2-4
Smartio
C104H/HS User’s Manual
run the software utility,
Io-irq.exe
, in the driver diskette under
DOS
system to
change the hardware configuration.
1.
Choose a PC that has
DOS
system inside.
2.
Power off the PC.
3.
Make sure no hardware conflict and plug the board in a free 16-bit slot of the PC,
one board at a time with JP1 open
.
+
If you are installing multiple boards, insert one board at a time and
configure it using the Io-irq program before inserting the next board.
This is to prevent conflict between two boards with same default
hardware settings.
The
Smartio
C104 Series has the following default (factory) settings,
I/O address:
0x180
(Port 1),
0x188
(Port 2),
0x190
(Port 3),
0x198
(Port 4)
IRQ:
10
INT Vector:
0x1C0
Configuration Access Port (CAP):
0x180
4.
Power on the PC and enter into
DOS
system.
5.
Run the utility “
Io-irq.exe
” contained in the driver diskette to set up I/O address,
IRQ and INT vector of the board. Please refer to the next section, “IO-IRQ Utility
and Hardware Configuration” for more details. Or follow the on-line help to
configure the
Smartio
C104 Series board.
After completing the hardware configuration, the board is ready for use under
operating systems, such as Windows NT and 95/98, DOS, Windows 3.x, etc.
IO-IRQ Utility and Hardware Configuration
Note that the CAP address, e.g. 0x180, is identical to
the first port's I/O address
except in one case that the JP1 jumper is installed before powering on the PC. In this
case, the CAP address will be forced to
0xA700
. The CAP address must be typed
correctly. With the correct CAP address, the utility can find the configuration stored
in the
on-board EEPROM
and display it on the configuration panel. The CAP
address is the only channel via which the configuration utility Io-irq.exe can access
the board.