background image

 

3.

 

Hardware Connection Description 

This chapter describes how to connect the UC-8112 to a network and various devices for first time testing 
purposes. 

The following topics are covered in this chapter: 

  Wiring Requirements 

 Connecting the Power 

 Grounding the Unit 

  Connecting to the Console Port 

  Connecting to the Network 

  Connecting to a Serial Device 

  Inserting the SD and SIM Card 

  USB Port 

  Inserting a Micro SD Card 

  Installing the Cellular Module 

  Installing the Wi-Fi Module 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание UC-8112-LX-STK

Страница 1: ...UC 8112 LX STK User s Manual First Edition April 2015 www moxa com product 2015 Moxa Inc All rights reserved Reproduction without permission is prohibited...

Страница 2: ...erves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be acc...

Страница 3: ...dule 3 5 Installing the Wi Fi Module 3 7 4 Remote Configuration and Management 4 1 Connecting to the UC 8112 via Webmin 4 2 Configuring Webmin 4 2 Change Language and Theme 4 3 Webmin Action Logs 4 3...

Страница 4: ...the Wi Fi Module 5 2 Bridging the Cellular to Serial Interface 5 4 UDP Server to Serial Device 5 4 UDP Client to Serial Device 5 4 TCP Server to Serial Device 5 4 TCP Client to Serial Device 5 4 Confi...

Страница 5: ...UC 8100 computer optional cellular and Wi Fi modules and various software packages this compact Starter Kit helps users establish their system architecture in no time The following topics are covered...

Страница 6: ...11b g n UC 8112 Starter Kit Package Checklist Before installing the UC 8112 verify that the package contains the following options UC 8112 LX Computer Kit UC 8112 LX computer x 1 Console cable x 1 GPS...

Страница 7: ...e Even Odd Space Mark Flow Control XON XOFF ADDC automatic data direction control for RS 485 Baudrate Max 921600 bps Serial Signals RS 232 TxD RxD RTS CTS GND RS 422 TxD TxD RxD RxD GND RS 485 4w TxD...

Страница 8: ...225 mA 24 VDC Standards and Certifications Safety UL 60950 1 EN 60950 1 CCC GB9254 GB17625 1 EMC EN55022 Class B EN 55024 4 2 EN 55024 4 3 EN 55024 4 4 FCC Part 15 Subpart B Class A Green Product RoHS...

Страница 9: ...y of devices The UC 8112 comes with a reliable and stable hardware platform that lets you devote the bulk of your time to application development In this chapter we provide basic information about the...

Страница 10: ...UC 8112 LX STK Manual Hardware Introduction 2 2 Appearance Front View Top Bottom Views Top Bottom...

Страница 11: ...en Power is on and the computer is working normally Off Power is off LAN1 2 On RJ45 connector Green Steady On 100 Mbps Ethernet link Blinking Data transmitting Yellow Steady On 10 Mbps Ethernet link B...

Страница 12: ...mode is enabled the green Diagnosis LED will keep blinking Any successful pairing will disable the automatic pairing mode immediately Off Blinking Off Automatic Pairing QR Code Scanning the QR Code o...

Страница 13: ...ou need to change the battery contact the Moxa RMA service team WARNING There is a risk of explosion if the battery is replaced by an incorrect type Placement Options There are two sliders on the back...

Страница 14: ...unting brackets on the side panel of the computer and fasten with screws Install the computer on a wall or cabinet by fastening two screws for each bracket NOTE Before tightening the screws into the w...

Страница 15: ...esting purposes The following topics are covered in this chapter Wiring Requirements Connecting the Power Grounding the Unit Connecting to the Console Port Connecting to the Network Connecting to a Se...

Страница 16: ...system ATTENTION Safety First Be sure to disconnect the power cord before doing installations and or wiring Electrical Current Caution Calculate the maximum possible current in each power wire and co...

Страница 17: ...e with nearby radio and television reception It is essential that only the supplied power cord be used You are cautioned that changes or modifications not expressly approved by the party responsible f...

Страница 18: ...configured by software for RS 232 RS 422 or 2 wire RS 485 The precise pin assignments are shown in the following table Terminal Block RS 232 422 485 Pinouts Pin RS 232 RS 422 RS 485 1 TXD TXD 2 RXD TX...

Страница 19: ...llow these steps 1 Remove the screws on the side panel and take off the cover 2 Insert the micro SD card into the socket Make sure you insert the card in the correct direction 3 Replace the cover to c...

Страница 20: ...enna connectors on the cellular module Connect the cable to either connector 4 Plug the other end of the cable into the connector on the front panel of the UC 8112 Remove the black plastic cover first...

Страница 21: ...lular module into the socket and then tighten the screws to fasten the socket 3 Use the two silver screws to fasten the stabilization bracket to the Wi Fi module Make sure you connect the bracket in t...

Страница 22: ...n 3 8 4 Install the other end of the cable onto the connector on the front panel of the UC 8112 Remove the black plastic cover first 5 Install the connector place the locking washer first and then tig...

Страница 23: ...apter Connecting to the UC 8112 via Webmin Configuring Webmin Change Language and Theme Webmin Action Logs Webmin Configuration Webmin Users Configuring System Bootup and Shutdown Disk and Network Fil...

Страница 24: ...ng information for Username and Password Username root Password root The main menu options will be displayed on the left and the main information of the UC 8100 will be shown in the middle Check all o...

Страница 25: ...Action Logs When the file log function has been enabled you may find the action log here If you wish to search the logs in all modules select In any module if you wish to search the logs in the speci...

Страница 26: ...computer IP Access Control This option helps you configure the IP address control for the UC 8100 computer You may allow or deny the specific IP addresses You may also decide whether or not to resolv...

Страница 27: ...Other functions are also provided Users may configure all settings on this page When finished Click Save For other configurations click Return to Webmin configuration Proxy Servers and Downloads This...

Страница 28: ...ackground color text color and link color etc When finished click Save For other configurations click Return to Webmin configuration Webmin Modules This option allows users to install modules on the U...

Страница 29: ...y you may update or upgrade the operating system and environment from this option When finished click Save For other configurations click Return to Webmin configuration Language This option allows use...

Страница 30: ...bmin Select the options from the following figure When finished click Save For other configurations click Return to Webmin configuration Upgrade Webmin This option allows users to upgrade the Webmin v...

Страница 31: ...ure all settings in this figure When finished click Save For other configurations click Return to Webmin configuration Two Factor Authentication This option allows users to enable the addition device...

Страница 32: ...these modules to different categories When finished click Change Categories For other configurations click Return to Webmin configuration Edit Categories This option allows users to edit the name of t...

Страница 33: ...field When finished click Save For other configurations click Return to Webmin configuration Webmin Themes This option allows users to select the Webmin themes from the drop down list When finished cl...

Страница 34: ...ck Save For other configurations click Return to Webmin configuration File Locking This option allows users to lock specific files to prevent concurrent modification which could lead to file corruptio...

Страница 35: ...ground Status Collection This option allows users to decide if they want to collect the status in the system background When finished click Save For other configurations click Return to Webmin configu...

Страница 36: ...tions click Return to Webmin configuration Web Server Options This option allows users to configure the web server settings When finished click Save For other configurations click Return to Webmin con...

Страница 37: ...and the text for email content When finished click Save If you want to send the email immediately click Send Email For other configurations click Return to Webmin configuration SSL Encryption This op...

Страница 38: ...e the certificate authority All detailed descriptions are displayed on this page When finished click Save For other configurations click Return to Webmin configuration Webmin Users This option allows...

Страница 39: ...ng Unix User Authentication This option allows users to manage user authentication Users may decide or deny access for specific Unix users When finished click Save For other configurations click Retur...

Страница 40: ...factor authentication you may check the status of the two factor authentication on this page Setup RBAC This option allows users to set up RBAC Password Restrictions This option allows users to config...

Страница 41: ...ase This option allows users to configure the user and group database settings When finished click Save For other configurations click Return to Webmin configuration Configuring System When you click...

Страница 42: ...ows users to enable specific actions when the system boots up or shuts down Click a button to perform the associated function Disk and Network Filesystems This option allows users to mount the system...

Страница 43: ...otup This option allows users to create or delete the initial process file when the computer is booting up If you want to delete something select the ID and click Delete Selected Processes at the bott...

Страница 44: ...guration and Management 4 22 Running Processes This option allows users to view the current running processes Click Search to search for a the specific process You can also terminate or kill a process...

Страница 45: ...led cron jobs or create a new scheduled cron job To create a new cron job click the Create a new scheduled cron job button and enter the information in the fields as required When finished click Creat...

Страница 46: ...n finished click Save Software Package Updates This option allows users to update the software package on the UC 8100 computer Select the package and then click Update Selected Packages You may also c...

Страница 47: ...ages This option allows users to search for installed packages or install a new package You may also upgrade all packages on this page System Documentation This option allows users to search the syste...

Страница 48: ...and edit the current system log or create a new system log Click the system log you want to edit and then provide the relevant information Click Save You may also delete this log by clicking Delete C...

Страница 49: ...the appropriate option to continue the configuration you would like to take care of Apache Webserver This option allows users to view or delete the current Apache Webservers You may also create a vir...

Страница 50: ...users to configure the DHCP server settings Various functions are also provided including Edit Client Options Edit TSIG keys Manually Edit Configuration List Active Leases To edit the subnet settings...

Страница 51: ...nfiguration When finished click Save Configuring Others Click Others Two options will be displayed Click the appropriate option to take further action Command Shell This option allows users to manuall...

Страница 52: ...ke further action Bandwidth Monitoring This option allows users to configure the network interface and the bandwidth condition Select the network interface and then click Setup Now for additional conf...

Страница 53: ...te view or apply the current network interfaces Select the functions you wish to use Routing and Gateways This option allows users to configure the routing and gateways configurations When finished cl...

Страница 54: ...Hardware Click Hardware Two options will be displayed Click the appropriate option to take further action Partitions and Local Disks This option allows users to edit the disk partitions You may edit...

Страница 55: ...ion allows users to configure system time and hardware time When finished click Apply or Save Viewing More Options Four more options can be found in the left lower corner of the Webmin window Click an...

Страница 56: ...t the file and then click Export as CSV System Information This item allows users to view the current system information Refresh Modules This item allows users to refresh the current modules on the UC...

Страница 57: ...ter The following topics are covered in this chapter Enabling Cellular Module Configuring the Cellular Module Configuring the Wi Fi Module Bridging the Cellular to Serial Interface UDP Server to Seria...

Страница 58: ...ular module type the following command cell_mgmt power_on To keep the UC 8112 computer constantly connecting to the network type the following command keep_alive To enable the routing function of the...

Страница 59: ...KEY Configuring WPA WPA2 SSID Password PSK To configure the SSID and password for WPA WPA2 edit the following content WPA WPA2 PSK network ssid WES_AP proto WPA WPA2 RSN key_mgmt WPA PSK pairwise TKIP...

Страница 60: ...Shell so that the signal between the DUP client and serial device can be transmitted socat UDP SENDTO REMOTE IP REMOTE PORT file dev ttyM0 nonblock raw echo 0 waitlock var run ttyM0 b115200 TCP Serve...

Страница 61: ...psk txt path certificate etc racoon certs remote anonymous exchange_mode main aggressive proposal encryption_algorithm aes_256 hash_algorithm sha256 authentication_method pre_shared_key dh_group modp1...

Страница 62: ...the IPSec function when the system starts up 1 2 Locate the Bootup and Shutdown option in Webmin 3 Click Create a new bootup and shutdown action 4 Enter the following commands in the Bootup commands f...

Страница 63: ...6 6 Data Acquisition This chapter describes how to use the UC 8112 computer to acquire data from an ioLogik E1242 RTU controller The following topics are covered in this chapter Acquiring Data...

Страница 64: ...1242 RTU controller To acquire data from the controller use the following commands in the Command Shell field To read the value from Digital Input 0 Em2240 d 192 168 31 66 i 0 To read the value from A...

Страница 65: ...o provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not...

Отзывы: