Wiring the Redundant Power Inputs 

Each PT switch has two sets of power inputs: power input 1 and power 
input 2. 

 

STEP 1

: Insert the dual set positive/negative DC wires into PWR1 and 

PWR2 terminals (+ 

  pins 1, 9, - 

  pins 2, 10). Or insert the L/N AC 

wires into the PWR1 terminals (L 

  pin 1, N 

 pin 2). 

STEP 2

: To keep the DC or AC wires from pulling loose, use a 

screwdriver to tighten the wire-clamp screws on the front of the terminal 
block connector. 

 

LED Indicators 

The front panel of the PT switch contains several LED indicators. The 
function of each LED is described in the table below. 

LED 

Color 

State

Description 

System LEDs 

On 

System has passed self-diagnosis 

test on boot-up and is ready to run. 

GREEN 

Blinking System is undergoing the 

self-diagnosis test. 

STAT 

RED On 

System failed self-diagnosis on 

boot-up. 

On 

Power is being supplied to the main 

module’s power input PWR1. 

PWR1 

AMBER 

Off 

Power is not being supplied to the 

main module’s power input PWR1.

On 

Power is being supplied to the main 

module’s power input PWR2. 

PWR2 

AMBER 

Off 

Power is not being supplied to the 

main module’s power input PWR2.

On 

The corresponding PORT alarm is 

enabled and a user-configured event 

has been triggered. 

FAULT 

RED 

Off 

The corresponding PORT alarm is 

enabled and a user-configured event 

has not been triggered, or the 

corresponding PORT alarm is 

disabled. 

On 

This PT switch is the Master of this 

Turbo Ring. 

Blinking

This PT switch has become Ring 

Master of this Turbo Ring after the 

Turbo Ring was broken. 

MASTER 

GREEN 

Off 

This PT switch is not the Master of 

this Turbo Ring. 

COUPLER 

GREEN 

On 

When this PT switch enables the 

coupling function to form a back-up 

path. 

Off 

When this PT switch disables the 

coupling function. 

Mode LEDs 

On 

The corresponding module port’s 

link is active. 

Blinking The corresponding module port’s 

data is being transmitted. 

LNK/ACT

GREEN

Off 

The corresponding module port’s 

link is inactive. 

Off 

The corresponding module port’s 

data is being transmitted at 10 

Mbps. 

On 

The corresponding module port’s 

data is being transmitted at 100 

Mbps. 

SPEED 

GREEN

Blinking

The corresponding module port’s 

data is being transmitted at 

1000 Mbps. 

On 

The corresponding module port’s 

data is being transmitted in full 

duplex mode. 

FDX/HDX

GREEN

Off 

The corresponding module port’s 

data is being transmitted in half 

duplex mode. 

On 

The corresponding module’s port is 

the ring port of this PT switch. 

RING 

PORT 

GREEN

Off 

The corresponding module’s port is 

not the ring port of this PT switch. 

On 

The corresponding module’s port is 

the coupler port of this PT switch. 

COUPLER 

PORT

 

GREEN

Off 

The corresponding module’s port is 

not the coupler port of this PT 

switch. 

* Slot 2 (M2) is mainly used for Gigabit modules. If 100BaseFX modules 
are used in Slot 2 (M2), the modules will not support “Far End Fault”. 
The Link/ACT LED indicator will stay at “Green (ON)” status when 
Fiber TX cable is unplugged. 

Specifications 

Technology 

Standards 

IEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.3x, 
802.1D, 802.1W, 802.1Q, 802.1p, 802.1X, 802.3ad

Flow control 

IEEE 802.3x flow control, back pressure flow 
control 

Interface 

Fast Ethernet 

Slot 1 (M1) for any combination of 6-, 7-, or 8-port 
PM-7200 fast Ethernet modules with 
10/100BaseT(X) or 100BaseFX (SC/ST connector) 
Slot 2 (M2) for a 1- or 2-port interface modules 
with 100BaseFX (SC/ST connector) 

Gigabit Ethernet 

Slot 2 (M2) for 2-port PM-7200 Gigabit Ethernet 
combo module with 100/1000BaseT(X) or 
1000BaseSFP slots (Slot 2 does not support 10M 
FDX/HDX) 

Console RS-232 

(RJ45) 

System LED 
Indicators 

STAT, PWR1, PWR2, FAULT, MASTER, 
COUPLER

 

Module LED 
Indicators 

LNK/ACT, FDX/HDX, RING PORT, COUPLER 
PORT, SPEED

 

Alarm Contact

 

One relay output with current carrying capacity of 
3A @ 30 VDC or 3A @ 240 VAC

 

Optical Fiber (100BaseFX)

 

Distance Multi-mode 

0 to 5 km, 1300 nm (50/125

μ

m, 800 MHz*km) 

0 to 4 km, 1300 nm (62.5/125

μ

m, 500 MHz*km) 

 

Single-mode 
0 to 40 km, 1310 nm (9/125

μ

m, 3.5 PS/(nm*km)) 

Min. TX Output 

Multi-mode: -20 dBm; single-mode: -5 dbm

 

 

Max. TX Output 

Multi-mode: -10 dBm; single-mode: 0 dbm

 

 

RX Sensitivity 

Multi-mode: -32 dBm; single-mode: -34 dbm

 

 

Power 

Input Voltage 

24/48 VDC (9 to 60 V), or 110/220 VDC/VAC (88 
to 300 VDC and 85 to 264 VAC) 

Input Current 

Max. 0.81A @ 24 VDC 
Max. 0.42A @ 48 VDC 
Max. 0.17/0.10 @ 110/220 VDC 
Max. 0.20/0.12 @ 110/220 VAC 

Physical Characteristics 

Housing 

IP 30 protection, metal case 

Dimensions  
(W x H x D) 

266.7 x 44 x 195 mm (10.5 x 1.73 x 7.68 in.) 

Weight 2200g 

Environmental Limits

 

Operating Temp.

-40 to 85°C (-40 to 185°F) 
Cold start of min. 100 VAC at -40

°

Storage Temp. 

-40 to 85°C (-40 to 185°F) 

Ambient Relative 
Humidity. 

5 to 95% (non-condensing) 

Regulatory Approv

al

Safety EN60950-1 

(Pending) 

Power 
Automation 

IEC 61850-3, IEEE 1613 

Road Traffic 

NEMA TS2 

Rail Traffic 

EN50121-4 (Pending) 

Maritime 

DNV (Pending), GL (Pending) 

EMI 

FCC Part 15, CISPR (EN55022) class A 

Warranty

 

5 years 

 

 

Click here for online support: 

www.moxa.com/support 

The Americas:  +1-714-528-6777 (toll-free: 1-888-669-2872) 

Europe:  +49-89-3 70 03 99-0 

Asia-Pacific: +886-2-8919-1230 

China: +86-21-5258-9955 (toll-free: 800-820-5036) 

 

©

 2008 Moxa Inc., all rights reserved. 

Reproduction without permission is prohibited. 

 

Отзывы: