WARNING 

 

This equipment is intended to be used in a Restricted 
Access Location, such as a dedicated computer room, 
where access can only be gained by SERVICE PERSONS or 
by USERS who have been instructed about the fact that the 
metal chassis of the equipment is extremely hot and may 
cause burns. 

 

Service persons or users should pay special attention and 
take special precautions before handling this equipment. 

 

Only authorized, well-trained professionals should be 
allowed to access the restricted access location. Access 
should be controlled by the authority responsible for the 
location with lock and key or a security identity system. 

 

External Metal Parts are Hot!!

 Pay special attention or 

use special protection before handling this equipment. 

 

Wiring Requirements 

 

WARNING 

Safety First!

 

Be sure to disconnect the power cord before installing and/or 
wiring the OnCell 3120-LTE-1 device. 

 

Read and Follow These Guidelines 

 

Use separate paths to route wiring for power and devices. If power 
wiring and device wiring paths must cross, make sure the wires are 
perpendicular at the intersection point. 
 

NOTE 

Do not run signal or communications wiring and power wiring in 
the same wire conduit. To avoid interference, wires with 
different signal characteristics should be routed separately. 

 

 

 

You can use the type of signal transmitted through a wire to 
determine which wires should be kept separate. The rule of thumb 
is that wiring with similar electrical characteristics can be bundled 
together. 

 

Keep input wiring and output wiring separate. 

 

It is strongly advised that you label wiring to all devices in the 
system when necessary. 

 

 

ATTENTION 

This product is intended to be supplied by a Listed Power Unit 
marked “Class 2” or “LPS” and rated O/P: 9.6 W (12 V/0.78 A 
to 48 V/0.2 A). 

 

 
 
 

Содержание OnCell 3120-LTE-1

Страница 1: ...port Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 0...

Страница 2: ...y The OnCell 3120 LTE 1 also comes with a 3 in 1 serial port for serial over LTE cellular network communication making it suitable for collecting and exchanging data with serial Ethernet devices Packa...

Страница 3: ...3120 LTE 1 to a computer See the 10 100BaseT X Ethernet Port Connection section below for detailed instructions If the LAN LED indicator on the OnCell 3120 LTE 1 lights up it means a connection has b...

Страница 4: ...ular antenna port 3 10 100 Base T X Ethernet port 1 RJ45 4 10 100 Base T X Ethernet port 2 RJ45 5 USB port 6 DB9 serial port 7 LED display 8 Reset button 9 Console port reserved for engineering use 10...

Страница 5: ...he back panel Mount the OnCell 3120 LTE 1 Series on corrosion free mounting rails that meet the EN 60715 standard Installation STEP 1 Insert the upper lip of the DIN rail into the top hook of the DIN...

Страница 6: ...OnCell 3120 LTE 1 device with wall mount plates attached as a guide to mark the correct locations of the 4 screws The heads of the screws should be less than 6 0 mm in diameter and the shafts should b...

Страница 7: ...y First Be sure to disconnect the power cord before installing and or wiring the OnCell 3120 LTE 1 device Read and Follow These Guidelines Use separate paths to route wiring for power and devices If p...

Страница 8: ...e zero If the potential difference is NOT zero the product could be permanently damaged SIM Card Socket The OnCell 3120 LTE 1 comes with two nano SIM card sockets for cellular communication The nano S...

Страница 9: ...e OnCell 3120 LTE 1 ATTENTION Before connecting the OnCell 3120 LTE 1 to the DC power inputs make sure that the DC power source voltage is stable Communication Connections 10 100Base T X Ethernet Port...

Страница 10: ...3120 LTE 1 The function of each LED is described in the table below LED Color Behavior Function SYS 2 LEDs Green Power On System startup is complete and the system is in operation Off No power is sup...

Страница 11: ...r signal strength Specifications Input Current 0 8 A max Input Voltage 9 to 36 VDC Power Consumption 5 W typ Operating Temperature Standard Models 0 to 55 C 32 to 131 F Wide Temp Models 30 to 70 C 22...

Страница 12: ...NFPA 70 National Electrical Code Article 810 and Canada Canadian Electrical Code Section 54 ATTENTION For EXPLOSION PROOF applications the OnCell 3120 LTE 1 is designed and certified to meet ATEX and...

Страница 13: ...2 I SH 01 2013 11 I SH 02 2014 10 IEC 60079 15 4th Edition 2010 01 I SH 01 2016 09 5 Conditions for Safe Usage These devices shall be mounted in a suitable tool accessible ATEX IECEx certified enclosu...

Отзывы: