background image

- 4 - 

 

Name 

Color  Function 

WLAN 

Green 

Steady on:  Wireless enabled 
Blinking:  The NPort can’t establish a WLAN 

connection with AP (Infrastructure) or 
station (Ad-Hoc) 

Off 

Wireless not enabled 

Serial 1 
Serial 2 

Orange  The serial port is receiving data 

Green  The serial port is transmitting data 

Off 

No data is flowing to or from the serial port 

Signal 

Strength 

Red 

1 Red - 

The signal strength (RSSI) is lower 
than -88 dBm 

2 Red - 

The signal strength (RSSI) is between   
- 87 to -79 dBm 

Green 

3 Green -  The signal strength (RSSI) is between   

-78 to -68 dBm 

4 Green -  The signal strength (RSSI) is between   

-67 to -60 dBm 

5 Green -  the signal strength (RSSI) is between   

-59 to -45 dBm 

Pull-High/Low Resistors and Terminal Resistor 

for RS-422/485 

 

You may need to set the pull-
high/low resistors when 
termination resistors are used in 
certain RS-422 or RS-485 
environments. 

 

S2(Serial 1) 
S3(Serial 2) 

DIP 1 

DIP 2 

DIP 3 

DIP 4 

Pull-high 

Resistor 

Pull-low 

Resistor 

Terminal 

Resistor 

Reserved 

ON 

1 kΩ

 

1 kΩ

 

120 Ω

 

– 

OFF (Default) 

150 kΩ

 

150 kΩ

 

N/A 

– 

S3 is for the NPort W2250A only. 

Содержание NPort W2150A

Страница 1: ...oxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0...

Страница 2: ...and WLAN Per port offline port buffering and serial data log Dual power inputs via a power jack and terminal block Package Checklist Before installing the NPort W2150A W2250A device server verify that...

Страница 3: ...ct to hold the reset button down for five seconds to load the factory defaults Name Color Function End Panel LED Indicators Ethernet Orange 10 Mbps Ethernet connection Green 100 Mbps Ethernet connecti...

Страница 4: ...2 Red The signal strength RSSI is between 87 to 79 dBm Green 3 Green The signal strength RSSI is between 78 to 68 dBm 4 Green The signal strength RSSI is between 67 to 60 dBm 5 Green the signal streng...

Страница 5: ...to 75 C 40 to 167 F the PWR 12150 plug type SA T series for your reference Software Installation Information For the NPort s configuration the default IP address of the NPort is LAN Static IP 192 168...

Страница 6: ...imilar program you may download Moxa s program called PComm Lite to test whether the device is good or not Pin Assignments and Cable Wiring Pin RS 232 RS 422 4w RS 485 2w RS 485 1 DCD TxD A 2 RXD TxD...

Страница 7: ...7 EMC CE EN 55032 Class A EN 55035 ETSI EN 301 489 17 ETSI EN 301 489 1 FCC FCC Part 17 Subpart B Class A FCC Part 15 Subpart B Class A Safety UL UL 60950 1 LVD EN 60950 1 DSPR ARIB STD 33 ARIB STD 66...

Отзывы: