PISTOL GRIP AIR SCREWDRIVER OPERATION MANUAL
Page | 1
Rev 2.0 (8/16/13)
SPECIFICATIONS
Note: The recommended air pressure: 80~90psi with 5mm (3/16") air hose and 70psi with 6.35mm (1/4") air hose
Torque adjustment:
1
Unscrew Torque Cover
2
Remove Torque Cover
3
Rotate torque adjustment
4
Rotate torque adjustment
clockwise to increase torque
counter-
clockwise to
decrease torque
OPERATIONS
1. Select a bit. Retract the bit collar. Insert the bit and release the retracted collar. To avoid
damage to fasteners,
, make
sure the proper bit is suitable for the head of the fastener.
2. Easy torque adjustment. Remove the Torque cover. Rotate the torque adjustment nut to set the torque limit. Turn
clockwise to increase torque and counter clockwise to decrease torque.
Note:
Higher Capacity
models are supplied with “
a "Torque Adjusting Device"
used for adjusting the tool for the
upper torque range capacity. Remove Torque Cover. Slide
Torque Adjusting Device
partially onto Torque Adjustment
nut.
3.
Ensure to utilize properly rated hose and fittings to ensure proper airflow and safe operation.
Securely attach air
hose
4.
Check forward/reverse selector to ensure desired rotation has been selected.
Slide torque adjustment switch (Right)
FOR-clockwise, (Left) REV-counterclockwise rotation. Slide torque adjustment switch (Right) FOR-clockwise, (Left)
REV-counterclockwise.
5.
Hold tool firmly or ensure the tool is properly secured in a torque arm before starting the fastening process. To start
the tool, engage the fastener and squeeze the lever. The tool will shut-off when the set value is achieved or when
the lever is released.
AIR SUPPLY
1. Air tools are adversely affected by moisture.
It is strongly recommended to utilize a Filter/Regulator at or near the
workstation to ensure stable air pressure at 80-90 psi for optimal performance and for removal of moisture and
other potential debris which can adversely effect the longevity and performance of an air tool.
2.
When using new air hose or air line, it is strongly recommended to first purge the line prior to connecting and
operating your tool.
3.
When disconnecting an air line, It is important to stow or store the air line in a manner which will prevent debris
from collecting in couplers or entering the hose or line.
4.
Inspect filter/regulators and drain air tanks and/or reservoirs to minimize potential issues related to moisture and
debris.
5.
Tools are designed for oil free operation, thus lubrication via the air supply is not required.
Model
No.
Free
Speed
Weight
O.A.L
Dia.
Air
Consumption
Torque range
(soft joint)
rpm g inch
inch l/s
lbf-in Nm
XP35P 2,200
690
7.1
1.3
4.7 2.6-17.4 0.3-2.0
XP41P 1,000
690
7.1
1.3
4.7 4.3-30.4 0.5-3.4
XP48P 1,700
1030
8.5
1.5
9.2 6.1-43.4 0.7-4.9
XP55P 1,000
1030
8.5
1.5
9.2 10.4-65.1 1.2-7.4
XP65P 300
1150
8.5
1.5
9.2 26.0-156.2 2.9-17.6