- 6 -
Hardware Installation
Step 1:
Open and remove the top cover.
Use the Hex security screwdriver (with a pin) to loosen the top cover
screws and remove the dry pack that is in the top cover.
Step 2:
Use the markings on the installation sticker to position the drill bit
before drilling holes. There are 3 types of installation.
Mounting with 4 mounting screws
To mount the camera on the train,
drill a hole through the gray portion
of the sticker and then mount the
camera with 4 screws.
NOTE
The recommended torque of the top cover is 12 kg-cm and 25
kg-cm for mounting the camera on the train.
Step 3:
Connect the camera with the 4-pin M12 D-code Ethernet
connector and 5-pin M12 connector with 24 VDC power to activate the
defrost heater and digital output.
NOTE
Connectors used with the cameras should have a minimum IP
rating of IP67. The paint and the screws located on the top cover
have to pass the ASTM B368 standard (CASS) with testing lasting
125 hours; but this standard doesn’t include the cable connector
and cable gland.