Specifications 

Power Input 

Dual 20 to 60 VDC (for DC models); 
or dual 100 to 240 VAC,  
47 to 63 Hz (for AC models) 

Power Consumption 
  MGate MB3660-8-2AC 
  MGate MB3660-8-2DC 
  MGate MB3660-16-2AC 
  MGate MB3660-16-2DC 
  MGate MB3660-8-J-2AC 
  MGate MB3660-16-J-2AC 
  MGate MB3660I-8-2AC 
  MGate MB3660I-16-2AC 

 
144 mA/110 V, 101 mA/220 V 
312 mA/24 V, 156 mA/48 V 
178 mA/110 V,120 mA/220 V 
390 mA/24 V, 195 mA/48 V 
111 mA/110 V, 81 mA/220 V 
133 mA/110 V, 92 mA/220 V 
100-240 VAC, 50/60 Hz, 310 mA (max.) 
100-240 VAC, 50/60 Hz, 310 mA (max.) 

Operating Temperature 

0 to 60°C (32 to 140°F) 

Storage Temperature 

-40 to 85°C (-40 to 185°F) 

Operating Humidity 

5 to 95% RH 

Dimensions (W x D x H) 

440 x 197.5 x 45.5 mm 
(17.32 x 7.78 x 1.79 in) 

Fault Relay Circuit 

3-pin circuit with current carrying 
capacity of 2 A @ 30 VDC 

 

Содержание Mgate MB3660

Страница 1: ...Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fa...

Страница 2: ...items 1 MGate MB3660 8 or MB3660 16 gateway 1 RJ45 to DB9 female serial cable for console setting 2 L shaped brackets for wall mounting 2 AC power cords for AC models Quick installation guide Warrant...

Страница 3: ...res the MGate MB3660 8 has 8 DB9 RJ45 ports for transmitting serial data and the MGate MB3660 16 has 16 DB9 RJ45 ports for transmitting serial data The MGate MB3660I series gateways provide 2 kV seria...

Страница 4: ...BOOTP server did not respond properly or a relay output occurred Green Steady on Power is on and unit is functioning normally Blinking Unit is responding to the locate function Off Power is off or po...

Страница 5: ...e the cover The sequence from right to left is port 1 to port 16 To add a 120 termination resistor set switch 3 on the port s assigned DIP switch to ON set switch 3 to OFF the default setting to disab...

Страница 6: ...e Serial Ports Pin RS 232 RS 422 RS 485 4W RS 485 2W 1 DCD TxD A 2 RxD TxD B 3 TxD RxD B Data B 4 DTR RxD A Data A 5 GND GND GND 6 DSR 7 RTS 8 CTS 9 RJ45 Serial Ports Pin RS 232 RS 422 RS 485 4W RS 48...

Страница 7: ...16 2AC 144 mA 110 V 101 mA 220 V 312 mA 24 V 156 mA 48 V 178 mA 110 V 120 mA 220 V 390 mA 24 V 195 mA 48 V 111 mA 110 V 81 mA 220 V 133 mA 110 V 92 mA 220 V 100 240 VAC 50 60 Hz 310 mA max 100 240 VA...

Отзывы: