MGate 5134 Series User Manual
Version 1.0, September 2022
www.moxa.com/products
© 2022 Moxa Inc. All rights reserved.
Страница 1: ...MGate 5134 Series User Manual Version 1 0 September 2022 www moxa com products 2022 Moxa Inc All rights reserved...
Страница 2: ...thout warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products...
Страница 3: ...T IO Device Settings 24 Diagnostics 28 Diagnostics Protocol Diagnostics 28 Diagnostics Protocol Traffic 30 Diagnostics Event Log 30 Diagnostics Tag View 34 Diagnostics Network Connections 35 Diagnosti...
Страница 4: ...ces into a PROFINET network use the MGate 5134 as a Modbus client to collect data and exchange data with PROFINET host All models are protected by a rugged and compact metal housing are DIN rail mount...
Страница 5: ...d to a 10 Mbps Ethernet network The Ethernet LED will flash when Ethernet packets are being transmitted or received Installing DSU Software If you do not know the MGate gateway s IP address when setti...
Страница 6: ...ough Ethernet or verify the MGate s status Use a web browser such as Google Chrome to connect to the MGate using the HTTPS protocol When the MGate gateway appears on the DSU device list select the gat...
Страница 7: ...w microSD card 2 Power on the MGate 3 The configuration will be copied from the MGate to the microSD card 4 Power off the MGate and insert the microSD card to the other MGate 5 Power on the second MGa...
Страница 8: ...eshooting This chapter provides a quick overview of how to configure the MGate 5134 by web console System Dashboard This page gives a system dashboard of the MGate 5134 gateway You can change your pas...
Страница 9: ...phanumeric string optional You can include additional description about the device such as function and location Time Settings The MGate has a built in real time clock for time calibration functions F...
Страница 10: ...se this setting to manually adjust the time 1900 1 1 2037 12 31 or sync with the browser time Auto Specify the IP or domain of the time server to sync with E g 192 168 1 1 or time stdtime gov tw This...
Страница 11: ...ccept NTP messages from the time server The MGate s dispersion is 1 second You must configure your time server with a dispersion value lower than 1 sec for the NTP process to complete System Settings...
Страница 12: ...ails to respond the device will automatically switch to the backup LAN ETH2 IP Configuration DHCP Static IP Select Static IP if you are using a fixed IP address Select the DHCP option if you want the...
Страница 13: ...figure the baudrate parity data bits and stop bits before using the serial interface for the Modbus RTU ASCII protocol Incorrect settings will cause communication failures Parameter Value Description...
Страница 14: ...on and off on completion of the transmission RTS on delay 0 to 100 ms Only available for the RS 232 mode to implement the RTS Toggle function RTS off delay 0 to 100 ms Only available for the RS 232 mo...
Страница 15: ...ers in SNMP for two levels of access control read only and read write The access level is indicated in the value of the Authority field For example Read only authentication mode allows you to configur...
Страница 16: ...ate will disable SNMPv3 Each Authentication Failure Timeout min 1 to 1440 default 10 Specifies a timeout period when enabling the Timeout for authentication failure function Account Disabled Time Inte...
Страница 17: ...5134 Series User Manual 17 System Settings SNMP Settings SNMP Trap Parameters Description Server IP SNMP server IP address or domain name Port SNMP server IP Port Trap Version Disable SNMPv1 SNMPv2 S...
Страница 18: ...Modbus command tables on this page The MGate supports csv file import export for Modbus settings it is easy to use when you back up the settings or during installation stage Click TCP or the serial po...
Страница 19: ...imes out Response Timeout 10 to 120000 ms 1000 Based on the Modbus standard the device manufacturer defines the time a slave device takes to respond to a request A Modbus master can be configured to w...
Страница 20: ...eter Value Default Description Device Name Alphanumeric string Max 32 characters Slave IP 0 0 0 0 to 255 255 255 255 0 0 0 0 The IP address of a remote slave device Slave Port 1 to 65535 502 The TCP p...
Страница 21: ...rver what kind of action to perform Trigger Cyclic Data Change Disable Disable The command was never sent Cyclic The command is sent cyclically at the interval specified in the Poll Interval parameter...
Страница 22: ...tion to the other side server slave fails the gateway cannot receive data but the gateway will continuously send output data to the Modbus TCP server device To avoid problems in this case the MGate ca...
Страница 23: ...ate 5134 Series User Manual 23 Step 3 Quick review result click DONE to finish It is convenient if you already backed up a frequently used meter profile just import or export one Modbus device CSV fil...
Страница 24: ...emember to click GO TO APPLY SETTING and press the APPLY button at the bottom right hand side corner Protocol Settings PROFINET IO Device Settings You can configure the PROFINET IO Device setting on t...
Страница 25: ...ser Manual 25 Parameter Value Description Device Name alphanumeric string Enter the PROFINET server name if you type the name incorrectly the connection will fail Click on the Application Relation but...
Страница 26: ...rameter Value Description Slot number 1 to 128 Slot number in PROFINET IO Controller program develops environment setting Type Input Output Input or output type to PROFINET IO Controller Slot Name alp...
Страница 27: ...n setting the PROFINET IO controller system Typically users waste a lot of time on importing the MGate 5134 general GSDML files and setting the IO modules respectively If we import the specified GSDML...
Страница 28: ...Protocol Diagnostics Diagnostics Protocol Diagnostics Modbus RTU ASCII Diagnostic The MGate provides status information for Modbus RTU ASCII TCP EtherNet IP troubleshooting Verify data or packet count...
Страница 29: ...MGate 5134 Series User Manual 29 Diagnostics Protocol Diagnostics Modbus TCP Diagnostics Diagnostics Protocol Diagnostics PROFINET Diagnostics...
Страница 30: ...nication traffic for all protocols These logs present the data in an intelligent easy to understand format with clearly designated fields including source destination function code and data Save the c...
Страница 31: ...licking the channel name After changing the settings please remember to SAVE it Event Group Description System Start system User trigger reboot Power input failure NTP update failure Network IP confli...
Страница 32: ...log Log Capacity Warning When the log amount exceeds the warning Warning By SNMP Trap Email Remote Log Settings Remote Log Settings Description Syslog Server IP IP address of a server that will recor...
Страница 33: ...domain name or IP address Port The mail server s IP port Security Connection TLS STARTTLS STARTTLS None None Username This field is for your mail server s username if required Password This field is f...
Страница 34: ...is page displays the tag live value generated by field devices and updates the values periodically It is an easy and useful tool if you want to check whether the MGate receives the correct data from f...
Страница 35: ...related information including protocol address and state Diagnostics Ping This network testing function is available only in the web console The MGate gateway will send an ICMP packet through the net...
Страница 36: ...nual 36 Diagnostics LLDP You can see LLDP related information including Port Neighbor ID Neighbor Port Neigh Port Description and Neighbor System Also you can adjust the transmit interval for LLDP by...
Страница 37: ...o edit the account Parameters Value Description Group Administrator Operator Guest Users can change the password for different accounts The MGate provides three build in account groups administrator o...
Страница 38: ...MGate 5134 Series User Manual 38 Security Account Management Groups Three MGate build in types of groups are shown you can also create your own group by clicking CREATE...
Страница 39: ...d side of the web console you can select different permissions for a new group Displays will not show the page on the right hand side menu Security Account Management Password Policy Parameter Value D...
Страница 40: ...et button Ping Service Enable Disable Disabling this service will block ping requests from other devices SD Card Enable Disable Disabling this service will deactivate the SD card function for backup a...
Страница 41: ...Security Allow List These settings are used to restrict access to the MGate by the IP address Only IP addresses on the list will be allowed to access the device Notice the restriction includes config...
Страница 42: ...ers can select from several options to enable DoS Defense to fend off cybersecurity attacks A denial of service DoS attack is an attempt to make a machine or a network resource unavailable Users can s...
Страница 43: ...imes 1 to 10 default 5 You can specify the maximum number of failures reties if exceed the retry times MGate will lock out for that account login Reset Period min 1 to 1440 default 10 You can specify...
Страница 44: ...The number of users that can access the MGate at the same time Auto logout setting min 1 to 1440 default 1440 Sets the auto logout period Security Certificate Management Use this function to load the...
Страница 45: ...king up configurations for system recovery The export function allows you to export configuration files that can be imported onto other gateways to restore malfunctioning systems within minutes Troubl...
Страница 46: ...e MGate will erase the old firmware to make room for the new firmware to flash memory If you power off the MGate and end the progress the flash memory will contain corrupted firmware and the MGate wil...
Страница 47: ...data will be stored in the gateway s memory and will be retrieved by the client e g PLC which is not aware that the slave device is not providing up to date data To handle this situation the MGate pr...
Страница 48: ...MXstudio suite in the MGate includes MXconfig and MXview which are used for the mass configuration of network devices and monitoring network topology respectively The following functions are supported...
Страница 49: ...e ipOutRequests icmpInTimestamps ifInOctets ipOutDiscards icmpTimestampReps ifInUcastPkts ipOutNoRoutes icmpInAddrMasks ifInNUcastPkts ipReasmTimeout icmpInAddrMaskReps ifInDiscards ipReasmReqds icmpO...
Страница 50: ...talSetVars tcpConnLocalAddress snmpInGetRequests tcpConnLocalPort snmpInGetNexts tcpConnRemAddress snmpInSetRequests tcpConnRemPort snmpInGetResponses tcpInErrs snmpInTraps tcpOutRsts snmpOutTooBigs s...