Moxa Technologies EtherDevice EDS-P206A-4PoE Series Скачать руководство пользователя страница 6

- 6 - 

Mounting Dimensions 

Unit = mm (inch) 

 

DIN-Rail Mounting 

The aluminum DIN-Rail attachment plate should already be fixed to the 
back panel of the EDS when you take it out of the box. If you need to 
reattach the DIN-Rail attachment plate, make sure the stiff metal spring 
is situated towards the top, as shown in the figures below. 
STEP 1: Insert the top of the 
DIN-Rail into the slot just 
below the stiff metal spring. 

STEP 2: The DIN-Rail attachment 
unit will snap into place as shown 
below. 

 

 

To remove the EDS from the DIN-Rail, reverse Steps 1 and 2 above. 

Содержание EtherDevice EDS-P206A-4PoE Series

Страница 1: ...m support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3...

Страница 2: ...ty and IP30 metal housing with LED indicators make the plug and play EDS P206A 4PoE switches reliable and easy to use NOTE Throughout this Hardware Installation Guide we use EDS as an abbreviation for...

Страница 3: ...s 1 Grounding screw 2 Terminal block for power input P1 P2 3 DIP switches 4 Power input P1 LED 5 Power input P2 LED 6 PoE LED 7 10 100BaseT X port 8 TP port s 10 100 Mbps LED 9 Model name 10 Screw hol...

Страница 4: ...EDS P206A 4PoE M SC ST 1 Grounding screw 2 Terminal block for power input P1 P2 3 DIP switches 4 Power input P1 LED 5 Power input P2 LED 6 PoE LED 7 10 100BaseT X port 8 TP port s 10 100 Mbps LED 9 M...

Страница 5: ...e EDS P206A 4PoE MM SC ST 1 Grounding screw 2 Terminal block for power input P1 P2 3 DIP Switches 4 Power input P1 LED 5 Power input P2 LED 6 PoE LED 7 10 100BaseT X port 8 TP port s 10 100 Mbps LED 9...

Страница 6: ...e box If you need to reattach the DIN Rail attachment plate make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN Rail into the sl...

Страница 7: ...the screws into the wall make sure the screw head and shank size are suitable by inserting the screw into one of the keyhole shaped apertures of the wall mounting plates Do not screw the screws in com...

Страница 8: ...s can be bundled together Keep input wiring and output wiring separated We strongly advise labeling the wiring to all devices in the system Grounding the EtherDevice Switch Grounding and wire routing...

Страница 9: ...thernet cables MDI Port Pinouts MDI X Port Pinouts 8 pin RJ45 Pin Signal 1 Tx 2 Tx 3 Rx 6 Rx Pin Signal 1 Rx 2 Rx 3 Tx 6 Tx PoE 10 100BaseT X Ethernet Port Connection PoE 10 100BaseT X ports located o...

Страница 10: ...ou are connecting devices I and II contrary to electrical signals optical signals do not require a circuit in order to transmit data Consequently one of the optical lines is used to transmit data from...

Страница 11: ...ce fails the other live source acts as a backup and automatically supplies all of the EDS s power needs DIP Switch Settings The default setting for each DIP Switch is OFF The following table explains...

Страница 12: ...port s 100 Mbps link is inactive PoE AMBER On The PoE device is connected by the IEEE 802 3af standard Blinking The PoE power is shut off because there is insufficient power Off No PoE power output o...

Страница 13: ...packet arrives at one of the switched ports a decision is made to either filter or forward the packet Packets with source and destination addresses belonging to the same port segment will be filtered...

Страница 14: ...rd Total Power Budget For the total power budget the EDS P206A 4PoE will have 62 W at 12 17 VDC input and 120 W at 18 57 VDC input The total power budget is the total amount of reserved PoE power base...

Страница 15: ...VDC power input PoE Output Power 15 4 W for 802 3af 30 W for 802 3at PoE Output Current 350 mA for 802 3af 600 mA for 802 3at Overload Current Protection at the port Supported PoE Pinout Mode A Pair 1...

Страница 16: ...185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals Safety UL508 EMI FCC Part 15 CISPR EN55032 class A EMS IEC 61000 4 2 ESD Contact 6 kV Air 8 kV IEC 61000 4 3 RS 20 V m 80 MH...