Moxa Technologies TN-5916 Series Скачать руководство пользователя страница 10

- 10 - 

Connecting the Relay Outputs 

Each TN-5916 router has two sets of relay outputs—relay output 1 and 
relay output 2.The M12 A-coded 5-pin male connector on the TN-5916 
front panel is used for the two relay outputs. Use a power cord with an 
M12 A-coded 5-pin female connector to connect the relay contacts. You 
can purchase an M12 power cable from Moxa; the model number is 
CBL-M12 (FF5P)/OPEN-100 IP67. 

Pinouts for the TN-5916’s Relay Output Port 

 

N.C.: Not connected 
FAULT: 
The two sets of relay contacts of the M12 A-coded 5-pin male connector 
are used to detect user-configured events. The two wires attached to the 
fault contacts form an open circuit when a user-configured event is 
triggered. If a user-configured event does not occur, the fault circuit 
remains closed. 

Connecting the Data Lines 

10/100BaseT(X) Ethernet Port Connection 

All TN-5916 models have 16 10/100BaseT(X) Ethernet ports (4-pin 
shielded M12 connector with D coding). The 10/100TX ports located on 
the TN-5916 front panel are used to connect to Ethernet-enabled devices. 
Most users configure these ports for Auto MDI/MDI-X mode, in which case 
the port’s pinouts are adjusted automatically depending on the type of 
Ethernet cable used (straight-through or cross-over), and the type of 
device (NIC-type or HUB/Switch/Router-type) connected to the port.   
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X 
(HUB/Switch/Router-type) ports. We also give cable wiring diagrams for 
straight-through and cross-over Ethernet cables. 

10/100BaseT(X) Port Pinouts 

 

Housing: shield 
 
 
 

Содержание TN-5916 Series

Страница 1: ...upport Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70...

Страница 2: ...ughNet TN 5916 NAT router is shipped with the following items If any of these items is missing or damaged please contact your customer service representative for assistance 1 Moxa ToughNet NAT router...

Страница 3: ...th IP67 rated male 4 pin M12 D coded connector CBL M12 FF5P OPEN 100 IP67 1 meter M12 to 5 pin power cable with IP67 rated female 5 pin M12 A coded connector M12D 4P IP68 Field installable M12 D coded...

Страница 4: ...9 PWR2 LED for power input 2 10 FAULT LED 11 MSTR HEAD LED for ring master or chain head 12 CPLR TAIL LED for ring coupler or chain tail 13 TP port s 10 100 Mbps LED 14 10 100BaseT X port female 4 pi...

Страница 5: ...15 Removing the seal will invalidate the warranty Ports including 3 5 and 14 that are not in use must be tightly covered with protective caps an optional accessory to ensure IP54 IP67 rated protection...

Страница 6: ...are suitable by inserting the screw through one of the keyhole shaped apertures of the ToughNet router STEP 3 Once the screws are fixed in the wall hang the ToughNet router on the 4 screws through th...

Страница 7: ...To remove the Moxa ToughNet Router from the DIN rail use a screwdriver to pull out the two spring loaded brackets from the bottom until they are fixed in a locked position Then reverse Steps 3 and 4 a...

Страница 8: ...sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring through the same wire conduit To avoid interference wires with different si...

Страница 9: ...ower source 2 PWR1 Neutral DC Connect PWR1 Neutral DC to the negative terminal when using a DC power source 3 Chassis Ground Connect the Chassis Ground to the safety ground terminal for DC inputs 4 PW...

Страница 10: ...red event is triggered If a user configured event does not occur the fault circuit remains closed Connecting the Data Lines 10 100BaseT X Ethernet Port Connection All TN 5916 models have 16 10 100Base...

Страница 11: ...pin M to M12 4 pin M Cross Over Cable Wiring M12 4 pin M to M12 4 pin M Straight Through Cable Wiring M12 4 pin M to RJ45 8 pin Cross Over Cable Wiring M12 4 pin M to RJ45 8 pin Straight Through Cabl...

Страница 12: ...The bypass relay function helps the network recover from single node failures in a linear topology Router A Router B Router C Router D Since the maximum segment length of category 5 twisted pair cable...

Страница 13: ...er the Master of this Turbo Ring or the Head of this Turbo Chain Blinking When the TN router is Ring Master of this Turbo Ring and the Turbo Ring is broken or it is Chain Head of this Turbo Chain and...

Страница 14: ...4 IGMP Groups 256 Interface Fast Ethernet Front cabling M12 connector 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection Console Port M12 A coding 5 pin male connector...

Страница 15: ...4 5 Surge Power 2 kV Signal 2 kV IEC 61000 4 6 CS 10 V IEC 61000 4 8 Rail Traffic EN 50155 EN 50121 4 EN 45545 2 This product is suitable for rolling stock railway applications as defined by the EN 50...

Отзывы: