background image

 

- 8 - 

 

WARNING 

 

This equipment is intended to be used in a Restricted Access 

Location, such as a dedicated computer room. Access can 

only be gained by SERVICE PERSONS or by USERS who have 
been instructed about the fact that the metal chassis of the 

equipment is extremely hot and may cause burns.   

 

Service persons or users have to pay special attention and 
take special precaution before handling the equipment.   

 

Access is to be controlled through the use of a lock and key or 

a security identity system, controlled by the authority 
responsible for the location. Only authorized, well-trained 

professionals are allowed to access the restricted access 

location. 

 

External metal parts are hot!! Pay special attention or use 

special protection before handling. 

 

Wiring Requirements 

 

WARNING 

Safety First!

 

Be sure to disconnect the power cord before installing and/or 
wiring your Moxa AWK-3131. 

 

 

 

WARNING 

Safety First!

 

Calculate the maximum possible current in each power wire and 

common wire. Observe all electrical codes dictating the 

maximum current allowed for each wire size. 
If the current goes above the maximum ratings, the wiring could 

overheat, causing serious damage to your equipment. 

 

You should also pay attention to the following items: 

 

Use separate paths to route wiring for power and devices. If power 

wiring and device wiring paths must cross, make sure the wires are 
perpendicular at the intersection point. 

NOTE: Do not run signal or communications wiring and power wiring 

in the same wire conduit. To avoid interference, wires with different 
signal characteristics should be routed separately. 

 

You can use the type of signal transmitted through a wire to 

determine which wires should be kept separate. The rule of thumb is 
that wiring with similar electrical characteristics can be bundled 

together. 

 

Keep input wiring and output wiring separate. 

 

It is strongly advised that you label wiring to all devices in the system 

when necessary. 

 

www.hypercable.fr

 HYPERCABLE 

Содержание AWK-3131

Страница 1: ... 2 4 5 4 GHz Roaming de 20 ms pour les applications de video mobile associées au terminaux video audio full duplex wireless Frontline Guide d installation hardware Code Produit Radio WiFi MIMO AWK 3131 Hypercable 2013 ...

Страница 2: ...48 74 75 www hypercable fr 2 Table des matières 1 Produits périphériques 3 1 1 Casques de sécurité avec camera Video audio full duplex et WiFi intégrés 3 1 2 Pelicase Relais radio versatile universel LAN WAN 3 2 Hypercable contact 4 Manuel 5 1 5 L AWK 3131 et son alimentation 48 VDC ...

Страница 3: ...pas autre chose que le MobiRake Frontline HD Cette solution de Téléprésence durcie intégralement mains libres d une qualité Vidéo Audio et data exceptionnelle donnera au technicien sur son théâtre d opérations une assurance et une confiance inégalée dans son travail Entièrement connecté par radio sans aucun câble à tout type de réseau IP équipé de batteries a longue durée de vie MobiRake Frontline...

Страница 4: ...M M D S HYPERCABLE 81 Rue des Carrières ZA de la Ronze 69440 TALUYERS tel 33 4 78 48 74 75 www hypercable fr 4 4 2 Hypercable contact ...

Страница 5: ...r customer service representative for assistance AWK 3131 2 dual band omni directional antennas 2dBi RP SMA 2 4 5 GHz Cable holder with one screw 3 protective caps DIN rail kit Documentation and software CD Quick installation guide printed Warranty card Recommended SFP Accessories SFP 1G series SFP 1GSXLC Small form factor pluggable transceiver with 1000BaseSX LC 0 5 km 0 to 60 C SFP 1GSXLC T Smal...

Страница 6: ...ed by a DC power input or PoE Power over Ethernet The AWK 3131 will use whichever power source you choose Step 2 Connect the AWK 3131 to a notebook or PC Since the AWK 3131 supports MDI MDI X auto sensing you can use either a straight through cable or crossover cable to connect the AWK 3131 to a computer If the LAN LED indicator on the AWK 3131 port lights up it means the connection is established...

Страница 7: ...otebook A which is connected to the AWK 3131 After configuring the WLAN card establish a wireless connection with the AWK 3131 and open a DOS window on notebook B At the prompt type ping IP address of notebook A and then press the Enter key A Reply from IP address response means the communication was successful A Request timed out response means the communication failed In this case recheck the co...

Страница 8: ...tem LEDs PWR1 PWR2 PoE FAULT and STATE LEDs 5 LEDs for signal strength 6 WLAN LED 7 Ethernet or Fiber LED 8 RS 232 console port 9 LANs 10 100 1000 BaseT X RJ45 Port or 1000Base SFP 10 Main Antenna A 11 Main Antenna B 12 Model name 13 Screw hole for wall mounting Kit 14 DIN Rail mounting kit www hypercable fr HYPERCABLE ...

Страница 9: ... the DIN Rail attachment plate to the AWK 3131 make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN Rail into the slot just below the stiff metal spring STEP 2 The DIN Rail attachment unit will snap into place as shown below To remove the AWK 3131 from the DIN Rail simply reverse Steps 1 and 2 www hypercable fr HYPERCABLE ...

Страница 10: ...s a guide to mark the correct locations of the 3 screws The heads of the screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the wall mount panel between the wall and the screws NOTE Test the screw head and shank size by in...

Страница 11: ...WARNING Safety First Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowed for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment You should also pay attention to the following items Use separate paths to route wiring for power and devi...

Страница 12: ...ction from the ground screw to the grounding surface prior to connecting devices ATTENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel Wiring the Redundant Power Inputs The top two pairs of contacts of the 10 contact terminal block connector on the AWK 3131 s top panel are used for the AWK 3131 s two DC inputs Top and front views of the terminal...

Страница 13: ...onfigured event does not occur the Relay circuit will be closed Wiring the Digital Inputs The AWK 3131 has two sets of digital input DI1 and DI2 Each DI comprises two contacts of the 10 pin terminal block connector on the AWK 3131 s top panel You can refer to the Wiring the Redundant Power Inputs section for detailed instructions on how to connect the wires to the terminal block connector and how ...

Страница 14: ...ansmitted on differential TRD signal pairs over copper wires MDI MDI X Port Pinouts Pin Signal 1 TRD 0 2 TRD 0 3 TRD 1 4 TRD 2 5 TRD 2 6 TRD 1 7 TRD 3 8 TRD 3 RS 232 Connection The AWK 3131 has one RS 232 8 pin RJ45 console port located on the front panel Use either an RJ45 to DB9 or RJ45 to DB25 cable to connect the Moxa AWK 3131 s console port to your PC s COM port You may then use a console ter...

Страница 15: ...r is not being supplied from power input 1 PWR2 Green On Power is being supplied from power input 2 Off Power is not being supplied from power input 2 PoE Amber On Power is being supplied via PoE Off Power is not being supplied via PoE FAULT Red Blink slow Cannot get an IP address from the DHCP server interval 1 sec Blink fast IP address conflict interval 0 5 sec Off Error condition does not exist...

Страница 16: ...spatial streams DSSS with DBPSK DQPSK CCK OFDM with BPSK QPSK 16QAM 64QAM 802 11b CCK 11 5 5 Mbps DQPSK 2 Mbps DBPSK 11 Mbps 802 11a g 64QAM 54 48 Mbps 16QAM 36 24 Mbps QPSK 18 12 Mbps BPSK 9 6 Mbps 802 11n 64QAM 300 Mbps to BPSK 6 5 Mbps multiple rates supported Operating Channels central frequency US 2 412 to 2 462 GHz 11 channels 5 18 to 5 24 GHz 4 channels EU 2 412 to 2 472 GHz 13 channels 5 1...

Страница 17: ...54 Mbps 802 11a 87 dBm 6 Mbps 86 dBm 9 Mbps 85 dBm 12 Mbps 82 dBm 18 Mbps 80 dBm 24 Mbps 76 dBm 36 Mbps 72 dBm 48 Mbps 70 dBm 54 Mbps RX Sensitivity MIMO 802 11a n 68 dBm MCS15 40 MHz 70 dBm MCS7 40 MHz 69 dBm MCS15 20 MHz 71 dBm MCS7 20 MHz 802 11g n 68 dBm MCS15 40 MHz 70 dBm MCS7 40 MHz 69 dBm MCS15 20 MHz 71 dBm MCS7 20 MHz Protocol Support General Protocols Proxy ARP DNS HTTP HTTPS IP ICMP SN...

Страница 18: ... power inputs or 48 VDC Power over Ethernet IEEE 802 3af compliant Connector 10 pin removable terminal block Power Consumption 12 to 48 VDC 700mA max Reverse Polarity Protection Present Standards and Certifications Safety UL 60950 1 EN 60950 1 EMC EN 301 489 1 17 FCC Part 15 Subpart B Class B EN 55022 55024 Radio EN 300 328 EN 301 893 DSPR Japan Rail Traffic EN 50155 EN 50121 1 4 Environmental Not...