Moxa Technologies ioThinx 4500 Series Скачать руководство пользователя страница 4

- 4 - 

Installing the Covers on the First and Last Module 

Attach the covers to the first and last module to cover the modules' 
contacts. 

 

 

NOTICE 

Be sure to attach the covers to provide electrostatic discharge 
protection. 

 

Horizontal Installation 

Before installing the 
device, make sure there is 
enough space between the 
device and nearby items 
(walls, other devices, etc.) 
to ensure proper heat 
dissipation. 
To ensure that the device 
works properly, we 
suggest reserving the 
amount of space indicated 
in the adjacent figure. 

 

 

 

CAUTION 

DO NOT install the device vertically. If the device is installed 
vertically, the fanless heat dissipation design will not perform 
as intended. 

 

 
 

Содержание ioThinx 4500 Series

Страница 1: ... Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2019 Moxa Inc All rights reserved ...

Страница 2: ...e head CPU module making sure that the upper and lower rails are hooked together Step 2 Align the 45M module side by side with the head CPU module and then push the 45M module until it touches the DIN rail Next apply more force until the module clips to the DIN rail NOTE After the module is firmly attached to the DIN rail the module connections to the internal bus will be established ...

Страница 3: ...e lower part of the module Step 2 Push the top of the release tab to latch it and then pull the module out NOTE Electrical connections for the internal bus will be disconnected when removing the 45M module WARNING Be sure the power is off before removing modules to avoid damaging the equipment ...

Страница 4: ...stallation Before installing the device make sure there is enough space between the device and nearby items walls other devices etc to ensure proper heat dissipation To ensure that the device works properly we suggest reserving the amount of space indicated in the adjacent figure CAUTION DO NOT install the device vertically If the device is installed vertically the fanless heat dissipation design ...

Страница 5: ... 45MR 2600 2601 2606 must use an external power supply for field power Operating Temperature Standard Models 20 to 60 C 4 to 140 F Wide Temp Models 40 to 75 C 40 to 167 F Storage Temperature 40 to 85 C 40 to 185 F Attention 1 This device is only for indoor use in environments with pollution degree 2 2 The 45M has a ground pin on the back of the device For surge protection connect the DIN rail to e...

Отзывы: