MPM MPM-07-KPO-01 Скачать руководство пользователя страница 12

12

GB

THE MANUFACTURER WILL NOT ASSUME ANY RESPONSIBILITY IN CASE OF NON

ADHERENCE TO THESE INSTRUCTIONS.

KEEP THIS USER MANUAL CAREFULLY.

INSTALLATION

Selection of installation location

Keep the unit on a flat surface and dry place.

Leave at least 50cm space all around the unit.

Installation

Fix the exhaust pipe into the adapter, and then fix the other side of the exhaust pipe into the air outlet
vent of the unit. (anti-clockwise)
Fix the adapter into the window slider kit, then half open the window to meet the width of the window
slider kit. The length of the window slider kit is adjustable.

Incorrect mounting

The bend of the exhaust pipe is very important.

Incorrect mounting can prevent the machine from

working correctly.

Take care to prevent any sharp bows or bends of the

exhaust pipe.

The exhaust air must flow freely

WARNING

The length of the exhaust pipe is specially designed according to the specification of this

product. Do not replace or prolong it with your own private hose as this could cause

mal-function.

BE CAREFUL:

Use the shortest possible length which is 1500mm. When mounting, we

advise to keep the exhaust pipe in a horizontal position.

PART NAME

Front                                                                    

1. Air outlet vent                                                     

2. Louver                

3. Control panel                                  

4. Knob                      

5. Castor

6. Handle

                               

instrukcja_MPM-09-KPO-02.indd...12

2011-01-10...11:16:27

Содержание MPM-07-KPO-01

Страница 1: ...Przed PIerWSzYM u YcIeM zAPOzNAJ SI z INStrukcJ ObS ugI INSTRUKCJA OBS UGI KLIMATYZATOR PRZENO NY MODEL MPM 09 KPO 02 MPM 07 KPO 01 instrukcja_MPM 09 KPO 02 indd 1 2011 01 10 11 16 20...

Страница 2: ...spis tre ci INSTRUKCJA OBS UGI 3 USER MANUAL 11 PL GB instrukcja_MPM 09 KPO 02 indd 2 2011 01 10 11 16 20...

Страница 3: ...eli urz dzenie jest w czone nie pozostawiaj go bez nadzoru Wy cz urz dzenie nawet je eli b dzie pozostawione bez nadzoru tylko na chwil Nie wykorzystuj kabla zasilaj cego do przesuwania lub od czania...

Страница 4: ...Y SZE ZASADY BEZPIECZE STWA PRODUCENT NIE B DZIE ODPOWIADA ZA ADNE USZKODZENIA URZ DZENIA PRZECHOWUJ NINIEJSZ INSTRUKCJ OBS UGI NA PRZYSZ O C W BEZPIECZNYM MIEJSCU INSTALACJA Wyb r miejsca instalacji...

Страница 5: ...zosta a specjalnie zaprojektowania i odpowiada wymaganiom technicznym klimatyzatora Nie wolno jej wyd u a lub zamienia na inn rur gdy mo e to spowodowa wadliwe dzia anie urz dzenia ZACHOWAJ OSTRO NO U...

Страница 6: ...y 11 Kr ciec spustowy wody Sprawd wszystkie akcesoria do czone do urz dzenia i u ywaj ich zgodnie z instrukcj obs ugi Akcesoria Rura wylotowa Wk adka rozsuwana do okna A Wk adka rozsuwana do okna B Ad...

Страница 7: ...ANIE U ytkowanie 1 Przed w czeniem pokr t o musi by ustawione na OFF Po w czeniu urz dzenia wiate ko POWER zapali si na czerwono 2 Przekr pokr t o na porz dany tryb pracy na zielono za wieci si wska n...

Страница 8: ...pora enia pr dem wy cz i od cz urz dzenie od zasilani przed rozpocz ciem czynno ci konserwacyjnych lub naprawczych Czyszczenie Przed rozpocz ciem czyszczenia od cz jednostk od zasilania Obudow przecie...

Страница 9: ...y jednostk po up ywie trzech minut Urz dzenie Wystawione jest na bezpo rednie dzia anie promieni s onecznych Zasu zas ony Okna lub drzwi s otwarte w pokoju znajduje si du o os b lub r de ciep a Zamkni...

Страница 10: ...50Hz 1050W 1 8MPa 4 5MPa 2 0MPa 5 5MPa 50dB A 22kg 300X750X370mm 350m h 3 KLIMATYZATOR PRZENO NY PORTABLE AIR CONDITIONER MODEL WYDAJNO CH ODZENIA COOLING CAPACITY CZYNNIK CH ODNICZY REFRIGERANT NAPI...

Страница 11: ...appliance Never immerse the appliance in water or any other liquid for any reason Keep the appliance away from water or oil splashes Respect the instructions for cleaning Do not insert sharp metallic...

Страница 12: ...ace Leave at least 50cm space all around the unit Installation Fix the exhaust pipe into the adapter and then fix the other side of the exhaust pipe into the air outlet vent of the unit anti clockwise...

Страница 13: ...th of the exhaust pipe is specially designed according to the specification of this product Do not replace or prolong it with your own private hose as this could cause mal function BE CAREFUL Use the...

Страница 14: ...e Check all the accessories included in the package and please refer to the installation instructions for their usage Accessories Exhaust pipe Window slider kit A Window slider kit B Adapter 1 2 3 4 5...

Страница 15: ...machine after cooling function it is not allowed to use this function again within 3 minutes WATER DRAINAGE This product has a self evaporative system The condensing water will be recycled to cool the...

Страница 16: ...cked with dust the efficiency will reduce Open the air filter cover upwards then take out the air filter Wash the air filter by immersing it gently into warm about 40 water with a neutral detergent ri...

Страница 17: ...rce in the room Close doors and windows remove the heat source Dirty filter Clean or replace the filter s The air conditioner restart frequently Air inlet or air outlet blocked Remove the blockage The...

Страница 18: ...B A 22kg 300X750X370mm 350m h 3 KLIMATYZATOR PRZENO NY PORTABLE AIR CONDITIONER MODEL WYDAJNO CH ODZENIA COOLING CAPACITY CZYNNIK CH ODNICZY REFRIGERANT NAPI CIE ZNAMIONOWE POWER SUPPLY MOC POWER INPU...

Страница 19: ...instrukcja_MPM 09 KPO 02 indd 19 2011 01 10 11 16 30...

Страница 20: ...ja_MPM 09 KPO 02 indd 20 2011 01 10 11 16 30 yczymy zadowolenia z u ytkowania naszego wyrobu i zapraszamy do skorzystania z MPM agd S A ul Brzozowa 3 05 822 Milan wek tel 22 3805242 fax 22 3805272 www...

Отзывы: