MPPT M4860ADS Скачать руководство пользователя страница 6

load

 

work

 

mode

1:manual mode

K 3

K 1

K 2

3

K1

K2

K 1

K 2

K 1

K 2

Single period real time control

 

Set load working mode

There are 5 load working modes: 
1: manual mode:  press the K4 button  to turn the load output on or off. 
2: pure light control mode:  the voltage of the solar panel is detected automatically, the load is turned on at dark and the load is 
    turned off at dawn. 
3: light c time control mode: the load starts the light control, and the load closing time is set by the user. 

4: single  real time control: Users can set real-time time to enable and close the load. 
5: double-time real time control : , users can set two real-time periods to output and turn off the load of the controller, such as 

    8: 00 a.m. to 10:00 and 2: 00 p.m. to 4: 00 p.m.

Set operation instructions: 

Manual mode and pure light control

 mode do not need to set the time, and the other three modes need to set the working time. 

The operation are as follows: 

Light c time control

: Turn the page to  the load working mode to light c time control interface (mode 3), press K3 key, 

"SET" and "H" font flash, press K1 or K2 key to set the number of hours, the setting is finished. 
Then press K3 key, "SET" and "M" font flash, press K1 or K2 key to set the number of minutes, after setting, press K3 key again, 
“SET" and "M" stop flashing, save finished

Turn the page of the load working mode to the single real time control interface (mode 4)

1.

Press K3 key, "H" flashing, "ON" on, short press K1 or K2 key to cycle change hours: 0- - 23. 

2. Press K3 again, "H" stops flashing, "M" flashes, press K1 or K2 to change the number of minutes: 0--59. 
3. Press the K3 key again, when the load time is set, the “ON” icon is off; the “OFF” icon is on, the “M” icon stops flashing, the 
   “H” icon is  flashing, and press K1 or K2 key to modify the cycle number of hours: 0--23. 

4. Press the K3 key again, the “H” icon stops flashing, the “M” icon flashes, press K1 or K2 key to change the number of minutes in a 
   cycle: 0--59.  

5. Press the K3 key again, the SET and M icons stop flashing, the load time is set, and save the settings.

Dual-period real-time control mode

Turn the page of the load working mode to the dual-period  real time control interface (mode 5)

1. 

Press the K3 key, the “H” icon flashes, the “ON1” icon is on, press K1 or K2 key to modify the cycle number of hours: 0--23. 

2.

 

Press the K3 key again, the “H” icon stops flashing, the “M” icon flashes, press K1 or K2 key to change the number of minutes 

    in a cycle: 0--59. 
3. Press the K3 key again, when the load time 1 is set, the” ON1” icon is off, the “OFF1” icon is on, the “M” icon stops flashing, 

   the” H” icon flashes, and press K1 or K2 key to modify the cycle number of hours: 0--r23. 
4. Press the K3 key again, the” H” icon stops flashing, the “M” icon flashes, press K1 or K2 key to change the number of minutes
     in a cycle: 0--59. 
5. Press the K3 key again, the “M” icon stops flashing, the load time 1 is set up, the “H” icon flashes, the “ON2” icon is om, press 

    the K1 or K2 key to modify the cycle number of hours: 0--23. 
6. Press the K3 key again, the “H” icon stops flashing, the “M” icon flashes, press K1 or K2 key to change the number of minutes
    in a cycle: 0--59. 
7. Press the K3 key again, when the load time 2 is set, the “ON2” icon is off, the “OFF2” icon ison, the “M” icon stops flashing, the 

    “H” icon flashes, press K1 or K2 key to modify the cycle number of hours: 0--23. 
8. Press the K3  key again, the “H” icon stops flashing, the “M” icon flashes, press K1 or K2 key to change the number of minutes
     in a cycle: 0-- 59. 
9. Press the K3 key again, the “SET” and” M” icons will stop flashing, and the load time 2 will be set up. Save the settings.

2:pure light mode

Light c 

time control

4: Single period 

real time control

5: Dual-period 

real-time control

mode

 

ON

OFF

Load OFF

K4

K 4

短按

Load ON

Manually turn on and off the load

When the load mode is manual mode 1 and is not in the "alarm function" period, short press the K4 button to turn on the load, 

while in ot her modes, the K4 button is invalid

Содержание M4860ADS

Страница 1: ...ure that the battery works in the best state and greatly prolong the service life of the battery 8 It has full automatic control such as overcharge overdischarge overload protection anti reverse prote...

Страница 2: ...rtight battery where gas may accumulate the place Warning high pressure is dangerous PV arrays may generate high open circuit voltages Disconnect circuit breakers or safety before wiring and be carefu...

Страница 3: ...hort circuit in the whole process otherwise it may cause serious safety accidents Connection cable the connection cable between the controller and the battery is as short as possible which can effecti...

Страница 4: ...tal stripes rolling up dynamically Load ON Load OFF Press K1 or K2 to cycle forward or backward to browse the current working parameters or set working status Battery voltage PV1 voltage PV2 voltage C...

Страница 5: ...rface Browse and press K1 or K2 to cycle to the parameter interface you want to set Short press K3 button SET display SET font flashes to indicate that you can start to change the current parameter pr...

Страница 6: ...lashes press K1 or K2 key to change the number of minutes in a cycle 0 59 5 Press the K3 key again the SET and M icons stop flashing the load time is set and save the settings Dual period real time co...

Страница 7: ...the battery voltage here otherwise The controller will report an error and the controller will not work Battery voltage Automatic identification Set night detection voltage The night detection voltage...

Страница 8: ...or code is displayed and the buzzer alarms synchronously and the alarm continues until the error is corrected Press K4 to exit the wrong generation interface return to the main interface and turn off...

Страница 9: ...3 7V Equalization charge 14 6V no 14 8V Boost voltage 0 2V Boost charge 14 4V 14 3V 14 7V 14 15V Float charge 13 5V 13 8V 13 5V 13 14V Boost charge recovery 13 2V Low voltage recovery load output 12 5...

Отзывы: