VPort 25 User’s Manual
First Time Installaton and Configuration
2-7
NOTE
Be sure to arrange the cables carefully to make sure that all cables are connected properly. We
recommend connecting the Ethernet cable first, and then the 9-pin terminal block. Connect the
2-pin terminal block last.
NOTE
The conduit hole must face downward to provide the VPort 25 with IP66 protection against rain
when installed in an outdoor environment.
Step 5: Mount the bottom case on the ceiling or accessory’s mounting kit (VP-MK)
a) Mounting on the ceiling
Step 1: Attach the bottom case to the appropriate mounting location on the wall, and mark the
positions of the four screw holes with a pen or a pencil.
Step 2: In the marked locations, drill a hole slightly smaller than the supplied screw anchors.
Step 3: Put anchors into these drilled holes.