- 10 - 

 

WARNING 

This unit is a built-in type. When the unit is installed in another 
piece of equipment, the equipment enclosing the unit must 
comply with fire enclosure regulation IEC 60950/EN60950 (or 
similar regulation). 

 

 

 

WARNING 

Safety First!

 

Be sure to disconnect the power cord before installing and/or 
wiring your Moxa EtherDevice Switch. 
Calculate the maximum possible current in each power wire and 
common wire. Observe all electrical codes dictating the 
maximum current allowable for each wire size. 
If the current goes above the maximum ratings, the wiring could 
overheat, causing serious damage to your equipment. 

 

You should also pay attention to the following items: 

 

Use separate paths to route wiring for power and devices. If power 
wiring and device wiring paths must cross, make sure the wires are 
perpendicular at the intersection point. 
NOTE: Do not run signal or communications wiring and power wiring 
in the same wire conduit. To avoid interference, wires with different 
signal characteristics should be routed separately. 

 

You can use the type of signal transmitted through a wire to 
determine which wires should be kept separate. The rule of thumb is 
that wiring that shares similar electrical characteristics can be 
bundled together. 

 

Keep input wiring and output wiring separated. 

 

It is strongly advised that you label wiring to all devices in the system 
when necessary. 

Grounding Moxa EtherDevice Switch 

Grounding and wire routing help limit the effects of noise due to 
electromagnetic interference (EMI). Run the ground connection from the 
ground screw to the grounding surface prior to connecting devices. 

 

 

ATTENTION 

This product is intended to be mounted to a well-grounded 
mounting surface, such as a metal panel. 

 

 
 

 

Содержание ETHERDEVICE EDS-308

Страница 1: ... 2014 Moxa Inc All rights reserved P N 1802003083011 EDS 308 309 Hardware Installation Guide Moxa EtherDevice Switch Ninth Edition April 2014 ...

Страница 2: ...ed please contact your customer service representative for assistance Moxa EtherDevice Switch Hardware Installation Guide Moxa Product Warranty booklet Protective caps for unused ports Features High Performance Network Switching Technology 10 100BaseT X RJ45 100BaseFX SC ST type Multi Single mode IEEE802 3 802 3u 802 3x Store and Forward switching process type with 1024 address entries 10 100M Ful...

Страница 3: ...nputs PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 DIP switches 5 Power input PWR1 LED 6 Power input PWR2 LED 7 Fault LED 8 10 100BaseT X Port 9 TP port s 100 Mbps LED 10 TP port s 10 Mbps LED 11 Model Name 12 Screw holes for wall mounting kit 13 DIN Rail Kit ...

Страница 4: ...C 1 Grounding screw 2 Terminal block for power inputs PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 DIP switches 5 Power input PWR1 LED 6 Power input PWR2 LED 7 Fault LED 8 10 100BaseT X Port 9 TP port s 100 Mbps LED 10 TP port s 10 Mbps LED 11 Model Name 12 100BaseFX Port 13 FX port s 100 Mbps LED 14 Screw holes for wall mounting kit 15 DIN Rail Kit ...

Страница 5: ...n orifices 4 DIP switches 5 Power input PWR1 LED 6 Power input PWR2 LED 7 Fault LED 8 10 100BaseT X Port 9 TP port s 100 Mbps LED 10 TP port s 10 Mbps LED 11 Model Name 12 100BaseFX Port 13 Screw holes for wall mounting kit 14 DIN Rail Kit 15 100 Mbps LED for FX port 7 16 100 Mbps LED for FX port 8 17 100 Mbps LED for FX port 9 ...

Страница 6: ... DIP switches 5 Power input PWR1 LED 6 Power input PWR2 LED 7 Fault LED 8 10 100BaseT X Port 9 TP port s 100 Mbps LED 10 TP port s 10 Mbps LED 11 Model Name 12 100BaseFX Port 13 100 Mbps LED for FX port 14 Screw hole for wall mounting kit 15 DIN Rail Kit 16 100 Mbps LED for FX port 7 17 100 Mbps LED for FX port 8 18 100 Mbps LED for FX port 9 ...

Страница 7: ... 7 Mounting Dimensions Unit mm inch ...

Страница 8: ...8 309 on the wall as illustrated below STEP 1 Remove the aluminum DIN Rail attachment plate from EDS 308 309 s rear panel and then attach the wall mount plates as shown in the diagram below STEP 2 Mounting EDS 308 309 on the wall requires 4 screws Use the switch with wall mount plates attached as a guide to mark the correct locations of the 4 screws The heads of the screws should be less than 6 0 ...

Страница 9: ...onductors suitable for use in an ambient temperature of 93 C must be used for the Power Supply Terminal Provisions shall be made to prevent the rated voltage being exceeded by the transient disturbances of more than 40 Wiring Requirements WARNING Do not disconnect modules or wires unless the power supply has been switched off or the area is known to be non hazardous The devices may only be connect...

Страница 10: ... paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that w...

Страница 11: ...r which the corresponding PORT ALARM DIP Switch is set to ON is not properly connected If neither of these two conditions is satisfied the Fault circuit will be closed Wiring the Redundant Power Inputs The top two contacts and the bottom two contacts of the 6 contact terminal block connector on the EDS s top panel are used for the EDS s two DC inputs Top and front views of one of the terminal bloc...

Страница 12: ...rough Cable Wiring RJ45 8 pin to RJ45 8 pin Cross Over Cable Wiring 100BaseFX Ethernet Port Connection The concept behind the SC ST port and cable is quite straightforward Suppose you are connecting devices I and II Contrary to electrical signals optical signals do not require a circuit in order to transmit data Consequently one of the optical lines is used to transmit data from device I to device...

Страница 13: ...Switch has one Alarm Contact located on the top panel For detailed instructions on how to connect the Alarm Contact power wires to the two middle contacts of the 6 contact terminal block connector see the Wiring the Alarm Contact section on page 8 A typical scenario would be to connect the Fault circuit to a warning light located in the control room The light can be set up to switch on when a faul...

Страница 14: ...n the corresponding PORT alarm is enabled and the port s link is inactive Off When the corresponding PORT alarm is enabled and the port s link is active or when the corresponding PORT alarm is disabled 10M GREEN On TP port s 10 Mbps link is active Blinking Data is being transmitted at 10 Mbps Off TP Port s 10 Mbps link is inactive 100M TP GREEN On TP port s 100 Mbps link is active Blinking Data is...

Страница 15: ... aging algorithm causes the least used addresses to be deleted in favor of newer more frequently used addresses To reset the address buffer power down the unit and then power it back up Auto Negotiation and Speed Sensing All of EDS 308 309 s RJ45 Ethernet ports independently support auto negotiation for speeds in the 10BaseT and 100BaseTX modes with operation according to the IEEE 802 3u standard ...

Страница 16: ...309 Series redundant inputs Input Current 24VDC 1 1A EDS 308 Series EDS 309 Series Connection Removable 6 pin Terminal Block Overload Current Protection 1 1 A EDS 308 1 6 A EDS 308 M EDS 308 S EDS 308 MM EDS 308 SS EDS 309 3M Reverse Polarity Protection Present Mechanical Casing IP30 protection metal case Dimensions 53 6 x 135 x 105 mm W x H x D Weight 0 63 kg Installation DIN Rail Wall Mounting E...

Страница 17: ...rt Contact Information www moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 ...

Отзывы: