background image

Power

The STC30 Plus (v1.3) turns on once the power cord is securely placed into the back of the unit and is plugged into the power source.

Green

power light comes on.

Connecting Electric Screwdriver

Before connecting the electric screwdriver, make sure the little switch in the lower bottom right of the STC 30 Plus (v1.3) is
positioned in the proper setting (EF or K). See diagram below. Only operate tool in proper setting. 

1. Attach cord of the electric screwdriver to transformer. Make sure notch in plug lines up with the notch on the socket. Tighten knurled 

ground ring.

2. Select HIGH & LOW speed button. Select the appropriate speed for your application.

EF Mode

K Mode

Low = Output is 20VDC

Low = Output is 30VDC

High = Output is 30VDC

High = Output is 38VDC

3. Turn driver on and check for proper rotation. FOR-clockwise, REV-counterclockwise.
4. To apply torque, squeeze the lever (Push-to-Start models - place light downward pressure on the nose of the driver). The driver will 

automatically stop when the preset torque has been reached. 

Soft Start Mode

Press the "sT" button in the lower bottom right. The power light will blink once and turn 

Yellow

, which indicates that you are in Soft Start

mode. There are 4 different time settings for the Soft Start mode which are (0.5, 1.0 1.5 & 2.0 seconds). When you select this mode it starts
at 0.5 seconds. 

- Press the "sT" button again and the Yellow light will blink twice and the Soft Start time will increase to 1.0 seconds. 
- Press the "sT" button again and the Yellow light will blink three times and the Soft Start time will increase to 1.5 seconds. 
- Press the "sT" button again and the Yellow light will blink four times and the 

Soft Start time will increase to 2 seconds.

Quick Reminder

Green

Light = Operating in Standard mode

Yellow

Light = Operating in Soft Start mode

Red

Light = Double Hit mode

Double Hit Mode

The Double Hit mode is for very soft joint applications. When electric 
screwdrivers rundown a fastener quickly and the tool clutches off once
preset torque is achieved there can be some joint relaxation that can 
occur. The Double Hit mode has the electric screwdriver perform a 
second hit to stabilize the torque joint relaxation.

Joint relaxation is caused by the surface of part(s) embedding or by 
"soft parts" such as gaskets, plastics or spongy material, which 
collapses under the clamping force created in a torque condition. 

For Hard Joint applications there is no need to use the 
Double Hit mode.

Press the "sT" button continuously until the power light turns 

Red

The clutch of the electric driver works twice at the set torque under the
"Double Hit" mode. The Double Hit will increase the repeatability 
accuracy at the target torque by double checking.

Output Pin Connection

1: Motor (+)
2: Limit
3: Motor (-)
4: Drive
5: Ground

STC30 Plus (v1.3) Transformer

Rev 1.2

Select EF mode for operat-
ing the following drivers:

A4500-6500HT

SS3000-7000
CL2000-9000

EF150

EF

K

STC30

Plus

Select K *mode for operating
only the following
drivers:

K250-450

STC30

Plus

sT

Soft Start &
Double Hit
function

20/30V

30/38V

Make sure the switch is correct position before operating

your tool. Either EF or K mode.

* Do not operate any tool in this
mode except for the K-Series 
drivers.

1

5

4

3

2

Corporate Headquarters: 

1080 North 11th Street, San Jose, CA 95112    Phone: (408) 292-2214   Fax: (408) 292-2733

www.etorque.com

Page 1

Отзывы: