www.mountztorque.com
– 1080 N 11
th
St - San Jose CA 95112–- 408.292.2214
5
When the reading on the torque meter master is lower than the setting on the tool, increase the calibration value more
than 100(%) which is basic on production. To increase the output torque 5% more, key in 105(%). The calibration value
works through whole range of torque. It will be refreshed and stored in the memory of the tool so it can be still effective
when using the tool on another controller.
NOTE: Different Torque Master Devices will provide different results. Make sure you always use the same ISO17025
Torque Tester Master Device with the same accessories and testing conditions: RDA, Tool Speed, Tester Filter Setting,
Torque Arm, etc.
Standard test condition on factory calibration used by Mountz
Rundown screw size, joint type and filter
MDC Tool: Set Auto speed on torque setting
Tool
Rundown adaptor
Low Pass Filter
MD2601
M3 Allen, Hard joint
200Hz
MD2602, MD2604
M3 Allen, Hard joint
500Hz
MD2611, MD2616
M4 Allen, Hard joint
500 Hz
MD3201
M3 Allen, Hard joint
200Hz
MD3202
M3 Allen, Hard joint
500Hz
MD3204
M4 Allen, Hard joint
500 Hz
MD3211, MD3216
M6 Allen, Hard joint
500 Hz
MD3236, MD3264
M12 Allen, Hard joint
500 Hz