last setting so if the Feed is turned off and then power is removed from VIN, the next time it powers up the 
Feed will be still be off. 
 
The Diagnostic Feed takes this format: 
 

+030.3:12.56:12.00:05.19:03.34:10.49:0560:YNYY:3:0558 
  A   :  B  :  C  :  D  :  E  :  F  : G  : H  :I: J 

 
A:   Ambient Temperature in Degrees C 
B:   Input Voltage at VIN 
C:   12-Volt Rail Output 
D:   5-Volt Rail Output 
E:   3.3-Volt Rail Output 
F:   Low Voltage Threshold (P2 Adjusts this in Basic Mode) 
G:   Number of Seconds for main Shutdown Timer (P1 Adjusts this in Basic Mode) 
H:   Yes/No=Good/Bad : (VIN Voltage Good, Acc Pin High, Temp Good, PS_ON Asserted) 
I:   State of Shut Down Controller: 

(0: Sleep, 1: Startup, 2: Running, 3: Count Down, 4: Shut Down, 6:Bad Temperature, 7:Fault) 

J:   Relative Count Value for Shutdown Counter (seconds) 
 

4.5. 

Extended Basic Programming Examples 

In the below example, we program the DSATX. Tell it to use the Pots (P1,P2) for the Timer1 (Main 

Countdown Timer) and the low voltage threshold cutout (P2 selects a value between 10 and 12 volts). 
Maxtimer1 is the maximum seconds you can set with the P1 Pot. Basically, if you set the pot half way and had 
Maxtimer1 set to 1200, it would shutdown in 600 seconds. If you set the Maxtimer1 to 0060 you would have 
between 0 and 60 seconds to select with the P1 Pot. You must type 4 numbers, Ex: 0123 
 

>E 

 

 

 Type the letter E 

Enable Writing? y/n 

>y 

 

 

 Type the letter y  

>P 

 

 

 Type the letter P 

PROGRAM MODE 
Use POTs? y/n 

>y 

 

 

 Type the letter y  

MAXTIMER1: 

>1200            

 Type ‘1200’ (must type 4 numbers)         

VTURNON? y/n 

>n 

 

 

 Type the letter n 

DONE 

 

In the below example, we program the DSATX to hard code the values for the Timer1 (Main Countdown 

Timer) and the low voltage threshold. This will override P1 and P2 Pots. If you set LOWVOLTS to 1050, the 
unit wouldn’t shutdown until it hit 10.50 volts on the VIN input. If you set Timer1 to 0600, then after 600 
seconds of ACC going away, the computer will begin the shutdown sequence. We will also enable the 
VTURNON feature so the computer will turn on only after the engine is running. 

 

>E 

 

 

 Type the letter E 

Enable Writing? y/n 

>y 

 

 

 Type the letter y  

>P 

 

 

 Type the letter P 

PROGRAM MODE 
Use POTs? y/n 

>n 

 

 

 Type the letter n  

LOWVOLTS: 

>1050            

 Type ‘1050’ (must type 4 numbers)   

TIMER1: 

>0600            

 Type ‘0600’ (must type 4 numbers)               

VTURNON? y/n 

>y 

 

 

 Type the letter y 

DONE 

 

Содержание DuraWatt DSATX

Страница 1: ...Connectivity 8 4 1 Serial Port Adapters 8 4 2 Serial Port Overview 8 4 3 Basic Programming Control 8 4 4 Diagnostic Feed 8 4 5 Extended Basic Programming Examples 9 4 6 Advanced Features 10 4 7 Advan...

Страница 2: ...tion J5 J2 J8 DC DC Power Supply 5VSB 5V 3 3V 12V PSON 12V Adjust POTs JP1 ATX 20p 12V FAN Chassis Ground GND 12 Volts In VIN Accessory In ACC Status LED MotherBoard Switch Advanced Options Communicat...

Страница 3: ...B Power Switch Computer Motherboard Hard Drive CD ROM etc 2 4 Precautions and Warnings Operating a personal computer in a motor vehicle can be dangerous Improper use or negligence can result in damage...

Страница 4: ...ort Enables Advanced Modes field upgrades and diagnostics Note Do Not Over Turn P1 and P2 only 270 degrees is available 2 6 Bench Testing The DSATX can be tested in the lab before being installed into...

Страница 5: ...to have the ability to go to the gas station and have the computer still running while you pump and pay so when you come back you don t have to wait a boot up When you get home you don t want a dead b...

Страница 6: ...te computer is on 1 blinks Main Countdown Timer 2 blinks Power Down after shutdown pulse is sent 3 blinks N A 4 blinks Over or Under Temperature Condition Are you using a fan 5 blinks Power Supply Ove...

Страница 7: ...fail for any reason When rails are shorted for example 5 volts to 12 volts other power supplies on the market will not detect an over voltage condition which will damage 5 volt rated computer componen...

Страница 8: ...e HyperTerminal or TeraTerm are examples of applications that can be used to interface with the DSATX s Extended Basic and Advanced Modes The USB adapter creates a virtual COMM Port 4 3 Basic Programm...

Страница 9: ...er1 is the maximum seconds you can set with the P1 Pot Basically if you set the pot half way and had Maxtimer1 set to 1200 it would shutdown in 600 seconds If you set the Maxtimer1 to 0060 you would h...

Страница 10: ...ENABLESLEEP 13 1 1 yes 0 no If set Unit Will go use Sleep Mode ACC High for Wake Up FEEDON 14 1 1 yes 0 no If set Serial Port Diagnostic Status Feed is Enabled VTURNON 15 0 1 yes 0 no If set Mb Switc...

Страница 11: ...Input Threshold Low 4V High 7V 30V Max ACC Input Impedance 100k Ohms MB Power Switch Output Drive Open Collector 50mA Max AUX Output Drive Open Collector 50mA Max User Switch Pull Up Drive 10k Ohms t...

Страница 12: ...5V GND 3 3V 3 3V 5V 5V N A GND GND GND GND 12V PSON J8 ATX12V J7 ATX PWR ACC VIN GND J5 INPUT PWR 12 N C GND GND TX OUT 5VD RX IN J1 FAN J2 COMM RESET GND GND GND GND GND GND G MB_SW F AUX_SW E SL_SEN...

Страница 13: ...nnected to the Mpegbox com product or other consumable parts transportation costs or any damage incurred in transit This warranty will become void if the serial number identification has be wholly or...

Отзывы: