F02
Range
Default
F02.013
Max. Master Frequency:
Sets the expected maximum input frequency on the
Master encoder input, i. e. the line encoder frequency at
maximum line speed. You should add a 10% reserve to
the real maximum frequency. The unit will not process
frequencies higher than this setting.
0.1
…300000.0
(Hz)
30000.0
F02.014
Cut Window:
Sets a tolerance window scaled in length units around
the cutting position where the carriage must be before
the “Ready to cut” signal is switched on.
We recommend setting this window not too small,
because no cut will be activated when for any reasons
we do not reach this window (carriage will then run to
the front stop).
1 … 99
50
F02.015
Sync. Samples:
Filter for the cut window. The purpose of this parameter
is to ensure that the carriage has reached a stable
position within the cut window and does not leave the
window again right after the “ready to cut”
-output has
been switched on. Sync Samples = n means that during
n consecutive control cycles the carriage must be inside
the win
dow, before the “ready to cut”
-signal is
switched on.
This function should only be used for systems with poor
dynamic performance. Please note that too high settings
of this parameter may cause the controller to never set
the “ready to cut”
-signal.
Recommended setting: 1
1 … 9999
1
F02.016
Home Window:
Sets a window scaled in length units around the home
position of the carriage.
The output “Home” indicates by High state that the
carriage position is inside this window.
The unit will go to error state when a new cutting cycle
would need to start before the carriage has returned to
the home window from the previous cut.
1 … 999
100
F02.017
Jog Speed:
Speed setpoint in Volt for Jog operations by use of input
“Jog forward” or “Jog reverse”.
0.01 … 10.00
1.00