27
8.4.
Alarms
All V-2 Series high pressure systems use one alarm output, NC (Normally Closed) or NO
(Normally Open) to interface with machine tool. If a fault occurs, a signal is sent to the alarm circuit on
machine tool, which will put machine tool in to feed hold.
MP Systems recommends using Normally Closed alarm circuits. This will allow machine tool to
go into alarm if the V-2 Series ever becomes disconnected from machine tool.
8.4.1.
Alarm Descriptions
Alarm Display
Symptom(s)
Cause
Red Light
1. Clogged Filter(s)
2. Prime Issue
3. Machine Coolant Tank
Screen Clogged
4. Clogged Hose(s)
5. Sucking in Air
6. Improper Feed Pump
Rotation.
Pressure is below 2psi
on filter outlet when
running.