SpeCiFiCatiOnS

Capacity

 

Racks per hr. 

21

Motor Horsepower

 

Wash 

1

Water Consumption

 

 Imp. gal/liters  

 

per hr. (max. use) 

31.9/145

 

Imp. gal/liters  

 

 

per rack   

1.5/6.8

Temperatures °F/°C

 

 Wash (minimum) 

150/66

 

Rinse (minimum) 

180/82

Heating

 

 Tank heat, electric (kW) 

2

 

Electric booster

 

 (kW required for 40°F/22°C rise)  

6

 

(kW required for 70°F/39°C rise) 

9

Time Cycle in Seconds

 

 Wash 

90

 

 Rinse 

26

 

 Drain/fill 

25

 

Total cycle 

141

501Ht

Undercounter 

High Temperature Dishwashing Machine

with Built-in Booster Heater

115V

115V

L1

L2

N

G

Single Phase

Three Phase

G

L3

L2

L1

115V

N

240V

208V

208V

240V

208V

240V

   

Uncrated 

Crated 

 

Height*

 

33-3/4" [860] 

39-1/2" [1003]

 

Width

 

24" [610] 

25" [635]

 

Depth

 

24" [610] 

25-1/2" [647]

 

Ship Wt. lbs/kg

 

178/79 

198/90

  * Front leveling feet provided.

24" [610]

33-3/4" [857]

15-3/4" 

[400]

Clearance

40-1/2" [1029]

2" [51]

15-3/4" [400]

25" [635]

4" [102]

plan View

24" [610]

33-3/4" [857]

15-3/4" 

[400]

Clearance

40-1/2" [1029]

2" [51]

15-3/4" [400]

25" [635]

4" [102]

Front View

24" [610]

33-3/4" [857]

15-3/4" 

[400]

Clearance

40-1/2" [1029]

2" [51]

15-3/4" [400]

25" [635]

4" [102]

Side View

utilities

  1  Electrical Connection

115/208-240/60/1; 3 wire plus ground. Hard wiring required (see box) 

115/208-240/60/3; 4 wire plus ground.

  2  Water Connection

140°F/60°C Min., hot water for 40°F/22°C rise booster. 

110°F/43°C Min., hot water for 70°F/39°C rise booster. 

5 ft. long 1/2" I.D. flexible fill hose with 3/4" garden hose connection provided. 

Flow pressure: 25-95 psi (173-656 kPa) 

  3  Drain Connection

5 ft. long, 5/8" I.D. flexible drain hose provided. For Y connection into 1-1/2" drain.  

Max. drain flow: 7 gpm.; 32 imp, maximum 3' height above floor

 

 

 

Minimum 

Maximum

 

1 Phase 

 

Supply Ckt.  Overcurrent 

 

40°F/22°C 

Rated  Conductor  Protective 

  Rise Booster  Amps  Ampacity 

Device

  115/208/60/1  32 

40 

40

  115/240/60/1  36 

40 

40

 

 

 

Minimum 

Maximum 

 

 

 

Supply Ckt.  Overcurrent 

 

70°F/39°C 

Rated  Conductor  Protective 

  Rise Booster  Amps  Ampacity 

Device

  115/208/60/1  45 

60 

60

  115/240/60/1  50 

60 

60

 

  

 

Minimum 

Maximum

 

  

 

Supply Ckt.  Overcurrent 

 

 40°F/22°C 

Rated  Conductor  Protective 

  Rise Booster  Amps  Ampacity 

Device

  115/208/60/3  22 

30 

30

  115/240/60/3  24 

30 

30 

 

  

 

Minimum 

Maximum

 

3 Phase 

 

Supply Ckt.  Overcurrent 

 

70°F/39°C 

Rated  Conductor  Protective 

  Rise Booster  Amps  Ampacity 

Device

  115/208/60/3  29 

35 

35

  115/240/60/3  33 

40 

40

501HTN without booster 

750 Watt tank heat

Electric Specs

Rated Amps

115/60/1

12

Отзывы: