background image

- 4 - 

LED Indicators 

The following table describes the function of the LED indicators located 
on the front and rear panels: 

LED Name 

Status 

Description 

Power 

 

Green  Power is on and computer is 

functioning normally 

Off 

Power is off 

Storage 1 (mSATA) 

 

Yellow  Blinking: Data transmission 

Off 

No data transmission. 

LAN 1/2/3/4 

(on connectors)

 

Green 

Steady On: 100 Mbps Ethernet link 
Blinking: Data is being transmitted 

Yellow  Steady On: 1000 Mbps Ethernet link 

Blinking: Data is being transmitted 

Off 

10 Mbps Ethernet link or LAN is not 
connected 

Tx 1/2  

(serial ports) 

 

Green  Blinking: Data is being transmitted. 

Off 

No connection 

Rx 1/2 

(serial ports)

 

Yellow  Blinking: Data is being transmitted. 

Off 

No connection 

Dimensions 

 

Содержание MC-3201 Series

Страница 1: ...P N 1802032010010 1802032010010 MC 3201 Series Quick Installation Guide Version 1 0 July 2022 Technical Support Contact Information www moxa com support 2022 Moxa Inc All rights reserved ...

Страница 2: ... SSD expansion modules With compliance with the IEC 60945 and E10 standards the MC 3201 is sure to deliver stable and reliable system operation for marine and IIoT applications These certifications are issued to products to indicate their suitability for marine applications to allow them to be used in potentially hazardous environments Package Checklist Before installing the MC 3201 verify that th...

Страница 3: ... 3 Rear Panel MC 3201 TGL1 Front Panel Rear Panel ...

Страница 4: ...w Blinking Data transmission Off No data transmission LAN 1 2 3 4 on connectors Green Steady On 100 Mbps Ethernet link Blinking Data is being transmitted Yellow Steady On 1000 Mbps Ethernet link Blinking Data is being transmitted Off 10 Mbps Ethernet link or LAN is not connected Tx 1 2 serial ports Green Blinking Data is being transmitted Off No connection Rx 1 2 serial ports Yellow Blinking Data ...

Страница 5: ...i 90D Nylok STEP 2 Use two screws per bracket to attach the MC 3201 to a wall or cabinet Note Mounting the MC 3201 to a wall requires four screws Use the MC 3201 computer with the wall mounting brackets attached as a guide to mark the correct locations of the screws on the wall The heads of the screws should be at least 6 0 mm in diameter the shafts should be 3 5 mm in diameter with a minimum dept...

Страница 6: ...nnected to an outlet with an earthing connection ATTENTION The equipment MC 3201 TGL7 M S is intended to be supplied by the external power source UL listed IEC 60950 1 IEC 62368 1 which output complies with ES1 SELV output rating is 24 VDC 2 7 A min an ambient temperature 55 C minimum ATTENTION The equipment MC 3201 TGL1 S S is intended to be supplied by the external power source UL listed IEC 609...

Страница 7: ...Ports The serial ports use DB9 connectors Each port can be configured by software as a RS 232 RS 422 or RS 485 port The pin assignments for the ports are shown below Pin RS 232 RS 422 RS 485 4 wire RS 485 2 wire 1 DCD TxDA TxDA 2 RxD TxDB TxDB 3 TxD RxDB RxDB DataB 4 DTR RxDA RxDA DataA 5 GND GND GND GND 6 DSR 7 RTS 8 CTS USIM Slot The MC 3201 TGLX S model has four USIM slots for 5G LTE wireless I...

Страница 8: ...ate drive NOTE The storage disk should be installed and maintained by a skilled person To install a storage disk do the following Step 1 Unfasten two screws and remove the storage cover on the front panel of the MC 3201 Step 2 Slide the latch on the disk tray to the left and pull out the tray from the slot Step 3 Place the storage disk onto the tray Step 4 Fasten the four screws on the back of the...

Страница 9: ...C 3201 Ensure that you insert the tray into the plastic rails on both sides of the slot Step 6 Pull the latch on the tray to the right to secure the tray in the slot Step 7 Put back the cover on the storage slot and fasten the two screws to secure the cover in place ...