- 9 - 

Wiring the Relay Contact 

EDS-518A has two sets of relay outputs—relay 1 and relay 2. Each Relay 
Contact consists of the two contacts of the terminal block on EDS-518A’s 
top panel. You can refer to the next section for detailed instructions on 
how to connect the wires to the terminal block connector, and how to 
attach the terminal block connector to the terminal block receptor. 
In this section, we will explain the meaning of the two contacts used to 
connect the Relay Contact.   

 

FAULT: 

The two sets of relay 

contacts of the 6-pin terminal 
block connector are used to detect 
user-configured events. The two 
wires attached to the fault 
contacts form an open circuit 
when a user-configured event is 
triggered. If a user-configured 
event does not occur, the fault 
circuit remains closed. 

Wiring the Redundant Power Inputs 

EDS-518A has two sets of power inputs—power input 1 and power input 
2.The top two contacts and the bottom two contacts of the 6-pin terminal 
block connector on EDS’ top panel are used for EDS’ two digital inputs. 
The top and front views of one of the terminal block connectors are shown 
here. 

 

STEP 1: 

Insert the 

negative/positive DC wires into 
the V-/V+ terminals, respectively. 

STEP 2: 

To keep the DC wires 

from pulling loose, use a small 
flat-blade screwdriver to tighten 
the wire-clamp screws on the front 
of the terminal block connector. 

STEP 3: 

Insert the plastic terminal 

block connector prongs into the 
terminal block receptor, which is 
located on the EDS-518A’s top 
panel. 

 
 

 

Содержание EtherDevice EDS-518A Series

Страница 1: ... 2014 Moxa Inc All rights reserved P N 1802005180014 EDS 518A Series Hardware Installation Guide Moxa EtherDevice Switch Sixth Edition April 2014 ...

Страница 2: ...rranty Booklet RJ45 to DB9 Console port cable Protective caps for unused ports Panel mounting kit optional must order separately Optional Accessories DR 4524 45W 2A DIN Rail 24 VDC Power Supply with 85 to 264 VAC input DR 75 24 75W 3 2A DIN Rail 24 VDC Power Supply with 85 to 264 VAC input DR 120 24 120W 5A DIN Rail 24 VDC Power Supply with 88 to 132 VAC 176 to 264 VAC input by switch EDS SNMP OPC...

Страница 3: ...for PWR1 Relay 1 and Relay 2 6 10 100BaseT X ports 1 to 16 7 PWR 1 LED for power input 1 8 PWR 2 LED for power input 2 9 Fault LED 10 MSTR HEAD LED 11 CPLR TAIL LED 12 10 100 1000BaseT X port G2 13 10 100 1000BaseT X port G1 14 1000 Mbps LEDs 15 TP port s 100 Mbps LED 16 TP port s 10 Mbps LED 17 Model Name 18 Screw hole for Wall Mounting Kit 19 DIN Rail Kit ...

Страница 4: ...I 1 DI 2 and PWR 2 5 6 pin terminal block for PWR1 Relay 1 and Relay 2 6 10 100BaseT X ports 1 to 14 7 PWR 1 LED for power input 1 8 PWR 2 LED for power input 2 9 Fault LED 10 MSTR HEAD LED 11 CPLR TAIL LED 12 10 100 1000BaseT X Port G2 13 10 100 1000BaseT X Port G1 14 1000 Mbps LEDs 15 TP port s 100 Mbps LED 16 TP port s 10 Mbps LED 17 Model Name 18 100BaseFX Port 16 19 100BaseFX Port 15 20 100Ba...

Страница 5: ... 5 Mounting Dimensions Unit mm inch ...

Страница 6: ...wall as shown by the following illustrations STEP 1 Remove the aluminum DIN Rail attachment plate from the Moxa EDS 518A rear panel and then attach the wall mount plates with M3 screws as shown by the figure on the right STEP 2 Mounting Moxa EDS 518A on the wall requires 4 screws Use the EDS 518A with wall mount plates attached as a guide to mark the correct locations of the 4 screws The heads of ...

Страница 7: ...rs suitable for use in an ambient temperature of 93 C must be used for the Power Supply Terminal Provisions shall be made either in external to the apparatus to prevent the rated voltage being exceeded by the transients disturbances of more than 40 Wiring Requirements WARNING Do not disconnect modules or wires unless power has been switched off or the area is known to be non hazardous The devices ...

