43
Table 2 Inverter Mode Specifications
MODEL
LV 6548
Rated Output Power
6500W
Output Voltage Waveform
Pure Sine Wave
Output Voltage Regulation
120Vac± 5%
Output Frequency
60Hz or 50Hz
Peak Efficiency
91%
Overload Protection
100ms@≥205% load;5s@≥150% load; 10s@110%~150% load
Surge Capacity
2* rated power for 5 seconds
Nominal DC Input Voltage
24Vdc
48Vdc
Cold Start Voltage
23.0Vdc
46.0Vdc
Low DC Warning Voltage
@ load < 20%
23.0Vdc
46.0Vdc
@ 20% ≤ load < 50%
21.4Vdc
42.8Vdc
@ load ≥ 50%
20.2Vdc
40.4Vdc
Low DC Warning Return Voltage
@ load < 20%
24.0Vdc
48.0Vdc
@ 20% ≤ load < 50%
22.4Vdc
44.8Vdc
@ load ≥ 50%
21.2Vdc
42.4Vdc
Low DC Cut-off Voltage
@ load < 20%
22.0Vdc
44.0Vdc
@ 20% ≤ load < 50%
20.4Vdc
40.8Vdc
@ load ≥ 50%
19.2Vdc
38.4Vdc
High DC Recovery Voltage
32Vdc
64Vdc
High DC Cut-off Voltage
33Vdc
66Vdc
DC Voltage Accuracy
+/-0.3V@ no load
THDV
<5% for linear load,<10% for non-linear load @ nominal voltage
DC Offset
≦
100mV