Ps34001b_oi_e.doc / 19.11.15
Page 34 / 43
8.4
Error Messages
Upon detection of an error, the drive remains in a closed-loop standstill at the actual position.
Output “Error” switches to high and the unit displays a flashing error message “Error…”
indicating the error number.
To clear an error state either set “Reset” command or cycle the power supply of the unit.
Please note that the unit will immediately return to the error state if the cause for the error has
not been eliminated.
Error No.
Error Description
Error 0
The reason for the error has been rectified (e. g. power supply voltage recovered
above minimum level) but the error has not yet been cleared by input “Reset”.
Error 1
Power Low:
The power supply voltage is too low.
This error is reset automatically when the power supply voltage recovers and
exceeds the minimum power supply voltage level.
Error 2
Val. Range exceed:
An internal parameter value is out of range
Error 3
Invalid Position Setting:
At loop operation (mode 3) the branch address does not refer to a new position
but again to a branch address.