DRY CONTACTS MANUAL 

TECHNICAL DOCUMENT 

1) INPUT DESCRIPTION 

The lock has three digital input (active low) to open it controllable by shorting the pins to GND with a dry contact. 
If  an  open  collector  device  is  used,  make  sure  the  polarity  is  correct  (i.e.  collector/drain  connected  to  IN  – 
emitter/source connected to GND) 

 
IN1 = open the lock  
IN2 = close the lock 

IN3 = open followed by an automatic closure 
The input signal must be a pulse. 
 
 

1.a) HOW TO OPEN THE LOCK 

Send a pulse (duration from 500 to 1500 ms) to the IN input you will get the full opening of the lock (latches and latch 
bolt). The closing will take place automatically when you close the door. 
 

2) OUTPUT DESCRIPTION 

Five digital outputs of the type "open collector" provide the following information: 
OUT1 : state latch bolt 

=> (OPEN = outside  

 

; CLOSE = inside) 

OUT2 : state latches 

=> (OPEN = not outside    

; CLOSE = outside) 

OUT3 : state door 

=> (OPEN = open  

 

; CLOSE = close ) 

OUT4 : error 

 

=> (OPEN = all is OK 

 

; CLOSE = error )  

OUT5 : battery status 

=> (OPEN = charged 

 

; CLOSE = low) 

 
Each output is TTL compatible (5V dc) and must comply with the following electrical requirements: 
 

ABSOLUTE MAXIMUM RATINGS 

Io sink max. 

<= 20 

mAdc 

Vo open max. 

<= 6 

Vdc 

Vo saturation max. 

<= 0,8 

Vdc 

 

These  outputs  are  available  only  when  the  lock  is  awake,  otherwise  they  are  all  "open"  (N.O.)  to  reduce 
consumption of energy. 

 

To wake up the lock without opening it, piloting the input IN with a short pulse duration from 50 to 100 msec., the 
status will be available immediately after the pulse, and the lock will remain awake for an additional 3 sec. (TIMEOUT 
period).  

 
N.B.: The times indicated in charts are only for examples. 

Input signal IN (continuous line = 50 ms ; dashed line = 100 ms)

0

1

0

250

500

750

1000

1250

1500

1750

2000

2250

2500

2750

3000

mSec

Level

 

All outputs represent their states in the timeout interval

0

1

0

250

500

750

1000

1250

1500

1750

2000

2250

2500

2750

3000

mSec

Level

 

 

 
 