– 4 –
– 5 –
– 6 –
www.moxa.com/support
The Americas: +1-714-528-6777 (toll-free: 1-888-669-2872)
Europe: +49-89-3 70 03 99-0
Asia-Pacific: +886-2-8919-1230
China: +86-21-5258-9955 (toll-free: 800-820-5036)
2013 Moxa Inc. All rights reserved.
Wiring the Redundant Power Inputs
The IKS-6324 switch has two sets of power input—power input 1
and power input 2.
STEP 1: Insert the dual set positive/negative DC wires into PWR1
and PWR2 terminals (+
pins 1, 9, -
pins 2, 10). Or
insert the L/N AC wires into the PWR1 terminals (L
pin
1, N
pin 2).
STEP 2: To keep the DC or AC wires from pulling loose, use a
screwdriver to tighten the wire-clamp screws on the front
of the terminal block connector.
LED Indicators
The front panel of the IKS-6324 switch
contains several LED indicators. The
function of each LED is described in the
table below.
LED
Color
State
Description
System LEDs
STAT
GREEN
On
System has passed self-diagnosis
test on boot-up and is ready to
run.
Blinking System is undergoing the
self-diagnosis test.
RED
On
System failed self-diagnosis on
boot-up.
PWR1
AMBER
On
Power is being supplied to the
main module’s power input PWR1.
Off
Power is not being supplied to the
main module’s power input PWR1.
PWR2
AMBER
On
Power is being supplied to the
main module’s power input PWR2.
Off
Power is not being supplied to the
main module’s power input PWR2.
FAULT
RED
On
System initiation has failed.
Off
System initiation was successful.
NOTE: Use the Mode push-button switch to cycle among the
LNK/ACT, SPEED, and FDX/HDX LEDs. The status of these three
settings is indicated by the LEDs for the various ports. The system
will switch to LNK/ACT automatically after 5 seconds.
LED
Color
State
Description
Mode LEDs
LNK/ACT GREEN
On
The corresponding module port’s
link is active.
Blinking The corresponding module port’s
data is being transmitted.
Off
The corresponding module port’s
link is inactive.
SPEED
GREEN
Off
The corresponding module port’s
data is being transmitted at 10
Mbps.
On
The corresponding module port’s
data is being transmitted at 100
Mbps.
Blinking
The corresponding module port’s
data is being transmitted at
1000 Mbps.
FDX/HDX GREEN
On
The corresponding module port’s
data is being transmitted at full
duplex.
Off
The corresponding module port’s
data is being transmitted at half
duplex mode.
* Slot 1 (M1) is mainly used for Gigabit modules. If 100BaseFX
modules are used in Slot 1 (M1), the modules will not support “Far
End Fault”. The Link/ACT LED indicator will stay at “Green (ON)”
status when Fiber TX cable is unplugged.
Specifications
Technology
Standards
IEEE802.3, 802.3u, 802.3ab, 802.3z, 802.3x
Flow Control
IEEE802.3x flow control, back pressure flow
control
Interface
Fast Ethernet
10/100BaseT(X) or 100BaseFX (SC/ST
connector)
Gigabit Ethernet
10/100/1000BaseT(X),
1000BaseSX/LX/LHX/ZX (SFP slot, LC
connector)
System LED
Indicators
STAT, PWR1, PWR2, FAULT
Module LED
Indicators
LNK/ACT, FDX/HDX, SPEED
Optical Fiber (100BaseFX)
Distance
Multi mode
0 to 5 km, 1300 nm (50/125
μm
, 800 MHz*km)
0 to 4 km, 1300 nm (62.5/125
μm
, 500
MHz*km)
Single mode
0 to 40 km, 1310 nm (9/125
μm
, 3.5
PS/(nm*km))
Min. TX Output
Multi mode: -20 dBm; Single mode: -5 dbm
Max. TX Output
Multi mode: -10 dBm; Single mode: 0 dbm
RX Sensitivity
-36 to -32 dBm (Single), -34 to -30 dBm (Multi)
Power
Input Voltage
Low Voltage: 24/48 VDC (9 to 60 V)
High Voltage: 110/250 VDC (88 to 300 V)
and 100/240 VAC (85 to 264 V)
Input Current
Max. 0.68A @ 24 VDC
Max. 0.35A @ 48 VDC
Max. 0.17/0.11A @ 110/220 VDC
Max. 0.33/0.23A @ 110/220 VAC
Connection
10-pin Terminal Block
Overload Current
Protection
6.3 A
Reverse Polarity
Protection
Present
Mechanical
Casing
IP 30 protection, metal case
Dimensions
(W x H x D)
440 x 44 x 254 mm (17.32 x 1.73 x 10.00 in.)
Weight
4300g
Installation
19-inch Rack Mounting
Environmental
Operating Temp. -40 to 75°C (-40 to 167°F) for -T models
Storage Temp.
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety
EN60950-1 (Pending)
Maritime
ABS/BV/CCS/DNV/GL/KR/LR/NKK/PR/RINA
(Pending)
Road Traffic
NEMA TS2 (Pending)
EMI
FCC Part 15, CISPR (EN55022) class A
Railway
EN50121-4 (Pending)
Shock & Vibration EN50155 (EN/IEC 61373, Category 1, Class B)
Warranty