When the reading on the torque meter master is lower than the setting on the tool, increase the calibration value more 
than 100(%) which is basic on production. To increase the output torque 5% more, key in 105(%). The calibration value 
works through whole range of torque. It will be refreshed and stored in the memory of the tool so it can be still effective 
when using the tool on another controller.  
 
NOTE: Different Torque Master Devices will provide different results.  Make sure you always use the same ISO17025 
Torque Tester Master Device with the same accessories and testing conditions: RDA, Tool Speed, Tester Filter Setting, 
Torque Arm, etc. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Standard test condition on factory calibration used by Mountz  

 

Rundown screw size, joint type and filter 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
MDC Tool:  Set Auto speed on torque setting 
 

 
 

Tool 

Rundown adaptor 

Low Pass Filter 

MD2601 

M3 Allen, Hard joint 

200Hz 

MD2602, MD2604 

M3 Allen, Hard joint 

500Hz 

MD2611, MD2616 

M4 Allen, Hard joint 

500 Hz 

MD3201 

M3 Allen, Hard joint 

200Hz 

MD3202 

M3 Allen, Hard joint 

500Hz 

MD3204 

M4 Allen, Hard joint 

500 Hz 

MD3211, MD3216 

M6 Allen, Hard joint 

500 Hz 

MD3236, MD3264 

M12 Allen, Hard joint 

500 Hz 

Содержание E-DRIV MD-Series

Страница 1: ...www mountztorque com 1080 N 11th St San Jose CA 95112 408 292 2214 1 Revision 1 1 July 05 2017 E DRIV MD Series DC Torque Control System Calibration Procedure...

Страница 2: ...amaged cords increase the risk of electric shock When operating a power tool outside use an outdoor extension cord marked W A or W These cords are rated for outdoor use and reduce the risk of electric...

Страница 3: ...orly maintained tools Use only accessories that are recommended by the manufacturer for your model Accessories that may be suitable for one tool may become hazardous when used on another tool SERVICE...

Страница 4: ...justed when customer validates tool with their torque master equipment and there is a difference between tool and master readings This calibration is also performed when Mountz services the tool as pa...

Страница 5: ...Devices will provide different results Make sure you always use the same ISO17025 Torque Tester Master Device with the same accessories and testing conditions RDA Tool Speed Tester Filter Setting Torq...

Страница 6: ...h St San Jose CA 95112 408 292 2214 6 Tool Compensation Torque compensation using controller panel Tool Compensation Torque compensation using ParaMon software Total adjustable range is 20 80 to 120 f...

Страница 7: ...ur tool s craftsmanship and our ability to provide solutions to both common and uncommon torque applications We perform calibrations in accordance with ANSI NCSL Z540 Mountz is dedicated solely to the...

Отзывы: