- 4 -
Powering the TC-6110
TC-6110 computers come with DC power inputs. When connecting the
TC-6110 to an office AC source (for testing), an adaptor must be used. To
connect the AC adaptor, follow these steps:
Step 1:
Connect the ends of the extended power switch cable to the male
portion of the 2-pin Euroblock (provided in the package).
Step 2:
Plug the male Euroblock into the matching female terminal on the
front panel.
Step 3:
Make sure the power switch is turned off (the
Open
position as
indicated in the diagram
below).
Step 4:
Connect the earth/ground cable to the
Phillips-head ground connector on the lower right
corner of the front panel.
Step 5:
Connect the power cable (CBL-Power Jack to M12) to the M12
(A-coded, 5-pin, male) connector as shown at right. Then connect the
power connector to power input 1 on the front panel.
Step 6:
On the other side of the power cable, connect to the
PWR-24250-DT-S1 power adaptor (optional), and a PWC-series power
cord (optional).
Step 7:
To check power redundancy, use the same method to connect
the power to the power input 2.
Step 8:
Switch on the TC-6110 (
Short
state). If power supply is
connected properly, both power input and system power LEDs will be on
(green), as well as the yellow
Ready
LED.