EVHR2000-S-00A –FLUORESCENT LAMP HB DRIVER WITH PFC
NOTICE:
The information in this document is subject to change without notice. Please contact MPS for current specifications.
Users should warrant and guarantee that third party Intellectual Property rights are not infringed upon when integrating MPS
products into any application. MPS will not assume any legal responsibility for any said applications.
EVHR2000DS-00A Rev.1.01
www.MonolithicPower.com
14
5/27/2013
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2013 MPS. All Rights Reserved.
QUICK START GUIDE
1. Connect the fluorescent lamp to EVB’s connector ‘P2’, one side of terminals to ‘1’ and ‘2’ and the
other side of terminals to ‘3’ and ‘4’;
2. Preset the AC power supply to 198V
≤
AC input
≤
264V; turn off the AC power supply.
3. Connect the AC power supply to ‘P1’;
4. Turn on the AC power supply, the lamp should be ignited.