Страница 8: ...run signal or communications wiring and power wiring through the same wire conduit To avoid interference wires with different signal characteristics should be routed separately You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together Separate inp...

Страница 9: ...s form an open circuit when a user configured event is triggered If a user configured event does not occur the fault circuit remains closed Wiring the Redundant Power Inputs EDS 518A has two sets of power inputs power input 1 and power input 2 The top two contacts and the bottom two contacts of the 6 pin terminal block connector on EDS top panel are used for EDS two digital inputs The top and fron...

Страница 10: ...meaning of the Pinouts diagrams is straightforward The diagrams simply display the type of signal passing through each of the port s pins Cable Wiring Diagrams labeled Cable Wiring present standard cable wiring schemes for cables used to connect Moxa EtherDevice Switch s ports to other devices These diagrams display three pieces of information 1 When building your own cable refer to the pin to pin...

Страница 11: ...ing diagrams to connect Moxa EDS 518A s console port to your PC s COM port You may then use a console terminal program such as Moxa PComm Terminal Emulator to access Moxa EDS 518A s console configuration utility RJ45 10 pin Console Port Pinouts Pin Description 1 2 DSR 3 RTS 4 5 TxD 6 RxD 7 GND 8 CTS 9 DTR 10 RJ45 10 pin to DB9 F Cable Wiring RJ45 10 pin to DB25 F Cable Wiring ...

Страница 12: ...able used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port In what follows we give pinouts for both MDI NIC type ports and MDI X HUB Switch type ports We also give cable wiring diagrams for straight through and cross over Ethernet cables 10 100Base T x RJ45 Pinouts MDI Port Pinouts MDI X Port Pinouts 8 pin RJ45 Pin Signal 1 Tx 2 Tx 3 Rx 6 Rx P...

Страница 13: ...e I for full duplex transmission All you need to remember is to connect the Tx transmit port of device I to the Rx receive port of device II and the Rx receive port of device I to the Tx transmit port of device II If you are making your own cable we suggest labeling the two sides of the same line with the same letter A to A and B to B as shown by the following illustration or A1 to A2 and B1 to B2...

Страница 14: ...of the Turbo Chain Blinking The EDS 518A has become the Ring Master of the Turbo Ring or the Head of the Turbo Chain after the Turbo Ring or the Turbo Chain is down Off When the EDS 518A is not the Master of this Turbo Ring or is set as the Member of the Turbo Chain CPLR TAIL GREEN On When the EDS 518A coupling function is enabled to form a back up path or when it s set as the Tail of the Turbo Ch...

Страница 15: ... HTTP HTTPS Telnet SSH Syslog IPv6 LLDP IEEE 1588 PTP Modbus TCP SNMP Inform MIB MIB II Ethernet like MIB P BRIDGE MIB Q BRIDGE MIB Bridge MIB RSTP MIB RMON MIB Group 1 2 3 9 Interface RJ45 Ports 10 100 1000BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection Fiber Ports Optional 100BaseFX SC ST connector and 1000BaseSFP slot Console Port RS 232 10 pin RJ45 LED Indicators P...

Страница 16: ...50nm TX 1550nm RX 1310nm Max Tx 3 dBm 3 dBm 2 dBm 2 dBm 2 dBm 2 dBm Min Tx 9 dBm 9 dBm 8 dBm 8 dBm 3 dBm 3 dBm Rx Sensitivity 21 dBm 21 dBm 23 dBm 23 dBm 23 dBm 23 dBm Link Budget 12 dB 12 dB 15 dB 15 dB 20 dB 20 dB Typical Distance 10 km 10 km 20 km 20 km 40 km 40 km Saturation 1 dBm 1 dBm 1 dBm 1 dBm 1 dBm 1 dBm Power Input Voltage 24 VDC 12 to 45 VDC redundant inputs Input Current 24V 0 51A EDS...

Страница 17: ... 4 5 Surge Level 3 EN 61000 4 6 CS Level 3 EN 61000 4 8 EN 61000 4 11 EN 61000 4 12 Shock IEC 60068 2 27 Freefall IEC 60068 2 32 Vibration IEC 60068 2 6 WARRANTY 5 years Technical Support Contact Information www moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa...

Отзывы: