Gigabit Ethernet Interface Modules (for slot 4) 

40.7

86.6

86.6

40.7

PM-7200-4GTXSFP

PM-7200-2GTXSFP

40.7

86.6

PM-7200-1BNC2MST-PTP

 

Rack Mounting 

Use four screws to attach the PT switch to a standard rack. 

 

NOTE  Two additional rack-mount ears can be ordered as an option. Use 

them to secure the rear of the chassis in high-vibration 
environments. 

 

Wiring Requirements 

 

WARNING 

Safety First!

 

Be sure to disconnect the power cord before installing and/or 
wiring your Moxa PowerTrans Switch. 
Calculate the maximum possible current in each power wire and 
common wire. Observe all electrical codes dictating the 
maximum current allowable for each wire size. 
If the current goes above the maximum ratings, the wiring could 
overheat, causing serious damage to your equipment. 

 

Grounding Moxa PowerTrans Switch 

Grounding and wire routing help limit the effects of noise due to 
electromagnetic interference (EMI). Run the ground connection from the 
ground screw to the grounding surface prior to connecting devices. 

Wiring the Power Inputs 

The PT series of switches supports dual redundant power supplies: 
“Power Supply 1 (PWR1)” and “Power Supply 2 (PWR2)”. The connections 
for PWR1, PWR2 and the RELAY are located on the terminal block. The 
front view of the terminal block connectors are shown below. 

 

- 4 - 

Содержание PowerTrans PT-7728-PTP

Страница 1: ...2010 Moxa Inc All rights reserved Reproduction without permission is prohibited P N 1802077280030 PT 7728 PTP Hardware Installation Guide Moxa PowerTrans Switch First Edition August 2010...

Страница 2: ...2 rack mount ears Panel Layout M3 M4 4 3 M1 M2 Front view Front Cabling Front view Rear Cabling Rear view Front Cabling Rear view Rear Cabling 7 8 M4 M3 M2 M1 PT 7728 PTP CONSOLE 1 2 3 4 1 2 1 2 3 4 1...

Страница 3: ...PM 7200 4SSC2TX 96 8 96 8 96 8 PM 7200 6MSC PM 7200 6SSC PM 7200 2MSC4TX PM 7200 2SSC4TX PM 7200 4MST2TX 96 8 96 8 96 8 PM 7200 6MST PM 7200 2MST4TX PM 7200 1MST6TX 40 7 40 7 40 7 40 7 40 7 40 7 40 7...

Страница 4: ...wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious dam...

Страница 5: ...Y circuit will be closed Wiring the Redundant Power Inputs Each PT switch has two sets of power inputs power input 1 and power input 2 STEP 1 Insert the dual set positive negative DC wires into PWR1 a...

Страница 6: ...nfigured event has been triggered FAULT RED Off The corresponding PORT alarm is enabled and a user configured event has not been triggered or the corresponding PORT alarm is disabled On This PT switch...

Страница 7: ...g or chain port of this PT switch RING CHAIN PORT GREEN Off The corresponding module s port is not the ring or chain port of this PT switch On The corresponding module s port is the coupler port of th...

Страница 8: ...eristics Housing IP 30 protection metal case Dimensi W x H x ons D mm 17 32 x 1 73 x 12 76 in 440 x 44 x 325 Weight 5900 g Installation 19 rack mounting Regulatory Approvals Safety UL60950 1 CSA C22 2...