- 18 -
Physical Characteristics
Housing
Metal
Dimension (W x H x D) 36 x 135 x 111 mm (1.42 x 5.32 x 4.37 in)
Weight
590 g (1.30 lb)
Installation
DIN rail mounting
Environmental Limits
Operating Temperature
Standard Models:
Wide Temp. Models:
-10 to 60°C (14 to 140°F)
-40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5% to 95% (non-condensing)
Altitude
Up to 2000 m
Note: Please contact Moxa if you require
products guaranteed to function properly at
higher altitudes.
Standards and Certifications
Safety
UL 61010-2-201, EN 62368-1
EMC
EN 61000-6-2/6-4
EMI
CISPR 22, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1
kV
IEC 61000-4-6 CS: Signal: 10 V
IEC 61000-4-8 PFMF: 30A/m, 60 s
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
Note: Please check Moxa’s website for the latest certification status.
MTBF (mean time between failures)
Time
1,109,179 hours
Standard
Telcordia (Bellcore), GB
Warranty
Warranty Period
5 years
Details
See www.moxa.com/warranty
ATTENTION
This device complies with Part 15 of the FCC rules.
Operation is subject to the following conditions:
1.
This device may not cause harmful interference.
2.
This device must accept any interference received including
interference that may cause undesired operation.