- 7 - 

 

Grounding the NAT-102 Series 

Grounding and wire routing help limit the effects of noise due to 
electromagnetic interference (EMI). Run the ground connection from 
the ground screw (M4 type) to the grounding surface prior to 
connecting devices. 
The grounding wire must be connected to the grounding screw using a 
cable lug. The grounding cable must have a cross-sectional area that is 
the same or larger than the 0.08 mm² (28 AWG) to 1.31 mm² (16 
AWG) terminal input conductor wire. 

 

ATTENTION 

This product is intended to be mounted to a well-grounded 
mounting surface such as a metal panel. 

 

Wiring the Power Inputs 

The NAT-102 Series has one power input. The top and side views of the 
terminal block connector are shown below. 

 

Top View 

 

Right View 

STEP 1: 

Use a small flat-blade screwdriver 
to press a wire locker. 

STEP 2: 

Insert a positive/negative DC wire 
into the V+/V- 

terminals 

respectively. 

STEP 3: 

Release the wire locker and check 
whether the wire is fixed. 
 
The  input terminal block (J1) 
should be installed using 16-28 
AWG wires with 8-9 mm of the 
conductor insulation stripped. 

The power cord adapter should be connected to a socket outlet with an 
earthing connection. The power cord and adapter must comply with 
Class II construction. 
This product is intended to be supplied by a UL Listed Power Adapter or 
DC power source marked ‘L.P.S’ or ‘Limited Power Source’, rated 12 to 
48 VDC, 0.196 A (min.), and Tma 75°C (min.). If you require further 
assistance, please contact your Moxa representative. 

Communication Connections 

Each NAT-102 Series has two types of communication ports: 

 

1 Type-C console port (RS-232 interface, baudrate: 115200, 8-N-1) 

Содержание NAT-102 Series

Страница 1: ...01024010 1802001024010 NAT 102 Series Quick Installation Guide Moxa Industrial NAT Device Version 1 0 November 2021 Technical Support Contact Information www moxa com support 2021 Moxa Inc All rights...

Страница 2: ...ial NAT device 1 USB C to DB9 cable Quick installation guide printed Protective caps for unused ports Warranty card Features Complete NAT functionality for speeding up Industry 4 0 connectivity Enhanc...

Страница 3: ...R LED indicator 2 STATE LED indicator 3 LEARNING LED indicator 4 LOCKDOWN LED indicator 5 10 100 Mbps copper external port 6 10 100 Mbps copper internal port Top Panel 1 Grounding screw 2 Terminal blo...

Страница 4: ...ting kit Mounting Dimensions DIN rail Mounting In the package the metal DIN rail mounting kit is fixed to the back panel of the NAT 102 Series Mount the NAT 102 Series on a corrosion free mounting rai...

Страница 5: ...on the DIN rail kit with a screwdriver STEPS 2 3 Slightly pull the NAT 102 Series forward and lift it up to remove it from the mounting rail Wall Mounting For some applications you will find it conve...

Страница 6: ...l electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Please re...

Страница 7: ...n below Top View Right View STEP 1 Use a small flat blade screwdriver to press a wire locker STEP 2 Insert a positive negative DC wire into the V V terminals respectively STEP 3 Release the wire locke...

Страница 8: ...nect to Ethernet enabled devices Most users will choose to configure these ports for Auto MDI MDI X mode in which case the port s pinouts are adjusted automatically depending on the type of Ethernet c...

Страница 9: ...passed the self diagnosis test on boot up and is ready to run Blinking Device reset is in progress blinking once per second Off The system failed the self diagnosis test on boot up LEARN Amber Blinki...

Страница 10: ...de Dist Taoyuan City 334004 Taiwan Hazardous Location EN IEC 60079 0 2018 EN IEC 60079 7 2015 A1 2018 Special Use Conditions The equipment shall only be used in an area of at least pollution degree 2...

Отзывы: