EVKT-MACOM
– MAGALPHA COMMUNICATION KIT
EVKT-MACOM
www.MonolithicPower.com
14
3/1/2018
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2018 MPS. All Rights Reserved.
Figure 24: Macom App Registers overview feature
Angle Readback
Figure 25: Macom App Angle Readback
Angle Readback
Update Firmware
Update the LPC-Link2 microcontroller firmware. To perform a firmware update, click on this
feature and follow the step-by-step instructions displayed on the firmware update wizard.
Full Screen
Switch On/Off Full Screen Mode
Feature Name
Description
Raw input
Measured angle value coded on 16-bits (0 to 65535) and in degree (0 to 360)
Resolution
Gives 6σ resolution in bit (n) and 3σ resolution in degree (m). Which means that 99.7% of the
measurement performed on this sensor will have the same
n
MSB
bits
and will be within ±
m
degrees
from the latest angle measurement.