User Guide
MP5416 Evaluation Kit (EVKT-5416)
MP5416 Evaluation Kit User Guide Rev 1.31
MonolithicPower.com
14
10/14/2019
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2019 MPS. All Rights Reserved.
Figure 20
1
. Install the correct USBXpress “.exe” file
Choose either 32 bit or 64 bit operating system.
32-bit: USBXpressInstaller_x86.exe
64-bit: USBXpressInstaller_x64.exe
2. Connect the EVKT-USBI2C-02 Dongle to the PC with the USB cable.
No Supply
The PMIC’s input pin has an under-voltage lockout (UVLO) detection circuit. If the input voltage (AVIN)
is lower than the UVLO rising
threshold, the PMIC’s functions are disabled.
Shutdown Event
If the PMIC detects that the input voltage is lower than the UVLO falling threshold (enter no supply state)
or over-temperature protection is triggered (enter power off state), the PMIC switches to no supply state
or power-off state, regardless of the current state.
Thermal Recovery
If the MP5416 is in a power-off state due to the die temperature exceeding the thermal protection
threshold, the PMIC enters a power-
on sequence when the die’s temperature decreases.
Shutdown Sequence
When the input voltage is lower than the UVLO falling threshold or the IC is over-temperature, the PMIC
enters the shutdown sequence directly.
Содержание EVKT-5416