
c
e
R
.
1
1
e
l
b
a
T
e
g
n
a
R
e
r
u
t
a
r
e
p
m
e
T
li
O
e
p
y
T
7
7
o
r
e
t
a
e
r
g
d
n
a
F
5
2
(
o
)
r
e
t
a
e
r
g
d
n
a
C
0
4
E
A
S
r
o
0
4
-
W
5
1
E
A
S
2
3
o
7
7
o
t
F
o
F
0
(
o
5
2
o
t
C
o
)
C
0
3
E
A
S
r
o
0
3
-
W
0
1
E
A
S
2
2
-
o
2
3
-
o
t
F
o
F
0
3
-
(
o
0
C
o
)
C
0
1
E
A
S
r
o
0
3
-
W
0
1
E
A
S
Fuel spillage on a
hot
engine can cause a
fire
or
explosion
.
If fuel spillage occurs, wipe up the spilled fuel completely
to prevent fire hazards.
NEVER
smoke around or near the
generator.
DANGER - EXPLOSION/FIRE HAZARDS
Fuel Check
ONLY properly trained personel
who have read and
understand this section should refill the fuel tank system.
CAUTION - REFUELING THE GENERATOR
Содержание Whisperwatt DCA-300SSK
Страница 2: ...PAGE 2 DCA 300SSK SERIES PARTS AND OPERATION MANUAL STD REV 4 03 27 06 ...
Страница 43: ...DCA 300SSK SERIES PARTS AND OPERATION MANUAL STD REV 4 03 27 06 PAGE 43 NOTE PAGE ...
Страница 92: ...PAGE 92 DCA 300SSK SERIES PARTS AND OPERATION MANUAL STD REV 4 03 27 06 DCA 300 SSK BATTERY ASSY BATTERY ASSY ...
Страница 94: ...PAGE 94 DCA 300SSK SERIES PARTS AND OPERATION MANUAL STD REV 4 03 27 06 DCA 300SSK MUFFLER ASSY MUFFLER ASSY ...
Страница 110: ...PAGE 110 DCA 300SSK SERIES PARTS AND OPERATION MANUAL STD REV 4 03 27 06 DCA 300SSK RUBBER SEAL ASSY RUBBER SEAL ASSY ...
Страница 112: ...PAGE 112 DCA 300SSK SERIES PARTS AND OPERATION MANUAL STD REV 4 03 27 06 OIL PIPING ASSY DCA 300SSK OIL PIPING ASSY ...
Страница 121: ...DCA 300SSK SERIES PARTS AND OPERATION MANUAL STD REV 4 03 27 06 PAGE 121 NOTE PAGE ...