[30]
User Guidelines
– TCU-200
12-06-2019
Vers. 003
Full scale return transducer drive pump.
Value in bars.
NO CHANGE WITHOUT CONSULT THE MANUFACTURER
Maximum process start time.
Value in minutes.
NO CHANGE WITHOUT CONSULT THE MANUFACTURER
Contact NO or NC input level.
Not modifiable by the user.
Leak monitoring.
Activate or not the monitoring control. On-OFF.
10
Leak monitoring
Default leak monitoring is enabled, and can be disabled by LM parameter in the St-8 menu.
The process works as follows: Water / oil TCU units:
When process start, letter L (zone B) will flash. When the TCU pump is more than 2 minutes running in continuous, (this
will mean that there is no demand for water/oil in the process), the letter L will stop flashing.
From this moment, leak monitoring is enabled. Leak detection:
Once monitoring is enabled (in water process) if we demand for water more than once in an hour, or repetitive demands
on for 4 consecutive hours, in zone A message is displayed
Will activate the audible alarm by turning off the pump and heating temperature control unit.
Once the user has disconnected the pump switch and confirmed the alarm by pressing
Содержание TCU-200
Страница 10: ... 10 User Guidelines TCU 200 12 06 2019 Vers 003 3 2 Rear view ...
Страница 19: ... 19 User Guidelines TCU 200 12 06 2019 Vers 003 7 Display and Parameter settings Zone A Zone B ...
Страница 38: ... 38 User Guidelines TCU 200 12 06 2019 Vers 003 17 Electrical diagram ...
Страница 39: ... 39 User Guidelines TCU 200 12 06 2019 Vers 003 18 Water Circuit Diagram ...
Страница 40: ... 40 User Guidelines TCU 200 12 06 2019 Vers 003 19 Control Circuit diagram ...
Страница 41: ... 41 User Guidelines TCU 200 12 06 2019 Vers 003 20 Components and spare part list ...