Moxa Technologies MGate MB3280 Скачать руководство пользователя страница 3

- 3 - 

Hardware Introduction 

As shown in the following figures, the MGate MB3280 has two DB9 male 
ports for transmitting serial data. 

 

Reset Button—

The reset button is used to load factory defaults. Using 

a pointed object such as a straightened paper clip to hold the reset 
button down for five seconds. Release the reset button when the Ready 
LED stops blinking in order to load the factory defaults. 

LED Indicators

—Four LED indicators are located on the top panel:

 

Name 

Color 

Function 

Ready 

Red 

Steady on:  Power is on and the unit is booting up. 
Blinking: 

IP conflict exists, or DHCP or BOOTP 
server is not responding properly. 

Green  Steady on:  Power is on and the unit is functioning 

normally. 

Blinking: 

Unit has been found by the Location 
command in MGate Manager. 

Off 

Power is off or power error condition exists. 

Ethernet  Orange  10 Mbps Ethernet connection. 

Green  100 Mbps Ethernet connection. 
Off 

Ethernet cable is disconnected or has a short. 

P1/P2 

Orange  Unit is receiving data from device. 
Green  Unit is transmitting data to device. 
Off 

No data is being exchanged with device. 