Wiring Requirements 

 

WARNING 

Turn the power off before disconnecting modules or wires. The 
correct power supply voltage is listed on the product label. Check 
the voltage of your power source to make sure you are using the 
correct voltage. Do NOT use a voltage greater than what is 
specified on the product label. 
These devices must be supplied by a SELV source as defined in 
the Low Voltage Directive 2006/95/EC and 2004/108/EC. 

 

 

 

ATTENTION 

Safety First! 
Be sure to disconnect the power cord before installing and/or 
wiring your Moxa switch. 
This device has UL508 approval. Use copper conductors only, 
60/75°C, and tighten to 4.5 pound-inches. For use in pollution 
degree 2 environments. 

 

 

 

ATTENTION 

Safety First! 
Calculate the maximum possible current in each power wire and 
common wire. Observe all electrical codes dictating the 
maximum current allowable for each wire size. If the current goes 
above the maximum ratings, the wiring could overheat, causing 
serious damage to your equipment. 

 

 

Please read and follow these guidelines: 

 

Use separate paths to route wiring for power and devices. If power 
wiring and device wiring paths must cross, make sure the wires are 
perpendicular at the intersection point. 

 

NOTE: Do not run signal or communications wiring and power wiring 
through the same wire conduit. To avoid interference, wires with 
different signal characteristics should be routed separately. 

 

You can use the type of signal transmitted through a wire to 
determine which wires should be kept separate. The rule of thumb is 
that wiring that shares similar electrical characteristics can be 
bundled together. 

 

Keep input wiring and output wiring separated. 

 

It is strongly advised that you label wiring for all devices in the system 
when necessary. 

Grounding the TN-5308 

Grounding and wire routing help limit the effects of noise due to 
electromagnetic interference (EMI). Run the ground connection from the 
grounding screw to the grounding surface prior to connecting devices. 

Содержание TN-5308

Страница 1: ... 2012 Moxa Inc All rights reserved P N 1802053080012 TN 5308 Hardware Installation Guide Moxa ToughNet Switch Third Edition February 2012 ...

Страница 2: ...ions Package Checklist Your TN 5308 is shipped with the following items If any of these items is missing or damaged please contact your customer service representative for assistance Moxa ToughNet Switch Panel Mounting Kit Hardware Installation Guide Moxa Product Warranty Statement Features High Performance Network Switching Technology 8 10 100BaseT X ports Store and Forward switching process type...

Страница 3: ...ng 3 Port label 4 Screw holes for panel mounting kit or DIN rail mounting kit there are 3 holes top middle bottom left and bottom right 5 Power input LED 6 Power input port male 6 pin shielded M12 connector with A coding 7 Grounding screw 8 Power input port pin assignment 9 Model name 10 TP port pin assignment 11 Model label ...

Страница 4: ... coding 3 Port label 4 Screw holes for panel mounting kit or DIN rail mounting kit there are 3 holes top middle bottom left and bottom right 5 Power input LED 6 Power input port male 6 pin shielded M23 connector with A coding 7 Grounding screw 8 Power input port pin assignment 9 Model name 10 TP port pin assignment 11 Model label ...

Страница 5: ... 5 Mounting Dimensions unit mm TN 5308 LV TN 5308 MV ...

Страница 6: ...engths of TN 5308 LV and TN 5308 MV are different TN 5308 LV uses M3 30 mm screws TN 5308 MV uses M3 40 mm screws Please use the screws packed in the panel mounting kit DIN Rail Mounting optional With the optional DIN Rail mounting kit DK TN 5308 must be purchased separately you can mount the TN 5308 LV MV on a 35mm DIN Rail STEP 1 Fix the DIN Rail attachment plate onto the rear panel of the switc...

Страница 7: ...ent goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Please read and follow these guidelines Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring through the same wire...

Страница 8: ...M23 A coded 5 pin female connector to connect the switch to the DC power input Pinouts for the power input port on the TN 5308 LV Pinouts for the power input port on the TN 5308 MV STEP 1 Plug your power cord connector to the power input port of the TN 5308 switch STEP 2 Screw the nut on your power cord connector to the power input connector on the switch to ensure a tight connection ATTENTION Bef...

Страница 9: ...matically depending on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port In what follows we give pinouts for both MDI NIC type ports and MDI X HUB Switch type ports We also give cable wiring diagrams for straight through and cross over Ethernet cables Pinouts for the 10 100BaseT X Ports on the TN 5308 Pinouts for...

Страница 10: ... Wiring Auto MDI MDI X Connection The Auto MDI MDI X function allows users to connect TN 5308 s 10 100BaseTX ports to any kind of Ethernet device without needing to pay attention to the type of Ethernet cable being used for the connection This means that you can use either a straight through cable or cross over cable to connect the TN 5308 to Ethernet devices ...

Страница 11: ...of the switched ports a decision is made to filter or forward the packet Packets with source and destination addresses belonging to the same port segment will be filtered constraining those packets to one port and relieving the rest of the network from the need to process them A packet with destination address on another port segment will be forwarded to the appropriate port and will not be sent t...

Страница 12: ...ode as required by the IEEE 802 3u standard Specifications Technology Standards IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X IEEE 802 3x for Flow Control Processing Type Store and Forward Flow Control IEEE802 3x flow control back pressure flow control Interface M12 Ports 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection LED Indicators PWR 10 100M Power Require...

Страница 13: ...EN61000 4 3 RS level 4 EN61000 4 4 EFT level 3 EN61000 4 5 Surge level 3 EN61000 4 6 CS level 3 EN61000 4 8 EN61000 4 11 EN61000 4 12 Shock IEC61373 Freefall IEC60068 2 32 Vibration IEC61373 Note Please check Moxa s website for the most up to date certification status WARRANTY 5 years Details See www moxa com warranty Technical Support Contact Information www moxa com support Moxa Americas Toll fr...

Отзывы: