background image

 

 

– 4 – 

– 5 – 

– 6 – 

 

www.moxa.com/support 

The Americas:   +1-714-528-6777 (toll-free: 1-888-669-2872) 

Europe:   +49-89-3 70 03 99-0 

Asia-Pacific:   +886-2-8919-1230 

China:   +86-21-5258-9955 (toll-free: 800-820-5036) 

 

 2013 Moxa Inc. All rights reserved. 

Wiring the Redundant Power Inputs 

The IKS-6324 switch has two sets of power input—power input 1 
and power input 2. 

 

STEP 1:  Insert the dual set positive/negative DC wires into PWR1 

and PWR2 terminals (+ 

 pins 1, 9, - 

 pins 2, 10). Or 

insert the L/N AC wires into the PWR1 terminals (L 

 pin 

1, N 

 pin 2). 

STEP 2:  To keep the DC or AC wires from pulling loose, use a 

screwdriver to tighten the wire-clamp screws on the front 
of the terminal block connector. 

LED Indicators 

 

The front panel of the IKS-6324 switch 
contains several LED indicators. The 
function of each LED is described in the 
table below. 

 

LED 

Color 

State 

Description 

System LEDs 

STAT 

GREEN 

On 

System has passed self-diagnosis 
test on boot-up and is ready to 
run. 

Blinking  System is undergoing the 

self-diagnosis test. 

RED 

On 

System failed self-diagnosis on 
boot-up. 

PWR1 

AMBER 

On 

Power is being supplied to the 
main module’s power input PWR1. 

Off 

Power is not being supplied to the 
main module’s power input PWR1. 

PWR2 

AMBER 

On 

Power is being supplied to the 
main module’s power input PWR2. 

Off 

Power is not being supplied to the 
main module’s power input PWR2. 

FAULT 

RED 

On 

System initiation has failed. 

Off 

System initiation was successful. 

NOTE: Use the Mode push-button switch to cycle among the 
LNK/ACT, SPEED, and FDX/HDX LEDs. The status of these three 
settings is indicated by the LEDs for the various ports. The system 
will switch to LNK/ACT automatically after 5 seconds. 

LED 

Color 

State 

Description 

Mode LEDs 

LNK/ACT  GREEN 

On 

The corresponding module port’s 
link is active. 

Blinking  The corresponding module port’s 

data is being transmitted. 

Off 

The corresponding module port’s 
link is inactive. 

SPEED 

GREEN 

Off 

The corresponding module port’s 
data is being transmitted at 10 
Mbps. 

On 

The corresponding module port’s 
data is being transmitted at 100 
Mbps. 

Blinking 

The corresponding module port’s 
data is being transmitted at 
1000 Mbps. 

FDX/HDX  GREEN 

On 

The corresponding module port’s 
data is being transmitted at full 
duplex. 

Off 

The corresponding module port’s 
data is being transmitted at half 
duplex mode. 

* Slot 1 (M1) is mainly used for Gigabit modules. If 100BaseFX 
modules are used in Slot 1 (M1), the modules will not support “Far 
End Fault”. The Link/ACT LED indicator will stay at “Green (ON)” 
status when Fiber TX cable is unplugged. 

Specifications 

Technology 
Standards 

IEEE802.3, 802.3u, 802.3ab, 802.3z, 802.3x 

Flow Control 

IEEE802.3x flow control, back pressure flow 
control 

Interface 
Fast Ethernet 

10/100BaseT(X) or 100BaseFX (SC/ST 
connector) 

Gigabit Ethernet 

10/100/1000BaseT(X), 
1000BaseSX/LX/LHX/ZX (SFP slot, LC 
connector) 

System LED 
Indicators 

STAT, PWR1, PWR2, FAULT 

Module LED 
Indicators 

LNK/ACT, FDX/HDX, SPEED 

Optical Fiber (100BaseFX) 
Distance 

Multi mode 
0 to 5 km, 1300 nm (50/125

μm

, 800 MHz*km) 

0 to 4 km, 1300 nm (62.5/125

μm

, 500 

MHz*km) 

 

Single mode 
0 to 40 km, 1310 nm (9/125

μm

, 3.5 

PS/(nm*km)) 

Min. TX Output 

Multi mode: -20 dBm; Single mode: -5 dbm 

Max. TX Output 

Multi mode: -10 dBm; Single mode: 0 dbm 

RX Sensitivity 

-36 to -32 dBm (Single), -34 to -30 dBm (Multi) 

Power 
Input Voltage 

Low Voltage: 24/48 VDC (9 to 60 V)   
High Voltage: 110/250 VDC (88 to 300 V)   
and 100/240 VAC (85 to 264 V) 

Input Current 

Max. 0.68A @ 24 VDC 
Max. 0.35A @ 48 VDC 
Max. 0.17/0.11A @ 110/220 VDC 
Max. 0.33/0.23A @ 110/220 VAC 

Connection 

10-pin Terminal Block 

Overload Current 
Protection 

6.3 A 

Reverse Polarity 
Protection 

Present 

Mechanical 
Casing 

IP 30 protection, metal case 

Dimensions   
(W x H x D) 

440 x 44 x 254 mm (17.32 x 1.73 x 10.00 in.) 

Weight 

4300g 

Installation 

19-inch Rack Mounting 

Environmental 
Operating Temp.  -40 to 75°C (-40 to 167°F) for -T models 
Storage Temp. 

-40 to 85°C (-40 to 185°F) 

Ambient Relative 
Humidity 

5 to 95% (non-condensing) 

Regulatory Approvals 
Safety 

EN60950-1 (Pending) 

Maritime 

ABS/BV/CCS/DNV/GL/KR/LR/NKK/PR/RINA 
(Pending) 

Road Traffic 

NEMA TS2 (Pending) 

EMI 

FCC Part 15, CISPR (EN55022) class A 

Railway 

EN50121-4 (Pending) 

Shock & Vibration  EN50155 (EN/IEC 61373, Category 1, Class B) 
Warranty 

5 years 

 