Serial Programming Tools
Industio
CI-132 Series User’s Manual
4-9
There are 2 solutions to control RS-485 2-wire transmission.
Solution 1
The following model is common in RS-485 2-wire transmission.
sio_SetWriteTimeouts(port, 0);
/* Set sio_write() into block mode if for
Windows NT and Windows 95/98 */
sio_RTS(port, 1);
/* Turn on RTS signal. The RS-485
port is ready for transmitting data. */
sio_write(port, buff, 10);
/* Write 10 byte characters in "buff".
The
function
blocks
until
last
character transmitted */
sio_RTS(port, 0);
/* Turn off RTS signal. The RS-485
port is ready for receiving data. */
sio_read(port, buff, 10);
/* Read 10 bytes */
Solution 2
There is a dedicated RS-485 function in
PComm
or API-232 library. It
integrates the above functions of solution 1 regarding sending data as one.
sio_putb_x(port, buff, tick ); /*
1. Turn on RTS and ready for
transmitting data.
2. Send data.
3. Wait for tick time.
4. Turn off RTS and ready for
receiving data. */
For more information on these functions, please refer to
PComm
library on-line Help
file for Windows NT and Windows 95/98 or API-232.txt file for DOS, respectively.