40
6.4
If the test result is NG (see Chart 16 in reference to the torque standard), MUST draw out or add a
little mount of oil and do the following steps:
6.4.1
Loosen the pulse unit housing by hands.
6.4.2
Loosen the greasing screw.
6.4.3
Draw out or add a little amount of oil.
6.4.4
Tighten
the
greasing
screw
back.
6.4.5
Tighten the pulse unit housing.
6.4.6
Test the torque again. If the test result is still NG, repeat the Steps 6.4.1 to 6.4.5 until
the
proper
torque
is
reached.
7.0 Pulse Unit Housing Assembly
Fix the housing by a vise. Turn the wrench in counter clockwise direction to tighten the pulse unit
housing.
Model No.
Air inlet pressure 85 PSI
N.M (at least)
FLEXS-40P 15.5
FLEXS-50P 25
FLEXS-60P 35
FLEXS-70P 55
FLEXS-90P 90
FLEXS-100P 125
FLEXS-130P 145
FLEXS-150P 210
FLEXS-30PX 12.5
FLEXS-40PX 14
FLEXS-50PX 22
FLEXS-60PX 28
Chart 16
Note: Handle rubber must
be covered by a piece of
cloth to avoid damage
Fig.114