background image

ELECTRIC WALK-BEHIND TROWEL — SERVICE BULLETIN TR20190823 — REV. #1 (10/16/19) — PAGE 2

WORK SAFELY!

Only a qualified service technician with proper training 

should perform this procedure.

 Follow all shop safety 

rules while performing this procedure.

REQUIRED TOOLS

 

„

Flat-head screwdriver

 

„

Phillips-head screwdriver

 

„

Wire strippers/crimpers/cutters

PREPARATION

Place the trowel on secure, level ground in an area free of 

dirt and debris. Make sure the motor is turned 

OFF

.

EXISTING PLUG REMOVAL

1.  Remove the two screws securing the switch box cover 

to the front of the main switch box (Figure 2). Keep the 

screws for later.

Figure 2. Remove Main Switch Box Cover

2.  Open the main switch box and disconnect the three 

power cable wires (Figure 3).

MAIN SWITCH

BOX COVER

REMOVE

2 SCREWS

Figure 3. Disconnect Power Cable Wires

3.  Remove the two small screws (Figure 4) securing the 

existing power cable fitting to the main switch box.

Figure 4. Remove Existing Power  

Cable Assembly

OF

F

O

N

L3

GND

L1

DISCONNECT

3 WIRES

MAIN

SWITCH BOX

EXISTING

POWER CABLE

REMOVE

2 SCREWS

REMOVE CABLE

AND FITTING

Содержание J36E2

Страница 1: ...UAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES To find the latest revision of this publication visit our website at www multiquip com MODEL J36E2 WALK BEHIND TROWEL 2 HP ELECTRIC MOTOR S N LE0118039 AND BELOW Revision 2 01 31 18 PN 23814 ...

Страница 2: ...LE0118039 and below it will need to be rewired for 230 volt operation Please see the attached Safety Warning and Service Bulletin for details NOTICE For current operation and or parts information for the J36E2 Walk Behind Trowel go to www multiquip com and refer to the operation and parts manuals for the J36E2 S N LE0118040 and above ...

Страница 3: ...ectric switch failure resulting in the failure of the Operator Presence ON OFF Lever Switch However we believe it is necessary to bring this to your attention as a safety precaution If you own any of these models listed above use the trowel only in its 230 volt configuration and for 230 volt operation only DO NOT CONTINUE OPERATING THE TROWEL USING 115 VOLT POWER Conversion rewiring to 230 volt op...

Страница 4: ...llowance 1 0 hour total flat rate for rewire of unit from 115 VAC to 230 VAC Your prompt attention to this matter is appreciated If you have questions please contact the MultiquipTechnical Support Department at 800 478 1244 or techsupport multiquip com We appreciate your business and apologize for any inconvenience this creates Our goal remains to supply you with top quality equipment and superior...

Страница 5: ...ator Presence ON OFF Lever Switch from operating as intended Failure of the switch could result in a runaway trowel and SERIOUS INJURY and or property damage Solution If you own any of these models listed above use the trowel only in its 230 volt configuration and for 230 volt operation only DO NOT CONTINUE OPERATINGTHETROWEL USING 115 VOLT POWER Conversion rewiring to 230 volt operation should be...

Страница 6: ... the motor is turned OFF EXISTING PLUG REMOVAL 1 Remove the two screws securing the switch box cover to the front of the main switch box Figure 2 Keep the screws for later Figure 2 Remove Main Switch Box Cover 2 Open the main switch box and disconnect the three power cable wires Figure 3 MAIN SWITCH BOX COVER REMOVE 2 SCREWS Figure 3 Disconnect Power Cable Wires 3 Remove the two small screws Figur...

Страница 7: ...y wires and crimp See Figure 5 0 25 230V PIGTAIL ASSEMBLY P N 30718 RING TERMINAL P N 30096 3 Connect the three pigtail assembly wires inside the main switch box as shown in Figure 6 Figure 6 Install New Power Cable 4 Finish installing the 230V pigtail assembly P N 30718 by inserting the push on liquid tight connector into the open hole on the main switch box Make sure the connector is fully seate...

Страница 8: ...Connect the red and yellow wires from the motor with the white wire from the handle using a crimp sleeve P N 19687 and splice cap insulator P N 19688 See Figure 7 3 Connect the yellow black wire from the motor with the black wire from the handle using a pre insulated crimp 16 12 AWG wire nut P N 34938 See Figure 7 4 Use the remaining pre insulated crimp 16 12 AWG wire nut P N 34938 to cap off the ...

Страница 9: ...ELECTRIC WALK BEHINDTROWEL SERVICE BULLETINTR20190823 REV 1 10 16 19 PAGE 5 NOTES ...

Страница 10: ...C Multiquip Inc and the MQ logo are registered trademarks of Multiquip Inc and may not be used reproduced or altered without written permission All other trademarks are the property of their respective owners and used with permission The information and specifications included in this publication were in effect at the time of approval for printing Illustrations descriptions references and technica...

Отзывы:

Похожие инструкции для J36E2