- 3 - 

EDS-405A-PTP Panel Layout (standard) 

 

 

 

 

 

1.

 

Terminal block for power input 
PWR1/PWR2 and relay output 

2.

 

System state LED 

3.

 

Power input 1 LED 

4.

 

Power input 2 LED 

5.

 

Fault LED 

6.

 

MSTR/HEAD LED 

7.

 

CPLR/TAIL LED 

8.

 

10/100BaseT(X) ports 

9.

 

Model name 

10.

 

Reset button 

11.

 

Grounding screw 

12.

 

Console port 

13.

 

DIP switches 

14.

 

Power 1, 2/Relay input 

15.

 

Screw hole for wall mounting kit 

16.

 

DIN rail kit 

 

 
 

 

Содержание EtherDevice EDS-405A-PTP Series

Страница 1: ...2014 Moxa Inc All rights reserved Reproduction without permission is prohibited P N 1802004050010 EDS 405A PTP Series Hardware Installation Guide Moxa EtherDevice Switch First Edition July 2014...

Страница 2: ...ed SCADA control network Package Checklist The Moxa EDS 405A PTP switches are shipped with the following items If any of these items is missing or damaged please contact your customer service represen...

Страница 3: ...output 2 System state LED 3 Power input 1 LED 4 Power input 2 LED 5 Fault LED 6 MSTR HEAD LED 7 CPLR TAIL LED 8 10 100BaseT X ports 9 Model name 10 Reset button 11 Grounding screw 12 Console port 13...

Страница 4: ...4 Mounting Dimensions unit mm Unit mm inch...

Страница 5: ...nel and then attach the wall mount plates with M3 screws as shown in the diagram at the right STEP 2 Mounting the EDS 405A PTP on the wall requires 4 screws Use the switch with wall mount plates attac...

Страница 6: ...transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together Keep input wiring a...

Страница 7: ...egative positive DC wires into the V V terminals respectively STEP 2 To keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the ter...

Страница 8: ...This will cause the STATE LED to blink once a second After depressing the button for 5 continuous seconds the STATE LED will start to blink rapidly This indicates that factory default settings have be...

Страница 9: ...he Ring Master ON Enables the default Ring Coupling ports ON Activates DIP switches 1 2 3 to configure Turbo Ring settings OFF This EDS will not be the Ring Master OFF Do not use this EDS as the ring...

Страница 10: ...nput PWR1 Off Power is not being supplied to power input PWR1 PWR2 AMBER On Power is being supplied to power input PWR2 Off Power is not being supplied to power input PWR2 FAULT RED On 1 The signal co...

Страница 11: ...X function allows users to connect the EDS 405A PTP s 10 100BaseTX ports to any kind of Ethernet device without needing to pay attention to the type of Ethernet cable being used for the connection Th...

Страница 12: ...ture 10 to 60C 14 to 140F 40 to 75 C 40 to 167 F for T models Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Part 15 Subpart B...